| DLS INSPECTION REPORT | |
| Client(s): | Xavier |
| Property address: | 503 pennsylviania NE |
| Inspection date: | Friday, April 28, 2006 |
This report is the exclusive property of DLS HOME INSPECTIONS and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.
![]() | Safety | Poses a risk of injury or death |
![]() | Major defect | Correction likely involves a significant expense |
![]() | Repair/Replace | Recommend repairing or replacing |
![]() | Repair/Maintain | Recommend repair and/or maintenance |
![]() | Maintain | Recommend ongoing maintenance |
![]() | Evaluate | Recommend evaluation by a specialist |
![]() | Monitor | Recommend monitoring in the future |
![]() | Serviceable | Item or component is in servicable condition |
![]() | Comment | For your information |
Structural Pest Inspection Concerns
Items marked with the following icons relate to the structural pest inspection
![]() | Infestation | Evidence of infestation of wood destroying insects or organisms (Live or dead insect bodies, fungal growth, etc.) |
![]() | Damage | Damage caused by wood destroying insects or organisms (Rot, carpenter ant galleries, etc.) |
![]() | Conducive conditions | Conducive conditions for wood destroying insects or organisms. (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.) |
Table of Contents
General information
Exterior
Roof
Garage
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Kitchen
Bathrooms
Interior rooms
| General information | Return to table of contents |
| Exterior | Return to table of contents |
![]() ![]() ![]() |
1) there is some minor cracking and small holes in stucco which should be patched to avoid penetration of water in the future
|
|||||
![]() ![]() ![]() |
![]() |
2) There ar seperations on some of the walls surrounding the yard and should be evaluated and sealed to prevent water damage penetration
|
||||
![]() ![]() |
3) Paint is needed around back door and above garage door
|
|||||
![]() |
4) Minor cracks were found in one or more sidewalk or patio sections. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client(s) may wish to have repairs made or have cracked sections replaced for aesthetic reasons. |
| Roof | Return to table of contents |
![]() ![]() |
![]() |
5) One or more parapet wall top surfaces have cracks and should be sealed to prevent water intrusion. A qualified contractor should evaluate and repair as necessary.
|
||||
![]() |
![]() |
6) A qualified roofing contractor should evaluate and apply a new roof coating as necessary in the future. Typically this is done every four to five years.
|
||||
![]() ![]() ![]() |
7) There are two skylights on the roof , these are not leaking and appear to be sealed but can be a source of leaks in the future ,you should monitor and call a contractor if you notice any water leaking to avoit future problems
|
|||||
![]() |
8) VENTILATION
|
| Garage | Return to table of contents |
![]() |
9) The garage door was evaluated and all saftey features worked at the time of the inspection. |
| Electric service | Return to table of contents |
10) Service panel photos
|
||||||
11) Minor crack in garage floor
|
| Water heater | Return to table of contents |
![]() ![]() |
12) The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be approaching this age and may need replacing at any time. Recommend budgeting for a replacement in the near future. | |||
![]() ![]() |
13) The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be at this age or older and may need replacing at any time. Recommend budgeting for a replacement in the near future.
|
| Heating and cooling | Return to table of contents |
![]() ![]() ![]() |
14) The furnace did not respond when its controls were operated. This system was not fully evaluated. The client(s) should consult with the property owner(s) as to how it operates and have a qualified heating and cooling contractor evaluate and make repairs if necessary. The owners are repairing the electric igniter as per the Gas company and will call me to re evaluate when contractor is finished
|
|||
![]() |
15) The furnace was shut off at the time of the inspection. For example, the gas supply was shut off, the pilot light was out, and/or the electric supply was turned off. As a result, the inspector was unable to fully evaluate this unit. | |||
![]() |
16) Swamp cooler was not on at time of inspection and could not be evaluated
|
| Plumbing and laundry | Return to table of contents |
![]() |
17) Neither the clothes washer nor dryer were operated or evaluated. They are excluded from this inspection. | |||
![]() |
18) Gas meter at it's location
|
| Kitchen | Return to table of contents |
![]() |
19) All apliances were on and tested and were working at time of inspection ,there were no leaks or problems at time of inspection. all cabinets and drawers were working |
| Bathrooms | Return to table of contents |
![]() ![]() ![]() ![]() |
20) One or more electric receptacles have reverse-polarity wiring, where the hot and neutral wires are reversed. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs as necessary. (The two bathroom outlets are reversed wired the GFCI for both bathrooms is located in the master bath and they are on the same circuit tested GFCI and both outlets are reversed and both are inactive when GFCI is tripped) |
|||||
![]() ![]() |
![]() |
21) Tile and/or grout around one or more bathtubs is damaged or deteriorated. For example, deteriorated or missing grout, cracked, missing or loose tiles, etc. A qualified contractor should evaluate and repair tile and/or grout as necessary.
|
||||
![]() ![]() |
22) Broken toilet seat in master bathroom | |||||
![]() |
23) One or more shower drains are clogged or drain slowly. Drain(s) should be cleared as necessary, and by a qualified plumber if necessary. The drain in the halway bathroom tub drains slowly |
|||||
| 24) counter top in master bath has a "burn mark" or discoloring at sink |
| Interior rooms | Return to table of contents |
![]() ![]() ![]() |
25) Inspector could not open back security door because there was no key available this door has a keyed deadbolt and can be a saftey hazzard in case door is needed for an emergency exit | |
![]() |
26) All celing fans,lights and doors checked out and were working at time of inspection also a representative number of windows and blinds were operated and were working at time of inspection. |
![]() Photo 12 front door and entry OK |