Summary
Unofficial version!

Client(s): The Savvy Buyers
Property address: 9876 New Construction Way

Coeur D'Alene Id 83814
Inspection date: Wednesday, July 26, 2023

This report published on Friday, March 8, 2024 10:37:05 AM PST

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

Concerns are shown and sorted according to these types:
Concern typeSafetyPoses a safety hazard
Concern typeRepair RecommendedItem was not functioning as designed or intended. Correction should be performed, and may require a professional, specialist, or other knowledgeable person.
Concern typeMaintenance ReminderRecommend routine attention and maintenance to keep item in proper working condition.
Concern typeInvestigate FurtherRecommend additional investigation, research, or review by a specialist and/or client
Concern typeInformational CommentReport comment included for your information and consideration.

General Information
1)  To view the summary. Click on the link in the upper left hand corner or under table contents.
Exterior and Foundation
4)  The paint or stain finish in some areas was failing (e.g. peeling, faded, worn, thinning). Siding and trim with a failing finish can be damaged by moisture. Recommend that a qualified contractor prep (e.g. clean, scrape, sand, prime, caulk) and repaint or restain the building exterior where necessary and per standard building practices. Any repairs needed to the siding or trim should be made prior to this.
Photo
Photo 4-1 
Photo
Photo 4-2 
Photo
Photo 4-3 
Photo
Photo 4-4 
5)  Exhaust duct end caps were painted shut and didn't fully open. Blocked ducts can cause fan motors to overheat. Recommend that a qualified person repair exhaust caps. For example, cut paint from louvres.

One crawlspace vent well was dented. Air flow was not impeded at time of inspection.
Photo
Photo 5-1 
Photo
Photo 5-2 
Crawl Space
7)  Microbial staining was visible on floor sheathing in the crawlspace. Such staining usually occurs due to elevated humidity in the crawlspace during construction, and subsequent elevated moisture levels in the sheathing. When humid crawlspace conditions have been corrected, it's likely that such staining will stop growing. Mold abatement specialists can remediate current microbial staining which typically involves the following:
  • Clean microbial staining from wood surfaces
  • Treat wood surfaces with mildewcides
  • Prime wood with special primers
Note that the inspector is not a mold specialist or industrial hygienist and provides no professional opinion on health issues related to microbial growth.
Photo
Photo 7-1 
Photo
Photo 7-2 
Photo
Photo 7-3 
Photo
Photo 7-4 
Photo
Photo 7-5 
Photo
Photo 7-6 
8)  Under-floor insulation was falling down in one area. This may result in reduced energy efficiency. Recommend that a qualified person repair or replace insulation as necessary
Photo
Photo 8-1 
Roof
10)  Gaps were found in or around roof soffits and can allow birds or vermin to enter the attic. Recommend that a qualified person repair as necessary to eliminate gaps.
Photo
Photo 10-1 
Photo
Photo 10-2 
Photo
Photo 10-3 
Photo
Photo 10-4 
11)  The rain cap for the garage heating b-vent needs to be sealed. Leaks can occur. Recommend that a qualified person repair as needed.
Photo
Photo 11-1 
Attic and Roof Structure
13)  Attic access hatch was missing. Recommend a qualified person install insulated hatch cover..
Photo
Photo 13-1 
Photo
Photo 13-2 
14)  Some framing at hip appeared substandard when compared to best building practices at hip at approximate center of house. For example, rafter ends not flush cut, truss/rafter extensions not support for hip roof. Recommend confirming with builder that this is to engineered specs.
Photo
Photo 14-1 
Photo
Photo 14-2 
Photo
Photo 14-3 
Photo
Photo 14-4 
Photo
Photo 14-5 
Photo
Photo 14-6 
Electric
17)  Light was missing at the front garage soffit. Recommend a qualified person install light.
Photo
Photo 17-1 
18)  Knockout was missing at exterior panel. Rodents can enter panels through holes. Recommend that a qualified person install knockout covers where missing and per standard building practices.
Photo
Photo 18-1 
19)  Light fixtures were inoperable (didn't turn on when nearby switches were operated). Sensors were present which may prevent lights from turning on when light outside.

Recommend further evaluation by checking with builder about switches and/or sensors.
Photo
Photo 19-1 
Photo
Photo 19-2 
Photo
Photo 19-3 
Photo
Photo 19-4 
Plumbing / Fuel Systems
23)  Leaks were found in drain pipes or fittings under spare bathroom tub. A qualified plumber should evaluate and repair as necessary.
Photo
Photo 23-1 
Photo
Photo 23-2 
24)  Based on visible equipment, this property appeared to have a yard irrigation (sprinkler) system. These are specialty systems and are not a part of a typical home inspection. A recent backflow test tag was not visible. Backflow tests are required annually in many municipalities in our area to prevent cross-contamination of potable water. Recommend asking current owners about test and obtaining work orders if available. If no test has been performed, recommend a qualified specialist perform a backflow test.
Photo
Photo 24-1 
Photo
Photo 24-2 
Water Heater
28)  Digital display was inoperable at time of inspection. Builder stated part was coming to repair.

The hot water temperature was greater than 120 degrees Fahrenheit. This is a safety hazard due to the risk of scalding. The thermostat should be adjusted so the water temperature doesn't exceed 120 degrees

A tankless water heater was observed at this property. It is beyond the scope of this inspection to determine the adequacy of this system since demand varies significantly with water usage. For example, with simultaneous showers while washing clothes or dishes, etc. During such usage, tankless water heaters may not keep up with demand. This inspection includes a limited evaluation of the water heater to determine the following:
  • Does it supply hot water?
  • Is the water pressure adequate for the unit (typically minimum 30-50 psi)?
  • Is combustion air and the venting system serviceable?
  • Is the wiring for the electric supply safe?
  • Is a temperature-pressure relief valve and drain line installed?
Any concerns observed related to the above items are noted in this report.

NAVIAN 240A Cleaning instructions. https://www.youtube.com/watch?v=yBkTk3bTmnY
Photo
Photo 28-1 
Photo
Photo 28-2 
Photo
Photo 28-3 
Photo
Photo 28-4 
Heating, Ventilation & A/C If Applicable (HVAC)
29)  No serviceman's switch was visible for the furnace. This is a switch that allows power to be turned off quickly if something goes wrong when someone is performing maintenance or repairs. This is a potential safety hazard. Requirements vary by municipality, but general guidelines require the switch be within an arm's length of the appliance. In some cases the disconnect at the electric panel (e.g. circuit breaker or fuse) may suffice if it's within sight of the appliance. Recommend that a qualified contractor install a serviceman's switch per standard building practices.
Photo
Photo 29-1 
Photo
Photo 29-2 
30)  The air handler's primary condensate drain line was leaking in attic. Condensate drain water may accumulate, leak and cause water damage to surrounding areas. Recommend that a qualified HVAC contractor repair as necessary.
Photo
Photo 30-1 
Photo
Photo 30-2 
31)  Work space platform in attic appeared to be inadequate. Minimum 30 inches for depth and width in front of appliance is recommended. Recommend a qualified specialist evaluate and repair as necessary.
Photo
Photo 31-1 
32)  The catch pan for the high-efficiency furnace and air conditioning equipment in attic was filled with insulation. These systems produce condensation which is normally eliminated via a primary drain line. However, condensate water can leak if the primary drain line clogs. A catch pan is installed below the air handler, with a float switch that will turn off the system if water accumulates in the catch pan. Insulation can affect this function and should be cleared from pan and float switch.
Photo
Photo 32-1 
Photo
Photo 32-2 
Photo
Photo 32-3 
Photo
Photo 32-4 
33)  Drywall dust, and construction debris such as drywall dust and/or sawdust was found behind or below heating or cooling air supply registers. Drywall dust in particular can reduce the life of heating and cooling equipment if left to circulate. At a minimum, recommend vacuuming ducts at each register. Consider having a qualified contractor clean the ducts.

Register in bonus area closet was ill fitting.

Only one register was present in bonus living area. One was located in bathroom and one in closet. It is beyond the scope of a home inspection to determine if this is adequate for the space.
Photo
Photo 33-1 
Photo
Photo 33-2 
Photo
Photo 33-3 
Photo
Photo 33-4 
34)  Furnace and A/C was functioning at time of inspection.

Unit is new, recommend annual servicing in the future for warranty purposes.

The filter should be changed upon move in. How often a filter should be changed depends on environmental factors (ie pets, smoking, dust, etc) but a general rule of thumb is every 3 months. Adjust time according to observation.
Photo
Photo 34-1 
Photo
Photo 34-2 
Photo
Photo 34-3 
Photo
Photo 34-4 
Photo
Photo 34-5 
Photo
Photo 34-6 
Fireplaces, Stoves, Chimneys and Flues
35)  Gas fireplace was functional at time of inspection.

Lights within fireplace did not turn on.

The blower for the gas-fired fireplace or stove did not operate. The inspector did not determine why. This can be due to various reasons such as a switch that wasn't found, or a thermostat not reaching a high enough temperature. Consult with the property owner and review documentation for such appliances. If necessary, a qualified specialist should evaluate and repair.

Batteries were present at emergency electric start. Battery receiver is typically for emergency use only when power is out and fireplace needs to be operated. Batteries should not be stored in receiver due to risk of corrosion and damage to receiver.

Recommend that the client review all available documentation for gas-fired fireplaces and stoves. Depending on how they are operated (for routine heating versus ambiance), such appliances may need servicing annually or every few years.
Photo
Photo 35-1 
Photo
Photo 35-2 
Photo
Photo 35-3 
Photo
Photo 35-4 
Kitchen
36)  The under-sink food disposal was inoperable as it was not completely installed. Recommend that a qualified contractor repair or replace as necessary.
Photo
Photo 36-1 
Photo
Photo 36-2 
37)  Handle was not installed on microwave.
Photo
Photo 37-1 
Photo
Photo 37-2 
38)  No dishwasher toe kick was installed and no leaks were observed at time of inspection.

Inspector performs a limited function test of appliances and runs dishwasher for short cycle. Deficiencies at time of inspection are noted above if
Photo
Photo 38-1 
Photo
Photo 38-2 
Photo
Photo 38-3 
Photo
Photo 38-4 
Photo
Photo 38-5 
Photo
Photo 38-6 
Photo
Photo 38-7 
Photo
Photo 38-8 
Bathrooms, Laundry and Sinks
39)  Inspector could not get far third shower head and shower head on master bathtub to function in master bathroom. Recommend asking builder about function and repair if necessary.
Photo
Photo 39-1 
Photo
Photo 39-2 
Photo
Photo 39-3 
Photo
Photo 39-4 
40)  The hot and cold water supplies appeared to be reversed at the bathtub at location(s) #B according to markings on handle. Normally, cold water is controlled by the right faucet handle and hot by the left. For mixing faucets, cold is supplied with the handle to the right and hot when the handle is to the left, or as indicated by the faucet's markings. At a minimum this is an inconvenience, but it can also result in accidental scalding. Recommend that a qualified plumber repair as necessary.
Photo
Photo 40-1 
41)  The hot water supply flow for the laundry sink was inoperable. Recommend that a qualified plumber evaluate and repair as necessary.

Supply was off when inspector arrived. Inspector turned them on briefly to test.
Photo
Photo 41-1 
Photo
Photo 41-2 
42)  We recommend when first running the dryer to confirm that it is blowing to exterior by observing exterior louvres.
Photo
Photo 42-1 
Interior, Doors and Windows
44)  Trim piece was missing from rear door.

Strike plate was missing at garage exterior door.
Photo
Photo 44-1 
Photo
Photo 44-2