Summary

Client(s):  Sample
Property address:  110 Hasbrook Drive
Bethel CT
Inspection date:  Wednesday, November 28, 2018

This report published on Friday, January 3, 2020 5:45:24 PM EST

IMPORTANT - This is not the complete inspection report but a summary. The concerns listed here are either safety issues or are, in my opinion, concerns more likely to be of a higher priority, higher cost to repair, and/or that require more immediate attention. This summary does not comprise a complete list of all defects found during the inspection. IT IS ESSENTIAL THAT YOU READ THE COMPLETE INSPECTION REPORT IN ITS ENTIRETY.

Concerns are shown and sorted according to these types:
Concern typeSafetyPoses a risk of injury or death. Have the appropriate contractor evaluate and correct the defect at once.
Concern typeRepair / ReplaceItem or component broken or not functioning as intended, or is in need of immediate attention to prevent further damage / deterioration.. Need further inspection by a specialist to determine if repair is possible or replacement is needed.
Concern typeUpgrade / Repair / ReplaceRecommend improvement, upgrading, repairing, or replacing.
Concern typeEnd of LifeSystem or component at or near end of service life. Recommend budgeting for replacement now. Monitor for any deterioration and replace as needed.
Concern typeMaintainRecommend maintenance / repair, or will need ongoing maintenance / repair.
Concern typeEvaluateRecommend evaluation by a specialist before purchasing the home. Client to assess information and determine personal level of concern. Make any repairs or replacements as suggested or needed.
Concern typeMonitorPossible defect - check this at least monthly for any change or deterioration in condition. Have appropriate contractor repair or replace as needed.
Concern typeCommentFor your information


Exterior
2) Gaps at stairs too wide (over 4"), recommend closing down or blocking. Gap should be sized so a small child cannot get through. Contact carpenter for repair.

Best practices for porch / deck stairs calls for:
* Stair risers (height of step) normally no more than 7 3/4" maximum.
* Stair risers and treads to have a maximum variation of 3/8" in height / depth.
* Stair treads (depth of stair) to have a 10" minimum tread.
* Stair risers must be closed to block passage of a 4" diameter sphere.
* Stair width normally a minimum of 36".
Have a carpenter evaluate and make any repairs as suggested.

Noted loose components and / or sway on exterior stairs, needs additional support or repair for safety.

Best practice for exterior stairs is to have a landing or platform of at least three feet square at the top and bottom. Bottoms of stairs should rest on a permanent pad (like concrete), not bear on stones, bricks, or blocks and not rest directly in the earth. Correct as needed.

Stairway should be fastened to the deck with metal hangars, none were seen here.

Boards on the deck show rot, cracks, checking, or other damage and need replacement.

Noted one or more of the deck support columns that are offset from the foundation (not sitting squarely on its support) or not fastened / supported properly. Have contractor evaluate entire deck and supports and make any needed repairs.

One or more deck or porch beams were not positively secured to the support post(s) and/or joists. Decks and porches are subject to movement under live loads and require a positive connection (not "toe-nailing" with nails) between framing members. Best practice calls for metal hangars or attachments to be tacked on for added strength.

Deck rail slightly loose, needs repair.

Deck / porch stairs should have a maximum unsupported span of six feet, with support posts under the stairs no more than six feet apart. Recommend adding posts for safety.
3) Noted cracks and deterioration of the driveway, repair or replace as needed by driveway contractor.

Looks like water is pooling here in the depressions near the garage door.
4) Noted deteriorated or rotting wood at door(s) that will need repair or replacement. Contact carpenter for evaluation and repair.

Termite contractor reports insect damage at front garage entry door that needs correction. Recommend treatment.
5) Noted deterioration to the path, patio and/or retaining wall(s) that will need repair. Contact appropriate contractor for correction.

Roof Gutters Chimneys
15) Noted exposed roofing nails, missing shingles, cracked shingles and/or holes in the roof on the roof. Recommend roofer evaluate and repair as needed.

Garage
20) The garage vehicle door(s) will not "auto-reverse", or requires too much force to reverse. The door should reverse relatively easily when closing and when it strikes something. This is a safety hazard, especially for small children. Recommend having a qualified garage door contractor evaluate and repair as necessary.

Basement or Lower Level
23) Bedroom(s) noted in basement. Recommend you add an egress window / door to the exterior for each bedroom with a minimum opening (height) of 2 feet and a minimum width opening of 20". The window / door can not be higher than 44" off the floor. Contact local Fire Marshall for further info.

Main Electrical Service
27) Ground and neutral wires and/or bus bars inside the electrical sub-panel appear to be tied together, this may be a safety issue. The neutral bus in a sub-panel is usually "floated" or isolated, not strapped to the panel enclosure or connected to the ground. Specifics of the type of sub-panel installation (# of feeder wires, location [as in a detached building], type of conduit used, whether the panels are physically connected, etc.) will have a bearing on if the grounds and neutrals should be connected. I recommend having a licensed electrician evaluate the system, make any corrections as needed.
28) One or more electrical outlets were dead at the exterior deck and at the dining room and appear to need repair. Please note that some outlets may be controlled by a switch that was not found or operated by the inspector. If the outlet was not powered off by the switch it will need to be fixed by a licensed electrician.

Deck outlet scorched, could not insert tester into outlet. Needs replacement.

Heating and Air Conditioning
38) No safety extension or a too short extension was noted on a pressure relief valve on the boiler. Need to have licensed heating contractor add for safety.
41) The estimated useful life for boilers is 15 to 20 years. This boiler appears to be approaching this age and may need replacing at any time.
42) Window / wall air conditioner(s) older, may need replacement at any time.

Bathroom 2
46) Toilet appears to be loose and may need re-anchoring. Recommend repairing so toilet is securely fastened to the floor. Loose toilets may also leak at the floor, monitor this area for any deterioration or damage and repair as needed.

Kitchen and Interior Rooms
55) While there are no markings on the smoke detector(s) to indicate age I see that they are of any older design. Normal life span for these devices is about ten years, these appear to be older. Recommend replacement for safety.

Recommend installing more carbon monoxide detectors so there is a working unit on each level of the home (none found in basement).

Make sure there are working smoke detectors in each hallway on every level of the home, and in each bedroom. Make sure there is a working carbon monoxide detector on each level of the home.
56) The ice maker, water dispenser and light for the refrigerator is not operating properly and needs repair.

The valve for the fridge water supply is located under the sink in the hall bathroom. It was shut off at the time of inspection.
57) Dishwasher needs repair to operate correctly - power was switched off and it would not fill with water. Soap door would not operate properly. Contact appliance service person for correction.

Attic
67) Water stain(s) noted in attic. Tested with moisture meter, area was damp or wet on day of inspection. Roof is leaking here (front right side). Have roofer repair flashing / roofing as needed.