Bathrooms, Laundry and Sinks
30) 

The clothes dryer exhaust duct was kinked, crushed or damaged. Air flow will be restricted as a result and the clothes dryer may overheat. This is a safety hazard due to the risk of fire. Recommend that a qualified person replace or repair the duct as necessary. For more information, visit:
http://www.cpsc.gov/CPSCPUB/PUBS/5022.pdf
31) 

The clothes dryer exhaust duct appeared to need cleaning. Significant amounts of lint build-up were visible and may reduce air flow. This is a fire hazard. Recommend that a qualified person clean this duct now and as necessary in the future. Some chimney sweeps or heating/cooling duct cleaners perform this service. For more information, visit:
http://www.cpsc.gov/CPSCPUB/PUBS/5022.pdf
32) 

Vinyl flooring in the bathroom was damaged, deteriorated. Water can damage the the subfloor as a result. Recommend that a qualified contractor replace or repair flooring as necessary.
33) 

The bathroom with a shower or bathtub didn't have an exhaust fan installed. Moisture can accumulate and result in mold, bacteria or fungal growth. Even if the bathroom has a window that opens, it may not provide adequate ventilation, especially during cold weather when windows are closed or when wind blows air into the bathroom. Recommend that a qualified contractor install exhaust fans per standard building practices where missing in bathrooms with showers or bathtubs.
34) 
One or more cabinets, drawers and/or cabinet doors at location(s) #A, B were damaged or deteriorated. Recommend that a qualified person repair or replace as necessary.
35) 

One or more sink drains were leaking at location(s) #A. A qualified person should repair as necessary.
36) 

Gaps, no caulk, or substandard caulking were found between the bathtub and the floor, walls. Water may penetrate these areas and cause damage. Recommend that a qualified person re-caulk or install caulking as necessary.
37) 

Tile and/or grout in the bathtub was deteriorated (e.g. loose or cracked tiles, missing grout) or substandard. Water can damage the wall structure as a result. Recommend that a qualified contractor repair as necessary.
38) 
Water was leaking at the sink faucet base or handles at location(s) #A. Recommend that a qualified plumber repair as necessary.
39) 
The sink drain stopper mechanism at location(s) #A, B was loose. Recommend that a qualified person repair or replace as necessary.
40) 
The toilet fill valve or float mechanism in the toilet at location(s) #A did not operate properly or was inoperable. Recommend that a qualified person repair as necessary.
41) 
Rubber water supply hoses were installed at the clothes washer. These hoses are prone to bursting when deteriorated, which can result in flooding and significant water damage. Recommend upgrading to braided, stainless steel hoses.
Interior, Doors and Windows
42) 

Water stains or evidence of leaking was found at one or more windows. Recommend that a qualified contractor evaluate and repair as necessary.
43) 
One or more window screens were damaged or deteriorated. These window(s) may not provide ventilation during months when insects are active. Recommend replacing window screens as necessary.
44) 
One or more interior doors were missing. Recommend that a qualified person replace or repair doors as necessary.
45) 
The lock mechanisms on the sliding scree door was inoperable. Recommend that a qualified person repair as necessary.
46) 
Trim was missing in one or more areas. Recommend that a qualified person repair as necessary.
47) 
Weatherstripping at one or more exterior doors was deteriorated . Water may enter the building, or energy efficiency may be reduced. Recommend that a qualified person repair or replace weatherstripping as necessary.
48) 
Minor cracks, nail pops and/or blemishes were found in walls and/or ceilings in one or more areas. Cracks and nail pops are common, are often caused by lumber shrinkage or minor settlement, and can be more or less noticeable depending on changes in humidity. They did not appear to be a structural concern, but the client may wish to repair these for aesthetic reasons. For recurring cracks, consider using an elastic crack covering product:
http://www.google.com/search?q=elastic+crack+cover