This report published on Thursday, November 4, 2021 11:35:19 AM EDT
NOTICE TO THIRD PARTIES: This Report is the exclusive property of Covered Bridge Professional Home Inspections, LLC and the Client(s) listed above and is not transferable to any third parties or subsequent buyers.Our inspection and this Report have been performed with a written contract agreement that limits its scope and usefulness. Unauthorized recipients are therefore advised not to rely upon this Report, but rather to retain the services of an appropriately qualified home inspector of their choice to provide them with their own inspection and report.
Concerns are shown and sorted according to these types:
Safety
Safety concern needs to be corrected, icon is reserved for more immediate issues
Evaluate
Further review and or evaluation by a specialist prior to the end of the inspection contingency
Repair/Replace
Repair or replacement needed
Repair/Maintain
Repair or maintenance needed
Minor Defect
Correction likely minor expense or repair
Maintain
Requires on - going maintenance
Energy / Cost Savings
Energy and / or cost savings option
Monitor
Monitor now and in future
Adequate
Appears adequate / satisfactory (capable of function will show normal wear)
Comment
For your information / Inspector's recommendation
General Information
1) The purpose of a home inspection is to identify major visually observable defects that are present at the time of the inspection and to provide information regarding the condition of the home's systems and components. The inspection is non-invasive. The inspection is intended to provide information that can be used to prevent further deterioration of the property and increase the safety of the home by recommendations of the inspector. Whenever such conditions exist it is recommended that a qualified contractor be consulted for any necessary repairs.
Any recommendation made for further evaluation or repair/replace action (icons or text ) by a specialist should be investigated prior to the close of the transaction so that the client possesses a clear understanding of the magnitude of the condition, repair options, and repair costs.
The inspection is limited to readily accessible areas of the property. The inspection shall not be considered a code compliance inspection. We are generalists, not specialists holding licenses of each discipline needed to construct a home. The inspection is a snapshot in time of the home's condition on the day of inspection. The inspection and report shall not be construed to constitute a home warranty, insurance policy, or guarantee of any kind.
The inspection is supplemental to the Sellers property information (SPIR) report, where all known defects are supposed to be fully disclosed and documented by the seller.
Overview / Our Opinion
14) This was a relatively well-maintained townhouse condominium.
The most significant concerns were: balconies repairs, minor electrical, vegetation, roof shingle repair, aging hot water tank, missing sediment trap at the boiler, past plumbing leaks/ ceiling repairs.
Safety, preventive maintenance, and thermal recommendations rounded out this report.
15) Hi folks, We normally get a chance to talk with clients on-site about our inspection process, you were not able to attend, completely understandable. What I would have discussed is our reporting/inspection process is very detailed. Don't be shocked by the number of items, this is typical of our process.
Many additional photos likely have been added to give you a better "visual" experience from not being able to attend. Our overall opinion is in the "Overview " section. Please take your time to read over the report in its entirety and call or email with any questions you might have and we will follow up with you.
The electronic report is best supported verbally to ensure proper conveyance of the report findings. We are requesting the opportunity to go over the entire report (if that is what's needed) with you if, at all possible, it's very important to us and the overall process of the inspection. Please give us a call to set up a review time so we can converse and go over any questions you might have.
Exterior
18) One or more areas of balconies and or railing repairs are needed. Recommend review and repairs as needed by a qualified contractor. Please see photos.
Recommend all decks/balconies be reviewed annually for, pier movement, levelness, separation, loose railings/handrails, decay, etc. and repaired as needed by a qualified contractor. Deck safety, http://www.safestronghome.com/resources/video-hsc-deck.asp
Photo 18-1 Missing baluster noted. This is a safety concern. Photo 18-2 Balcony railings were decayed in one or more areas, recommend a qualified contractor evaluate and repair/replace as needed.
Photo 18-3 Cracked blocking at one or more balcony bolts. Recommend review/repair as necessary by a qualified contractor. Photo 18-4 Large eave design is helping to protect the deck area components below, a good design.
Photo 18-5 Photo 18-6
19) Recommend clients ask/review exterior items found in the report with the condo association. maintenance team and or owners, typically these items are managed and repaired by the condo's maintenance team. Scheduled repairs maybe already planned.
20) One or more light fixtures are loose/missing or installed in a substandard way. A qualified contractor or electrician should evaluate and make repairs as necessary so light fixtures/wiring are installed in accordance with the manufacturer's installation instructions.
Photo 20-1 Missing fixtures noted at back basement bedroom overhang. Photo 20-2 Loose low voltage equipment here as well.
21) One or more ground fault circuit interrupter (GFCI) electric receptacles are tripped and will not reset. A qualified electrician should evaluate and make repairs as necessary.
Photo 21-1 Back of the home. Minor cost/ repair.
22) Double pane windows in the home appeared to be in satisfactory condition overall.
Seals between one double-pane glass in one or more windows appear to have failed based on condensation or stains between the panes of glass. A qualified contractor should repair/replace glass where necessary.
The client(s) should be aware that evidence of broken seals may be more or less visible from one day to the next depending on the temperature, humidity, sunlight, etc. Windows or glass doors other than those that the inspector identified may also have failed seals and need glass replaced too. Please see photo.
Photo 22-1 Living room fixed window location of gas seal failure. Photo 22-2 Good quality windows and conditions elsewhere.
Photo 22-3 Photo 22-4
23) Vegetation such as trees, shrubs, and/or vines are in contact with or less than one foot from the structure's exterior. Vegetation can serve as a conduit for wood-destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one-foot clearance between it and the structure's exterior.
Trees are overhanging roofs and are within 10 feet of the roof vertically. Trees should be pruned so they are at least 10 feet above the roof, or don't overhang the roof.
Photo 23-1 Trees were in contact with roof. Photo 23-2 Shrubs were in contact with home.
Roof
33) The roof appeared to be in satisfactory condition overall with some areas needing repairs. Recommend a qualified roofer review and repair as needed.
See photos for more information.
Photo 33-1 Loose shingle sitting on the lower roof in front. Recommend repair as necessary by a qualified contractor. Photo 33-2 Repairs were noted at ridge caps. Mountain climate, roofs should be reviewed annually and repaired if needed.
41) Cover plates are cracked in one or more areas, recommend covers be replaced as needed by a qualified electrician.
Photo 41-1 Photo 41-2
42) Panel(s) appeared in satisfactory overall condition.
Some recommendations made. Please see photos.
Photo 42-1 Basement panels. Photo 42-2 Left hand panel.
Photo 42-3 One or more over-current protection devices (circuit breakers) are "double tapped", where 2 or more wires are clamped in a terminal designed for only one wire. This is a safety concern since the bolt or screw may tighten securely against one wire, but leave others loose. Very common items found during home inspections. A qualified electrician should evaluate and repair as necessary.
Photo 42-4 Recommend review of wire gauge sizes by a qualified contractor. Possible oversized wire noted at double tapped breaker.
Photo 42-5 Right hand panel. Photo 42-6 200 amp Main service disconnect at meter bank on the front of the home.
Photo 42-7 Meter at bank.
Water Heater
45) The estimated useful life for most water heaters is 8 to 15 years. This water heater appears to be at this age or older and rusty and may need replacing at any time. Recommend budgeting for a replacement in the near future.
Photo 45-1 15 year old Superstor indirect fired hot water tank. Photo 45-2 Some rust/corrosion was noted at the base and other areas of the tank.
Heating & Cooling
50) The boiler heating system was providing heat to all intended areas on the day of inspection.
No drip leg is installed on the furnace or boiler gas supply line. Drip legs are intended to trap oil, scale, water condensation and/or debris from the gas supply lines before they reach and damage the furnace or boiler components. A qualified contractor should install a drip leg as per standard building practices.
No condensate line to discharge condensate from the heating system to the drain noted. Recommend drain line and or condensate pump installation as needed by a qualified heating contractor to properly dispose of the condensate and avoid unwanted moisture. The above is the proper way to dispose of condensate.
However, condensate drains on the floor into what looks like a subsurface drain in the slab. This likely is adequate, improve with direct condensate lines to the drain as/if needed. If installing lines, it could present a trip hazard.
The last service date of this system appears to be more than one year ago, or the inspector was unable to determine the last service date. A qualified heating contractor should fully inspect, clean, service this system and all related equipment, and make repairs as /if necessary. For safety /efficiency reasons, and because this system is fueled by gas or oil, this servicing should be performed annually in the future.https://www.energystar.gov/index.cfm?c=heat_cool.pr_maintenance
Additional thermostatic sensoring was installed/noted by owner. Likely through the security system. Recommend asking owner about the nature of the sensors and best practices/operation.
Photo 50-1 Photo 50-2
Photo 50-3 6 year old NTI high efficiency gas boiler. Photo 50-4
Photo 50-5 No visible drip leg noted at gas supply line to the boiler.
51) The outdoor air temperature was below 65 degrees Fahrenheit during the inspection. Because of this, the inspector was unable to operate and fully evaluate the cooling system. This is the industry standard used as not to damage the equipment. Consult owners and or a cooling contractor about the AC systems operation prior to the end of the inspection contingency to ensure operation.
Recommend maintenance per manufacturer's instructions.
Insulation for the outside condensing unit's refrigerant lines is damaged, deteriorated, and/or missing in one or more areas. This may result in reduced efficiency and increased energy costs. A qualified heating and cooling contractor should replace insulation as necessary.
Recommend cover / and or protection for outside AC units in winter months. Preventive maintenance.
Photo 51-1 Interior air handlers. Installed three years ago per owner. Photo 51-2 Outdoor condensers Age:2012/2020
Photo 51-3 Insulation at refrigerant lines was deteriorated.
Bathrooms
73) The water stopper mechanism is not sealing, missing, or needs adjustment or repair to hold water. Stopper mechanisms should be installed where missing and/or repairs should be made so stoppers function properly.
Photo 73-1 Lower floor non jetted tubs. Photo 73-2
Interior Rooms
78) One or more light fixtures appear to be inoperable. Recommend further evaluation by replacement of bulb(s). Repairs or replacement of the light fixture(s) by a qualified electrician may be necessary.
Photo 78-1 Great room Photo 78-2 Basement hall.
79) The ceiling has been repaired in one or more areas. Past plumbing leaks were noted by the owner. Likely the reason behind ceiling work in lower floors. Some areas require finish coat of paint. Recommend paint by a qualified contractor.
Photo 79-1 Ceiling disturbed/repaired in basement. Photo 79-2
Photo 79-3 Some ceiling areas require topcoat of paint.