Home Inspection Report

Client(s):  Jay Brandelik
Property address:  4591 Clarks Bridge Rd
Gainesville GA 30506-3363
Inspection date:  Wednesday, April 6, 2022

This report published on Wednesday, April 6, 2022 2:09:27 PM EDT

This report is the exclusive property of Georgia Pro Inspection Company, LLC and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
Concern typeSafetyPoses a risk of injury or death
Concern typeMajor DefectCorrection likely involves a significant expense
Concern typeRepair/ReplaceRecommend repairing or replacing
Concern typeRepair/MaintainRecommend repair and/or maintenance
Concern typeMinor DefectCorrection likely involves only a minor expense
Concern typeMaintainRecommend ongoing maintenance
Concern typeEvaluateRecommend evaluation by a specialist
Concern typeCommentFor your information
Concern typeDamageDamage caused by wood destroying insects or organisms (Rot, carpenter ant galleries, etc.)
Concern typeConducive conditionsConditions conducive for wood destroying insects or organisms (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.)

Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp

Table of Contents

General information
Exterior
Roof
Garage
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Fireplaces, woodstoves and chimneys
Basement
Kitchen
Bathrooms
Interior rooms

View summary

General information
Table of contents
Ryan Roberts: Ryan Roberts
Type of building: Single family
Age of building: 15 years/2007
Time started: 8:50am
Time finished: 11:20pm
Payment method: Invoiced
Present during inspection: Property owner(s), Realtor(s)
Occupied: Yes
Weather conditions: Cloudy
Temperature: Cool
Ground condition: Wet
Foundation type: Finished basement
The following items are excluded from this inspection: Private sewage disposal system, Security system, Low voltage outdoor lighting, Trampoline
1) This property has one or more fuel burning appliances, and no carbon monoxide alarms are visible. This is a safety hazard. Recommend installing one or more carbon monoxide alarms as necessary and as per the manufacturer's instructions. For more information, visit http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
2) Many wall, floor and/or ceiling surfaces were obscured by large amounts of furniture and/or stored items. Many areas couldn't be evaluated.
Photo
Photo 2-1 
Photo
Photo 2-2 
Footing material: Not visible
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Cement-based panels, Brick veneer
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Exterior door material: Solid core steel
3) One or more ground fault circuit interrupter (GFCI) electric receptacles are tripped and will not reset. This is a safety hazard due to the risk of fire and/or shock. A qualified electrician should evaluate and make repairs as necessary.

Front porch
Photo
Photo 3-1 
4) Trip hazard(s) exist at stairs due to non-uniform riser heights. Standard building practices call for riser heights not to vary more than 3/8 inch on a flight of stairs. At a minimum, the client(s) should be aware of this hazard, especially when guests who are not familiar with the stairs are present. Ideally a qualified contractor should evaluate and repair or replace stairs so all riser heights are within 3/8 inch of each other.

Front porch steps
Photo
Photo 4-1 
5) One or more deck support posts are toe-nailed to the deck structure instead of utilizing a post-to-beam connector. A qualified contractor should evaluate and make repairs as necessary.

Back deck
Photo
Photo 5-1 
Photo
Photo 5-2 
6) One or more wall-mounted exterior light fixtures have wiring that's subject to water intrusion due to caulk not being installed around the light fixture's back plate. Caulk should be applied around the perimeter of back plates where missing. A gap should be left at the bottom for condensation to drain out.
Photo
Photo 6-1 
Photo
Photo 6-2 
Photo
Photo 6-3 
7) DamageRot was found in one or more areas on fascia boards. A qualified contractor should evaluate and make repairs as necessary, replacing all rotten wood. Including but not limited to the following areas:

Front porch; column
Left side of home; top of garage door frame
Front of home; corner of porch
Photo
Photo 7-1 
Photo
Photo 7-2 
Photo
Photo 7-3 
8) Conducive conditionsSiding is damaged and/or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs and/or replace siding as necessary to prevent water and vermin intrusion. Including but not limited to the following areas:

Left side of home beside garage door
Left side of home; beside vent/s
Few places; nails exposed and backing out
Back of home
Photo
Photo 8-1 
Photo
Photo 8-2 
Photo
Photo 8-3 
Photo
Photo 8-4 
Photo
Photo 8-5 
9) Minor cracks were found in one or more sections of brick veneer. A qualified contractor should evaluate and make repairs as necessary, such as repointing mortar to prevent water intrusion and further deterioration in the future.

Front
Photo
Photo 9-1 
10) Conducive conditionsThe perimeter grading slopes towards the structure in one or more areas. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms. Wet soil may also cause the foundation to settle and possibly fail over time. Recommend grading soil so it slopes down and away from the structure with a slope of at least 5% (10% or better is optimal) for at least 6 feet.

Front beside porch; low spot at foundation
Right side of home
Photo
Photo 10-1 
Photo
Photo 10-2 
11) Conducive conditionsOne or more downspouts have no extensions, or have extensions that are ineffective. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Repairs should be made as necessary, such as installing or repositioning splash blocks, or installing and/or repairing tie-ins to underground drain lines, so rain water is carried at least several feet away from the structure to soil that slopes down and away from the structure.

Front beside porch; downspout extension not connected
Back; downspout extension damaged. Water appears to have been emptying at edge of patio
Photo
Photo 11-1 
Photo
Photo 11-2 
12) Conducive conditionsOne or more gutters are damaged. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. A qualified contractor should replace or repair gutters where necessary.

Front; dents/dings
Photo
Photo 12-1 
13) Gaps exist at one or more openings around the exterior, such as those where outside faucets, refrigerant lines, and/or gas supply pipes penetrate the exterior. Gaps should be sealed as necessary to prevent moisture intrusion and entry by vermin.
Photo
Photo 13-1 
Photo
Photo 13-2 
Photo
Photo 13-3 
Photo
Photo 13-4 
14) Conducive conditionsOne or more minor cracks (1/8 inch or less) were found in the foundation. These don't appear to be a structural concern, but recommend sealing them to prevent water infiltration and monitoring them in the future. Numerous products exist to seal such cracks including:
  • Hydraulic cement. Requires chiseling a channel in the crack to apply.
  • Resilient caulks (easy to apply).
  • Epoxy sealants (both a waterproof and structural repair).

Including but not limited to the following areas:

Right side of home
Garage floor
Basement walls
Photo
Photo 14-1 
Photo
Photo 14-2 
Photo
Photo 14-3 
Photo
Photo 14-4 
15) Conducive conditionsSoil is in contact with or less than six inches from siding and/or trim. This is a conducive condition for wood destroying insects and organisms. Soil should be graded and/or removed as necessary so there are at least six inches of space between the siding and trim and the soil below.
Photo
Photo 15-1 
Photo
Photo 15-2 
16) Conducive conditionsCaulk is missing or deteriorated in some areas and should be replaced and/or applied where necessary. For more information on caulking, visit:
The Ins and Outs of Caulking.

Few places
Photo
Photo 16-1 
Photo
Photo 16-2 
Photo
Photo 16-3 
Photo
Photo 16-4 
17) One or more sections of foundation and/or exterior walls are excluded from this inspection due to lack of access from vegetation, debris and/or stored items.
18) Minor cracks were found in the driveway. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client(s) may wish to have repairs made or have cracked sections replaced for aesthetic reasons.
Photo
Photo 18-1 
Photo
Photo 18-2 
Photo
Photo 18-3 
19) Minor cracks were found in one or more sidewalk or patio sections. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client(s) may wish to have repairs made or have cracked sections replaced for aesthetic reasons.

Front sidewalk
Back porch
Photo
Photo 19-1 
Photo
Photo 19-2 
20) The substructure of the deck is excluded from the inspection due to limited access because of the low height.

Back deck; ceiling system installed
Photo
Photo 20-1 
Roof inspection method: Viewed from ground with binoculars, Drone
Roof type: Cross gable
Roof covering: Asphalt or fiberglass composition shingles
Estimated age of roof: 2 years per SPF
Gutter & downspout material: Aluminum
Roof ventilation: Adequate
21) Conducive conditionsOne or more composition shingles have raised, most likely due to nails that have loosened. Leaks may occur as a result. A qualified roofing contractor should evaluate and make repairs as necessary, such as reseating nails.
Photo
Photo 21-1 
22) Conducive conditionsDebris such as leaves, needles, seeds, etc. have accumulated on the roof. This is a conducive condition for wood destroying insects and organisms since water may not flow easily off the roof, and may enter gaps in the roof surface. Leaks may occur as a result. Debris should be cleaned from the roof now and as necessary in the future.
Photo
Photo 22-1 
Photo
Photo 22-2 
23) The garage vehicle door is damaged or deteriorated. A qualified contractor should evaluate and repair or replace the door as necessary.

Dents/damage
Photo
Photo 23-1 
24) Much of the garage, including areas around the interior perimeter and in the center are excluded from this inspection due to lack of access from stored items.
Photo
Photo 24-1 
Photo
Photo 24-2 
Inspection method: Partially traversed
Roof structure type: Trusses
Insulation material: Fiberglass loose fill
Insulation depth: 10-12”
Insulation estimated R value: R30+
25) Some attic areas were inaccessible due to lack of permanently installed walkways, the possibility of damage to insulation, low height and/or stored items. These areas are excluded from this inspection.
Electric service
Table of contents
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service amperage (amps): 200
Service voltage (volts): 120/240
Location of main service switch: Left side of home
Location of sub panels: Basement
Main disconnect rating (amps): 200
Solid strand aluminum branch circuit wiring present: Can't verify
Smoke detectors present: Yes
26) The meter base is loose where it connects to the exterior wall. A qualified contractor should evaluate and make repairs as necessary.

Left side of home; has pulled away from exterior wall slightly at point of attachment
Photo
Photo 26-1 
27) The main service panel cover couldn't be removed due to lack of access from stored items and/or debris. This panel wasn't fully evaluated.
Photo
Photo 27-1 
28) Electrical sub-panels #1&2 (view with panel cover installed)
Photo
Photo 28-1 
Water heater
Table of contents
Estimated age: 18 years/2004; according to reference guide
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 50
Manufacturer: Bradford White
Model: DS150S6BN12
Water temperature (degrees Fahrenheit): 134 degrees
29) The hot water temperature is greater than 120 degrees Fahrenheit. This is a safety hazard due to the risk of scalding. The thermostat should be adjusted so the water temperature doesn't exceed 120 degrees. For more information on scalding dangers, visit:
http://www.cpsc.gov/cpscpub/pubs/5098.html
Photo
Photo 29-1 
30) The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be at this age or older and may need replacing at any time. Recommend budgeting for a replacement in the near future.

18 years; 2004
Photo
Photo 30-1 
Heating and cooling
Table of contents
Estimated age: 16 years/2006-both units
Primary heating system energy source: Electric
Primary heat system type: Heat pump
Primary A/C energy source: Electric
Primary Air conditioning type: Heat pump
Distribution system: Flexible ducts
Manufacturer: Carrier
Filter location: In return air duct below furnace
31) The last service date of this system appears to be more than one year ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. For safety reasons, and because this system is fueled by gas or oil, this servicing should be performed annually in the future. For more information visit:
http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
32) The estimated useful life for most heat pumps is 15 to 20 years. This heat pump appears to be approaching this age and may need replacing at any time. Recommend budgeting for a replacement in the near future.

16 years/2006-both units
Photo
Photo 32-1 
Photo
Photo 32-2 
33) The estimated useful life for air conditioning compressors is 8 to 15 years. This unit appears to have exceeded this age and may need replacing at any time. Recommend budgeting for a replacement in the near future.

16 years/2006; carrier unit
Photo
Photo 33-1 
34) Insulation for the outside condensing unit's refrigerant lines is damaged, deteriorated and/or missing in one or more areas. This may result in reduced efficiency and increased energy costs. A qualified heating and cooling contractor should replace insulation as necessary.
Photo
Photo 34-1 
35) The last service date of this system appears to be more than one year ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. This servicing should be performed annually in the future.
36) A/C Supply Temp:

Main level - 54 degrees
Upper Level - 54 degrees
Basement - 51 degrees
37) A/C Return Temp:

Main Level - 74 degrees
Upper Level - 74 degrees
Basement - 68 degrees
Plumbing and laundry
Table of contents
Location of main water shut-off valve: Basement closet with waste pump
Water service: Public
38) The clothes dryer is equipped with a vinyl or foil, accordion-type, flexible exhaust duct. The U.S. Consumer Product Safety Commission considers these types of ducts to be unsafe, and a fire hazard. These types of ducts can trap lint and are susceptible to kinks or crushing, which can greatly reduce the air flow. This duct should be replaced with a rigid or corrugated semi-rigid metal duct, and by a qualified contractor if necessary. Most clothes dryer manufacturers specify the use of a rigid or corrugated semi-rigid metal duct. For more information, visit:
http://www.cpsc.gov/CPSCPUB/PUBS/5022.html
Photo
Photo 38-1 
39) Recommend having the septic tank inspected. Recommend having the tank pumped if it was last pumped more than 3 years ago.
40) Conducive conditionsThe laundry sink is not anchored to the wall or floor. A qualified contractor should securely anchor the sink to the wall and/or floor to prevent damage to and leaks in the water supply and/or drain pipes due to the sink being moved.
Photo
Photo 40-1 
41) Neither the clothes washer nor dryer were operated or evaluated. They are excluded from this inspection.
42) The clothes washer had clothing in it and was not operated during this inspection. The inspector was unable to fully evaluate the washer and its drain line.
Photo
Photo 42-1 
Fireplaces, woodstoves and chimneys
Table of contents
Fireplace type: Metal prefabricated
Chimney type: Metal
43) The metal chimney crown is rusted. A qualified contractor should evaluate and repair, replace or paint as necessary.

Rusted
Photo
Photo 43-1 
44) A "Vent-free" gas fireplace is installed. While these are legal in some municipalities, the client(s) should be aware that exhaust gases from these appliances are vented directly into the living space where they are located. Exhaust gases may contain very high levels of moisture (up to 25%), which can be be detrimental to a house over time. Additionally, some unpleasant odors may be emitted.

Basement
Photo
Photo 44-1 
45) Chimney flue (view from below)
Photo
Photo 45-1 
Insulation material underneath floor above: Fiberglass roll or batt
46) The range can tip forward, and no anti-tip bracket appears to be installed. This is a safety hazard since the range may tip forward when weight is applied to the open door, such as when a small child climbs on it, or if heavy objects are dropped on it. Anti-tip brackets have been sold with all free standing ranges since 1985. An anti-tip bracket should be installed to eliminate this safety hazard. For more information, visit:
http://www.google.com/search?q=range+anti+tip+device

Basement
Photo
Photo 46-1 
47) The range hood fan vents into the kitchen rather than outdoors. Ventilation may be inadequate and moisture may accumulate indoors. Recommend having a qualified contractor make modifications as necessary as per standard building practices so the range hood fan vents outdoors.

Basement
Main level kitchen
Photo
Photo 47-1 
Photo
Photo 47-2 
48) One or more faucets leak by handle(s) or at their base when turned on. A qualified plumber should evaluate and repair as necessary.

Master bathroom; tub. Leak from hot water handle
Photo
Photo 48-1 
49) One or more sinks are clogged or drain slowly. Drain(s) should be cleared as necessary, and by a qualified plumber if necessary.

Upstairs bathroom
Photo
Photo 49-1 
50) Conducive conditionsCaulk is missing or deteriorated around the base of one or more bathtub spouts. It should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to wall structures.

Main level guest bathroom
Photo
Photo 50-1 
51) Conducive conditionsCaulk is missing and/or deteriorated where countertops meet backsplashes in wet areas, such as around sinks. Caulk should be replaced where deteriorated and/or applied where missing to prevent water damage.

Upstairs bathroom
Photo
Photo 51-1 
Interior rooms
Table of contents
52) Based on the age of this structure and the appearance of existing smoke alarms, the alarms may be older than 10 years old. According to National Fire Protection Association, aging smoke alarms don't operate as efficiently and often are the source for nuisance alarms. Older smoke alarms are estimated to have a 30% probability of failure within the first 10 years. Newer smoke alarms do better, but should be replaced after 10 years. Unless you know that the smoke alarms are new, replacing them when moving into a new residence is also recommended by NFPA. For more information, visit:
http://www.google.com/search?q=old+smoke+alarms
Photo
Photo 52-1 
Photo
Photo 52-2 
Photo
Photo 52-3 
53) An insufficient number of smoke alarms are installed. Additional smoke alarms should be installed as necessary so a functioning one exists in each hallway leading to bedrooms, and in each bedroom. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html

Missing in bedrooms
54) One or more interior doors have a keyed lockset or deadbolt installed. This is a safety hazard for small children in the event that they lock themselves in the room, do not know how to unlock the door, and the key is not available. Keyed locksets and/or deadbolts should be replaced as necessary with "privacy" locksets that don't require a key.

Basement
Master closet
Photo
Photo 54-1 
Photo
Photo 54-2 
55) Batteries in all the smoke alarms should be replaced after taking occupancy, and annually in the future. For more information, visit:
http://www.cpsc.gov/cpscpub/pubs/5077.html
56) Conducive conditionsStains and elevated levels of moisture were found in one or more ceiling areas. The stain(s) appear to be due to plumbing leaks. A qualified contractor should evaluate and repair as necessary.

Basement storage area; below master shower or tub area
Photo
Photo 56-1 
57) Seals between double-pane glass in one or more windows appear to have failed based on condensation or stains between the panes of glass. A qualified contractor should evaluate and replace glass where necessary.

The client(s) should be aware that evidence of broken seals may be more or less visible from one day to the next depending on the temperature, humidity, sunlight, etc. Windows or glass doors other than those that the inspector identified may also have failed seals and need glass replaced too.

Garage
Left side of home; upstairs
Main level front corner bedroom
Photo
Photo 57-1 
Photo
Photo 57-2 
Photo
Photo 57-3 
58) One or more doors will not latch when closed. Repairs should be made as necessary, and by a qualified contractor if necessary. For example, aligning strike plates with latch bolts and/or replacing locksets.

Basement bathroom
Master closet
Master bathroom
Master bedroom
Sunroom
Main level front corner bedroom
Photo
Photo 58-1 
Photo
Photo 58-2 
Photo
Photo 58-3 
Photo
Photo 58-4 
Photo
Photo 58-5 
Photo
Photo 58-6 
59) Minor cracks were found in ceilings in one or more areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons.

Nail pops; few places
Paint touch-ups visible in some areas
Photo
Photo 59-1 
Photo
Photo 59-2 

Thanks for choosing Georgia Pro Inspection Company, LLC.