Iowa State Home Inspection's

Website: http://www.ishomeinspections.com
Email: dave@ishomeinspections.com
Phone: (515) 783-8241

 

Property Inspection Report
Client(s): John and Jane Doe
Property address: 123 Main Street
Your Town, Iowa
Inspection date: Sunday, April 06, 2008
This report published on 11/14/2008 3:28:13 AM CST

View summary page

Thank you for choosing Iowa State Home Inspection's. Experience and Integrity at work for your peace of mind.

This inspection was performed by NACHI Certified Home Inspector Dave Reynolds, and was conducted under the highest standards in our profession and in compliance with the Standards of Practice set forth by The National Association of Certified Home Inspectors.

Please pay attention to important information and concerns contained in this report. It is always recommended that a qualified contractor review, advise and estimate for all concerns within this report. Thank you.

If you have any questions regarding this report please call Dave Reynolds at (515) 783-8241

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
Major DefectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
MaintainRecommend ongoing maintenance 
MonitorRecommend monitoring in the future 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Roof and Ventilation
Walls Windows and Doors
Exterior and Landscaping
Attached garage
1st Bathroom
Main Bathroom
Master Bath
General Interior
Fireplace
Attic
Kitchen and Laundry
Heating
Air Conditioning
Domestic Water Heater
Electric Panel
Plumbing
Basement
Safety Concerns
 
General information Return to table of contents
Overview: Residential area
Report number: 003122
Present during inspection: Buyer, Realtor
Age of building: 30+
Type of building: Single family
Weather conditions: Cloudy
Temperature: Cool
Ground condition: Damp
Foundation type: Basement
 
Roof and Ventilation Return to table of contents
Roof inspection method: Viewed from eaves on ladder, Viewed from ground
Roof type: Cross gable
Roof covering: Asphalt or fiberglass composition shingles
Layers noted: Single Layer
Estimated age of Roof: older, near the end of it's life.
Roof Requires: Monitor regularly
Roof Penetrations: Chimney, Vent Pipes, Roof Vents
Gutter material: Aluminum
Downspout material: Aluminum
Chimney appears to be built: within the interior of house
Spark arrester/rain cap: noted
Chimney made of: Metal
Flue Liner: noted at top of chimney
Visible Roof Ventilation: Roof Vents


1) Trees are overhanging roof and are within 10 feet of roof vertically. Recommend pruning trees so they're at least 10 feet above roof, or don't overhang the roof.

Photo 3  
 

2) Significant amounts of organic debris (leaves, needles, etc.) are on the roof. This condition can cause roof leaks and premature aging. Recommend cleaning roof.

Photo 11  
 

3) While no roof leaks were visible at the time of inspection, the roof is nearing the end of it's life and should be monitored on a regular basis. Some areas show signs of uneven roof surfaces most likely caused by sagging roof decking. Monitor for leaks and repair/replace as needed.

Photo 1  

Photo 2  

Photo 27  
 
 
Walls Windows and Doors Return to table of contents
Apparent wall structure: Wood frame
Wall Covering Material: Brick, Wood
General Condition of Covering: t-111 siding is buckled in areas. Brick siding has cracks that will need to be re pointed.
Trim: Wood
Trim Condition: Acceptable
Doors: Operated well
Windows: Storms, Screens, Some storms and screens are missing
Primary service type: Underground
Service size: 200 Amp Aluminum
Meter amperage (amps): 200
Service voltage (volts): 3 phase 120-240
4) Areas of trim and siding are decayed and will need repair/replacement. Consult a qualified contractor for estimate of repair.

Photo 14  

Photo 18  

5) Siding is buckling. Areas of replacement are needed. Consult a qualified contractor for estimate of repair.

Photo 21  
 

6) The brick fascia/siding along with the brick column by the garage needs to be repaired. Mortar has deteriorated. Trim is also missing. Consult a qualified contractor for estimate of repair.

Photo 4  

Photo 15  

Photo 16  

Photo 17  

7) Vegetation growing on or against a building can cause serious problems in a home. Vegetation will hold moisture that can and will cause mold and rot if not removed. It will cause deterioration to brick and mortar along with all concrete type products. Mold, rot and deteriorated surfaces may be hidden. ALL vegetation growing on or within 2 feet of a structure should be removed and the structure inspected for damage.

Photo 4  
 

8)   200 amp electric service.

Photo 5  
 
 
Exterior and Landscaping Return to table of contents
Exterior of foundation walls: block
Exterior Foundation Exposure: Approximately 1 foot
Exterior foundation, observed: small cracks, deteriorated surfaces
Window Wells: Metal
Grading within 6 feet of house: About level
Grading beyond 6 feet of house: About level
Driveway material: Poured in place concrete
Driveway condition: large cracks
Walkway to front entry: concrete
Condition of walkway: Acceptable but has minor cracks or breaks
Deck Location: Rear of house
Deck material: wood
Steps down to grade: One step to grade
Visibility under deck: Two foot and clear view
Support column under deck: wood-Joist rotted
Condition of the support columns: Acceptable
9) Wood frame around many exterior windows are decaying. Some have been repaired. Expect to replace windows in the near future. Consult a qualified contractor for evaluation and estimate of repair.

Photo 12  

Photo 13  

10) Driveway is cracked due to settling. The driveway will need replacing. Consult a qualified contractor for estimate of repair.

Photo 28  

Photo 35  

11) The rear deck has a floor joist that is rotted, providing no support. The remainder joists are bowing due to the lack of a center support. Recommend replacing all rotted wood and adding center support. Consult a qualified contractor for estimate of repair.

Photo 9  

Photo 22  

Photo 23  
Broken and rotted joist.

Photo 24  
Several joist are sagging.
Additional support needed.

Photo 25  
 

12) Concrete slab on the side of garage has settled toward the house. This condition is causing rain water to drain against the foundation. Recommend replacing/removing the slab. Consult a mason for advise.

Photo 19  
 

13) Areas of the block foundation need re pointing. Consult a mason for repair.

Photo 26  
 

14) Replace window well covers.

Photo 10  
 

15) One of, if not the most important part of the exterior landscape of the structure is the grade around the perimeter. Improper grade will cause water problems in the basement and will damage the foundation and in some cases the footings of the foundation. These areas in most cases are not visible to the eye. Always grade away from the house.

Photo 6  
 

16)   Exterior

Photo 6  

Photo 8  

Photo 20  
 

17)   Main entry

Photo 29  

Photo 30  
 
Attached garage Return to table of contents
# of Bays: Two
Situated: Side by side
Visibility limited by: stored items
Floor: Concrete
Floor Condition: Small cracks
Walls: Wood Frame
Walls: Drywall covered
Automobile Doors #: One
Style: Overhead
Doors operated: easily
Rollers making clicking sound: No
Lift Cable: Good Condition
Is the overhead door balanced: Yes
Springs: Good Condition
Electric Car Door Openers: One
Operated: Yes, and operated properly
Photo electric device: noted
Non-Automobile doors to interior: Two
Interior door: Wood
Windows: None noted
Overhead: Closed in ceiling
Condition of Roof Underside: Old stains and repair
18) Overhead garage door is decayed along the bottom. Several screws and braces are missing. Repair/replace as need. Consult and overhead door company for an estimate of repair.

Photo 31  

Photo 32  

Photo 33  
 

19) The garage-house door is not made of metal, not fire-rated and not of solid-core construction. A metal fire rated door would be a better choice.
20)   Water stain and repair on garage ceiling.

Photo 34  
 
 
1st Bathroom Return to table of contents
Bathroom 1: Partial
Location: Lower
Tub: None Noted
Jacuzzi noted in bath: No
Surround: other
Surround condition: Acceptable
Sink Type: Vanity
Toilet: flushed
Toilet Condition: Acceptable
Floor: Carpet
Floor Condition: Acceptable
Leaks: none noted
Caulking appears: Intact
Ventilation: Window
Number of outlets: One
Ground Fault Interrupter outlets: No
21) No ground fault circuit interrupter (GFCI) outlets installed. GFCI outlets help prevent electric shocks in areas that may have water present. Recommend having a qualified electrician install one or more GFCI outlets, especially over counter tops and around sinks.

Photo 37  
 
 
Main Bathroom Return to table of contents
Main Bathroom: Full
Location: Second floor hall
Shower: with tub
Tub: Built in
Jacuzzi noted in bath: No
Surround: Plastic
Surround Condition: Acceptable
Number of sinks?: One
Sink Type: Vanity
Toilet: flushed
Toilet Condition: Acceptable
Floor: Vinyl
Floor Condition: Acceptable
Leaks: none noted
Caulking appears: Intact
Ventilation: Window, Fan
Outlets: One
Ground Fault Interrupter Outlets?: No
22) No ground fault circuit interrupter (GFCI) outlets installed. GFCI outlets help prevent electric shocks in areas that may have water present. Recommend having a qualified electrician install one or more GFCI outlets, especially over counter tops and around sinks.

Photo 48  

Photo 49  
 
Master Bath Return to table of contents
Bathroom 1: Full
Shower: Stall
Tub: None Noted
Jacuzzi noted in bath: No
Surround condition: Acceptable
Sink Type: Vanity
Toilet: flushed
Toilet Condition: Acceptable
Floor: Vinyl
Floor Condition: Acceptable
Leaks: none noted
Caulking appears: Intact
Ventilation: Window, Fan
Number of outlets: One
23) No ground fault circuit interrupter (GFCI) outlets installed. GFCI outlets help prevent electric shocks in areas that may have water present. Recommend having a qualified electrician install one or more GFCI outlets, especially over counter tops and around sinks.

Photo 52  

Photo 53  
 
General Interior Return to table of contents
Ceilings appear to be made of: Drywall
Ceiling Style: Flat, Sloped
Ceiling Condition: Good
Major Defects: None Noted
Mostly walls appear to be made of:: Drywall
Major defects were noted: No
Floor coverings are mostly: Wall to wall carpet
When bounced on: a normal amount of bounce was noted
Generally floors feel: Level
Mostly the doors are the following types: Hollow core
General door condition: Acceptable
Windows were mostly observed to be: Double hung, Casement
Insulated noted in: Most
Appear made of: Wood
Random Tested: Yes
Skylights: Appear fixed
Skylight leaks: none noted
Stairs: between living levels
Stairs condition: Acceptable
24)   General interior

Photo 38  

Photo 39  

Photo 41  

Photo 42  

Photo 43  

Photo 47  

Photo 50  

Photo 51  
 
Fireplace Return to table of contents
Fireplace Location: Den
Fireplace: Metal prefabricated
Inspected: Ash in bottom
Damper: Opened and closed
Flue Liner: Noted
25) Recommend having the fireplace and chimney cleaned before use. Some firebrick has cracked and deteriorated. Consult a fireplace specialist for estimate.

Photo 40  

Photo 54  
 
Attic Return to table of contents
Attic access: Scuttle hole
How observed: Limited viewing, looked thru opening only
Roof system: truss system
Roof decking: plywood
Moisture penetration: Mold noted
Attic floor framing: wood
Attic floor system: catwalk down the middle
Attic Ventilation: Gable Vents-roof
Insulation material: Fiberglass loose fill
Insulation location: floor
26) Mold was noted in the attic space. Attic needs additional ventilation. Recommend having a mold remediation company evaluate for best method of treatment. Consult a qualified contractor for estimate.

Photo 62  

Photo 63  

Photo 64  

Photo 65  

Photo 66  

Photo 67  

Photo 68  

Photo 69  
 
Kitchen and Laundry Return to table of contents
Cabinets: Wooden
Opened and closed and found: seemed to function
Cabinets secure: yes
Counter Tops: Plastic Laminate
Securely fastened: yes
Kitchen Floor: Sheet Goods
Dishwasher: Noted
Operated Dishwasher: yes
Dishwasher age: midlife
Kitchen Sink: Plastic
Ran water and found: No leaks
Disposal: In Sink Erator
Refrigerator: Noted
Refrigerator in use during inspection: yes
Age: Older
Range type: Free standing
Age: Older
Operated and found: All burners working
Operated oven and found: gave off heat
Ventilation: Fan vented outside
Number of Regular outlets in kitchen: Four or more
Washing Machine: Noted
Location: basement
Observed: Connections for water and drain, Connections for electric
Operated: In use during inspection
Dryer: Noted
Dryer age: Older
Vented to: Exterior
Operated: In use during inspection
27) No ground fault circuit interrupter (GFCI) devices (outlets or circuit breakers) are visible for the kitchen. GFCI devices help prevent electric shocks in areas that may have water present. Recommend having a qualified, licensed electrician install GFCI protection for outlets, over counter tops and around sinks.

Photo 36  

Photo 44  

Photo 45  
 
 
Heating Return to table of contents
Heating System Brand Name: Trane
Apparent age of unit: Midlife
Heating system type: Forced hot air
System has # of Zones: One
Fuel Source: Electricity
Combustion Air Supply: Interior
When thermostats were turned on, the system: fired or gave heat
Flue pipes: Noted
Distribution system: Ductwork
Heat distribution: In most rooms
28) Recommend that this system be serviced every 2 years in the future by a qualified heating and cooling technician.

Photo 56  
 
 
Air Conditioning Return to table of contents
Central Cooling: Central Air
Brand name: Heil
Status: Operated
Approximate age of system: 20
A/C energy source: Electric
Air conditioning type: Split system
29)   Older A/C operated and provided 62 degree air at the time of inspection.

Photo 7  
 
 
Domestic Water Heater Return to table of contents
Estimated age: Newer
Type: Tank
Energy source: Electricity
Capacity (in gallons): 50
Brand: Whirlpool
Safety relief valve: was noted
Safety extension: was noted
Supply shut off valve: Noted
Drain discharge to:: Floor
Rust or Corrosion: was not noted
Tested hot water: Hot water was received at faucets
30)   Newer hot water tank.

Photo 57  
 
 
Electric Panel Return to table of contents
Location of Main Panel: Basement
Location of main disconnect: Breaker at top of main panel
Primary service overload protection type: Circuit breakers
Service conductor material: Aluminum
Main disconnect rating (amps): 200
Branch circuit wiring type: Non-metallic sheathed ("Romex")
Solid strand aluminum branch circuit wiring present: Can't verify
Double tapped breakers: No
Room for additional circuit breakers: No
Missing Circuit Breaker Covers: No
Grounding observed to:: Plumbing
Grounding connection feels: secure
31)   200 amp electric service.

Photo 55  
 

32)   Panel cover removed and inspected.

Photo 71  
 
 
Plumbing Return to table of contents
Water service: Public
Main entry pipe material: Copper
Location of main water meter: Basement
Location of main water shutoff: Next to meter
Interior supply pipes: Copper
With multiple fixtures running observed: Acceptable decrease in flow
Waste System Pipes: Plastic, Cast Iron
Main waste line clean outs: noted
Vent pipe observed on roof: Yes
33)   No visible plumbing leaks at the time of inspection.

Photo 58  
 
 
Basement Return to table of contents
Basement: Readily accessible
Viewed by: walked throughout
Foundation walls: hidden from view
Could not see foundation walls because of: drywall
Ceiling framing: Hidden from view
Interior of foundation wall: block-Hidden from view
Basement floor: concrete, carpeting
Water stains observed on: none noted
General area dampness: dehumidifier noted
Ventilation: Windows
Pier or support post material: Bearing wall
Support columns condition: appear intact
Floor drainage: had safety covers
Sump pump: None noted
Floor structure above: Solid wood joists
Insulation material underneath floor above: Fiberglass roll or batt
Beam material: Solid wood
Windows: Metal
34) There were no visible signs of water infiltration in the basement area. Due to the basement being mostly finished, an ultr-sound moisture meter was use. Less than 5% moisture was detected. Basement is considered dry.

Photo 59  

Photo 60  

35)   Old water marks were noted on drywall. Not active at inspection. Continue use of a de-humidifier.

Photo 61  
 
 
Safety Concerns Return to table of contents
Ground Fault Interrupter (GFI): Not noted
GFI tested: Using testing plug, Using test button
Smoke detectors present: Yes
Smoke Detectors are located on each floor.: Yes
Carbon Monoxide Detectors: No
36) Recommend updating all smoke detectors with new.
All outlets near a water source (kitchen, bathrooms, garage, basement) should be GFI protected.
All houses, buildings and each unit in a multi-family house should have a carbon monoxide (C/O) detector. The detector should be mounted low toward the floor as carbon monoxide is heavier than air. Several C/O detectors are best. One near the heating system and hot water supply and one on each floor of the home. Again, mount C/O detectors low toward the floor.

Photo 46  
 
 

Photo 70  

Photo 72  

Photo 73  

Photo 75  

 
Thank you for using Iowa State Home Inspection's. Be sure to read the entire report and consult a qualified contractor about all concerns listed in this report. This report is not intended as a warranty of any system or structure in this report. Be sure to consult your real estate professional or your attorney about specific concerns within this report. Thank you.