This report published on Sunday, September 10, 2023 8:32:41 AM PDT
Please understand that there are limitations to this inspection. Many components of the home are not visible during the inspection and very little historical information is provided in advance of the inspection. While we can reduce your risk of purchasing a home, we cannot eliminate it, nor can we assume it. Even the most comprehensive inspection cannot be expected to reveal every condition you may consider significant to ownership.
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
Safety
Poses a safety hazard
Major Defect
Correction likely involves a significant expense
Repair Recommended
Item was not functioning as designed or intended. Correction should be performed, and may require a professional, specialist, or other knowledgeable person.
Maintenance Reminder
Recommend routine attention and maintenance to keep item in proper working condition.
Investigate Further
Recommend additional investigation, research, or review by a specialist and/or client
Informational Comment
Report comment included for your information and consideration.
Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp
Client present for discussion at end of inspection: Yes
Inspector: Timber and Patrick
Weather conditions during inspection: Dry (no rain), Sunny
Temperature during inspection: Hot
Sq. footage.: 3802
Age of main building: 1991(32 years)
Source for main building age: Municipal records or property listing
Occupied: No, Furniture or stored items were present
1) To view the summary. Click on the link in the upper left hand corner or under table contents.
2) Evidence of rodent and ant activity was found in the form of sawdust, dead ants, feces, traps and/or poison in the interior rooms, crawlspace and around front window. Consult with the property owner about this. A qualified person should evaluate ant damage and make repairs to seal openings in the structure, set traps, spray, and clean rodent waste as necessary. Recommend following guidelines in these Center for Disease Control articles: http://www.reporthost.com/?SEALUP http://www.reporthost.com/?TRAPUP http://www.reporthost.com/?CLEANUP
Photo 2-1 Photo 2-2
Photo 2-3 Photo 2-4
Photo 2-5 Photo 2-6
Photo 2-7 Photo 2-8
Photo 2-9 Photo 2-10
3) Microbial growths were found in basement under stairs. It is beyond the scope of this inspection to identify what substance or organism this staining is. However such staining is normally caused by excessively moist conditions, which in turn can be caused by plumbing or building envelope leaks and/or substandard ventilation. These conducive conditions should be corrected before making any attempts to remove or correct the staining. Normally affected materials such as drywall are removed, enclosed affected spaces are allowed to dry thoroughly, a mildewcide may be applied, and only then is drywall reinstalled. For evaluation and possible mitigation, consult with a qualified industrial hygienist or mold/moisture mitigation specialist. For more information, visit: http://www.reporthost.com/?MOLDCDC http://www.reporthost.com/?MOLDEPA
Dry at time of inspection.
Photo 3-1 Photo 3-2
Photo 3-3 Photo 3-4
Photo 3-5 Photo 3-6
4) Some areas and items at this property were obscured by furniture and stored items. This often includes but is not limited to walls, floors, windows, inside and under cabinets, under sinks, on counter tops, in closets, behind window coverings, under rugs or carpets, and under or behind furniture. Areas around the exterior, under the structure, in the garage and in the attic may also be obscured by stored items. The inspector in general does not move personal belongings, furnishings, carpets or appliances. When furnishings, stored items or debris are present, all areas or items that are obscured, concealed or not readily accessible are excluded from the inspection. The client should be aware that when furnishings, stored items or debris are eventually moved, damage or problems that were not noted during the inspection may be found.
Limitations: Unless specifically included in the inspection, the following items and any related equipment, controls, electric systems and/or plumbing systems are excluded from this inspection: detached buildings or structures; fences and gates; retaining walls; underground drainage systems, catch basins or concealed sump pumps; swimming pools and related safety equipment, spas, hot tubs or saunas; whether deck, balcony and/or stair membranes are watertight; trees, landscaping, properties of soil, soil stability, erosion and erosion control; ponds, water features, irrigation or yard sprinkler systems; sport courts, playground, recreation or leisure equipment; areas below the exterior structures with less than 3 feet of vertical clearance; invisible fencing; sea walls, docks and boathouses; retractable awnings. Any comments made regarding these items are as a courtesy only.
Retaining wall material: Concrete, Rock
Site profile: Moderate slope
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete, Paving stones
Deck, patio, porch cover material and type: Covered (Refer to Roof section), Open
Deck, porch and/or balcony material: Wood
Exterior stair material: Wood
5) Fungal rot was found in support posts, some beams and decking boards and planters at deck. Recommend that a qualified tradesman evaluate and repair as necessary. All rotten wood should be replaced.
Guardrails with drop-offs higher than 30 inches were wobbly, and pose a fall hazard. Recommend that a qualified person repair guardrails as necessary.
Some of the substructure could not be evaluated due to limited height.
Photo 5-1 Photo 5-2
Photo 5-3 Photo 5-4
Photo 5-5 Photo 5-6
Photo 5-7 Photo 5-8
Photo 5-9 Photo 5-10
Photo 5-11 Photo 5-12
Photo 5-13 Photo 5-14
Photo 5-15 Photo 5-16
Photo 5-17 Photo 5-18
Photo 5-19 Photo 5-20
6) Guardrails at locations with drop-offs higher than 30 inches were too low. This poses a fall hazard. Guardrails should be at least 36 inches in height. Recommend that a qualified contractor replace or repair guardrails per standard building practices.
Photo 6-1
7) This property was accessed by a driveway or private road shared with nearby properties. Shared driveways or private roads are excluded from this inspection. Comments in this report related to them are made as a courtesy only and are not meant to be a substitute for a evaluation by a specialist if repairs are needed. Recommend that the client review the recorded agreements regarding the driveway, the deeds of the property owners involved, and easements permitting access to, use of, and maintenance of the driveway.
8) The soil or grading sloped down towards building perimeters. This can result in water accumulating around building foundations or underneath buildings. At a minimum, monitor these areas, and areas under the structure in the future for accumulated water. If water does accumulate, recommend grading soil so it slopes down and away from buildings with a slope of at least 1 inch per horizontal foot for at least 6 feet out from buildings.
Limitations: The inspector performs a visual inspection of accessible components or systems at the exterior. Items excluded from this inspection include below-grade foundation walls and footings; foundations, exterior surfaces or components obscured by vegetation, stored items or debris; wall structures obscured by coverings such as siding or trim. This may limit a full evaluation. Regarding foundations, some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determine the adequacy of seismic reinforcement.
Wall inspection method: Viewed from ground
Apparent wall structure: Wood frame
Wall covering: Wood, Stone or faux stone veneer
Apparent foundation type: Finished basement
Foundation/stem wall material: Poured in place concrete
9) Trees were in contact with or were close to the building at locations. Damage to the building may occur, especially during high winds. Recommend that a qualified tree service contractor or certified arborist remove trees as necessary to prevent damage to the building exterior.
Photo 9-1 Photo 9-2
10) Rot was observed at butt end at front of house and three posts. Recommend a qualified contractor evaluate and repair.
Companies such as Mountain Country Log at (208) 783-8112 provide these services.
The finish on the log exterior was worn, faded or thinning, or mold/mildew was present on logs. The logs can be damaged by moisture. This is a conducive condition for rot. Recommend that a qualified person prep and refinish the log exterior. Logs should first be cleaned of dirt, grease, mold and mildew with an appropriate cleaner and pressure washer. It is good practice to then apply a preservative (typically borate-based) to prevent rot and insect infestation, before applying the final finish. Ideally the same brand of finish should be applied to minimize problems from incompatible finish products. For more information, visit: http://www.reporthost.com/?LOGFNSH http://www.reporthost.com/?LOGMT
Gaps between logs, deteriorated chinking, and/or excessive checking (gaps within logs) was found in areas. Some log homes use milled logs that fit tightly together and are designed so as to not require chinking ("chinkless"). Others do require chinking and possibly "backer rods" between logs for a tight seal. Regardless of the type, when gaps are present repairs should be made to prevent air, moisture and insect infiltration from outside. Typically this is done by applying chinking, which can be synthetic or mortar-based. Recommend that a qualified person apply chinking where necessary. For more information, visit: http://www.reporthost.com/?LOGCHNK
Photo 10-1 Photo 10-2
Photo 10-3 Photo 10-4
Photo 10-5 Photo 10-6
Photo 10-7 Photo 10-8
Photo 10-9 Photo 10-10
11) The "rowlock" above sections of stone veneer was missing coping flashing. Coping flashing should be installed below the sills and overlapping the top course of stones in the veneer to keep water from entering the wall cavity. In lieu of flashing, client should consider sealing seam with silicone to minimize moisture intrusion.
Limitations: Structural components such as joists and beams, and other components such as piping, wiring and/or ducting that are obscured by under-floor insulation are excluded from this inspection. The inspector does not guarantee or warrant that water will not accumulate in the crawl spaces in the future. Complete access to all crawl space areas during all seasons and during prolonged periods of all types of weather conditions (e.g. heavy rain, melting snow) would be needed to do so. Note that crawl space areas should be checked at least annually for water intrusion, plumbing leaks and pest activity.
Crawl space inspection method: Traversed
Location of crawl space access point #A: Basement
Crawl space access points that were opened and viewed, traversed or partially traversed: A
Sub-floor material: Plywood
Pier or support post material: Wood
Beam material: Built-up wood
Floor structure above: Solid wood joists
Insulation material underneath floor above: Fiberglass roll or batt
Vapor barrier present: Yes
Ventilation type: with vents
12) The vapor barrier in one small area of the crawl space was missing and substandard in all areas. Vapor barrier was clear. Soil was exposed as a result and will allow water from the soil to evaporate up into the structure. A 6 mil black plastic sheet should be placed over all exposed soil with seams overlapped to 24 inches, and not in contact with any wood structural components. The sheeting should be held in place with bricks or stones, not wood. Recommend that a qualified person replace or repair the vapor barrier where necessary and per standard building practices.
Photo 12-1 Photo 12-2
13) The crawl space was dry at time of inspection. Crawl space insulation and duct work satisfactory. Note that all crawlspace areas should be checked periodically for water intrusion, plumbing leaks and pest activity.
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; Any comments made regarding these items are made as a courtesy only. Note that the inspector does not provide an estimate of remaining life on the roof surface material, nor guarantee that leaks have not occurred in the roof surface, skylights or roof penetrations in the past. Regarding roof leaks, only active leaks, visible evidence of possible sources of leaks, and evidence of past leaks observed during the inspection are reported on as part of this inspection. The inspector does not guarantee or warrant that leaks will not occur in the future. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high wind and rain, melting snow) would be needed to do so. Occupants should monitor the condition of roofing materials in the future.
Roof inspection method: Traversed
Roof surface material: Architectural shingles
Roof type: Gable, Hipped
Apparent number of layers of roof surface material: One
Gutter and downspout installation: None
14) Composition shingles were installed on a slope with less than 3/12 (3 inches rise for every 12 inches run). Such low-slope shingle installations are prone to leaks due to the slow rate at which water runs off the shingles. Roof decking can also be prone to sagging, and the roof structure may have a reduced load capacity for snow. Most shingle manufacturers won't warranty shingles if installed on a roof with a slope less than 3/12. Consult with a qualified contractor regarding this and monitor these roof area(s) and interior spaces below for leaks in the future. Ideally, or if leaks occur, recommend that a qualified contractor repair per standard building practices. Such repairs may involve installing a new roof surface approved for low slopes.
Photo 14-1 Photo 14-2
15) Vegetation such as trees, shrubs, and/or vines overhung the roof surface or were in contact with the roof edge. Organic debris such as leaves or needles are likely to accumulate in gutters and on the roof surface. Gutters can overflow and cause water to come in contact with the building exterior or water can accumulate around the foundation. Vegetation in contact with the roof can damage the roof surface and/or the roof drainage system. Recommend pruning vegetation so as to not be in contact with the roof and to not overhang the roof surface. If vegetation is too tall then it should be pruned at least 10 feet above the roof surface.
Photo 15-1 Photo 15-2
16) Kick-out flashing was missing at roof locations. Such flashing should be located at the bottom of slopes where roof surfaces intersect with exterior walls above. It directs rainwater away from exterior walls and into gutters so that rainwater is less likely to run down the front surfaces of siding or flow behind siding. Recommend that a qualified contractor install kickout flashings where missing and per standard building practices.
Photo 16-1 Photo 16-2
Photo 16-3 Photo 16-4
17) The siding at exterior walls was in contact with or too close to roof surfaces below. There should be a gap of 1 1/2 to 2 inches between a roof surface and siding above. The gap is meant to prevent water from wicking up into the bottom edge of the siding and causing fugal rot, or damaging the siding. There may also be inadequate space for additional layers of roofing materials in the future. Recommend that a qualified contractor repair per standard building practices. For example, by trimming the siding.
Photo 17-1
18) Architectural roofing has an average life expectancy between 25 to 35 years depending on the weather conditions and attic ventilation.
No gutter system was installed. Standard building practices call for gutters, downspouts and extensions to be installed at all lower roof edges to convey water well away from the building foundation. Without a drainage system, the crawlspace or basement below the house, may accumulate water. Foundation footings are also more likely to settle or become undermined. Recommend consulting with a qualified contractor about installing a roof drainage system per standard building practices.
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation. Any comments made regarding these items are made as a courtesy only. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high/low temperatures, high/low humidity, high wind and rain, melting snow) would be needed to do so.
Attic inspection method: Partially traversed
Location of attic access point #A: Hallway, second floor
Attic access points that were opened and viewed, traversed or partially traversed: A
19) The slot at the roof ridge for the continuous ridge venting blocked by underlayment. Most manufacturers of this type of venting system require a slot 1 1/2 inches wide or wider. Recommend that a qualified contractor repair per the manufacturer's specifications.
Photo 19-1 Photo 19-2
Photo 19-3 Photo 19-4
20) What appeared to be past water stains were visible on the roof structure at the chimney in the attic. However, no elevated levels of moisture were found at these stains during the inspection. The stains may have been caused by a past leak. Recommend asking the property owner about past leaks. Monitor these areas in the future, especially after heavy rains to determine if active leaks exist. If leaks are found, recommend that a qualified contractor evaluate and repair as necessary.
Photo 20-1
21) Attic insulation and venting.
All attic areas and roof structures more than 12 feet from attic access point(s) #A were inaccessible due to possible damage to insulation if traversed, lack of permanent walkways and/or limited height. These areas were not evaluated and are excluded from the inspection.
Limitations: The inspector does not determine the adequacy of firewall ratings. Requirements for ventilation in garages vary between municipalities.
Type: Detached
Type of garage vehicle door: Sectional
Number of vehicle doors: 3
Condition of automatic opener(s): Satisfactory
Mechanical auto-reverse operable (reverses when meeting reasonable resistance during closing): Yes
Condition of detached garage or carport structure: Satisfactory
Apparent wall structure: Wood frame
Roof inspection method: Traversed
Roof type: Gable
Roof surface material: Architectural shingles
22) No photoelectric sensors were installed at the garage vehicle doors' automatic opener. These have been required on all automatic door openers since 1993 and improve safety by triggering the door's auto-reverse feature without need for the door to come in contact with the object, person or animal that is preventing the door from closing. These are difficult to install on older automatic opener. For more information on garage door safety issues, visit: http://www.reporthost.com/?GDPES
Photo 22-1 Photo 22-2
Photo 22-3 Photo 22-4
23) Water supply pipes were routed in an area subject to freezing in the garage. Recommend asking the property owner about any indoor shut-off valves that may exist for these supply pipes . If unable to determine or if none do, then recommend that a qualified plumber evaluate and repair as necessary. For example, by installing indoor shut-off valves or rerouting supply pipes indoors.
Photo 23-1 Photo 23-2
Photo 23-3 Photo 23-4
24) The house does not meet current standards.
Current safety standards recommend smoke alarms should be installed in each bedroom, in hallways leading to bedrooms, and on each level. They have a limited lifespan and should be replaced every 10 years. Batteries in smoke alarms should be changed when taking occupancy and annually in the future. Carbon monoxide alarms should be installed near sleeping areas and on each level in homes with a fuel-burning appliance or attached garage. For more information, visit: http://www.reporthost.com/?SMKALRM http://www.reporthost.com/?COALRM
Photo 24-1
25) Gaps, no caulk, or substandard caulking were found at backsplash at kitchen sink. Water may penetrate these areas and cause damage. Recommend that a qualified person repair as necessary. For example, by installing caulk.
Photo 25-1
26) The dishwasher did not respond to controls. Recommend that a qualified specialist evaluate and repair or replace as necessary.
Photo 26-1 Photo 26-2
27) Minor moisture damage at flooring was observe in kitchen area but no moisture was detected at time of inspection.
Photo 27-1 Photo 27-2
28) Garage vehicle door was balanced at time of inspection.
30) Inspector performs a limited function test of appliances and runs dishwasher for short cycle. Deficiencies at time of inspection are noted above if present.
Inspector ran water in the sink(s) and bathtub(s). Ran shower water and flushed toilet(s). No leaks were noted at time of inspection.
Photo 30-1 Photo 30-2
Photo 30-3 Photo 30-4
Photo 30-5 Photo 30-6
Photo 30-7 Photo 30-8
Photo 30-9 Photo 30-10
31) Attic spaces less than 30 inches in height may exist in this building, but had no visible access points. This is acceptable per standard building practices. However, these spaces were not inspected and are excluded from this inspection.
Limitations: The inspector does not operate circuit breakers as part of the inspection, and does not install or change light bulbs. The inspector does not evaluate every wall switch or receptacle, but instead tests a representative number of them per various standards of practice. When furnishings, stored items or child-protective caps are present some receptacles are usually inaccessible and are not tested; these are excluded from this inspection. Receptacles that are not of standard 110 volt configuration, including 240-volt dryer receptacles, are not tested and are excluded. The functionality of, power source for and placement of smoke and carbon monoxide alarms is not determined as part of this inspection. Upon taking occupancy, proper operating and placement of smoke and carbon monoxide alarms should be verified and batteries should be changed. These devices have a limited lifespan and should be replaced every 10 years. The inspector attempts to locate and evaluate all main and sub-panels. However, panels are often concealed. If panels are found after the inspection, a qualified electrician should evaluate and repair if necessary. The inspector attempts to determine the overall electrical service size, but such estimates are not guaranteed because the overall capacity may be diminished by lesser-rated components in the system. Any repairs recommended should be made by a licensed electrician.
Primary service type: Underground
Number of service conductors: 3
Service voltage (volts): 120-240
Estimated service amperage: 200
Primary service overload protection type: Circuit breakers
Service entrance conductor material: Stranded aluminum
Main disconnect rating (amps): 200
System ground: Copper, Not determined, not readily apparent
Location of main service panel #A: Laundry room
Location of main service panel #B: Garage
Location of main disconnect: Breaker at top of main service panel
Carbon monoxide alarms installed: No, recommend install
Smoke alarm power source(s): Hard wired
32) Ground fault circuit interrupter (GFCI) receptacles wouldn't trip and/or wouldn't trip with a test instrument at the half bathroom. This is a potential shock hazard. Recommend that a qualified electrician evaluate and repair as necessary.
Photo 32-1 Photo 32-2
Photo 32-3
33) Electric receptacles at the kitchen and kitchen island had no visible ground fault circuit interrupter (GFCI) protection, or the inspector was unable to determine if GFCI protection was present. If not GFCI-protected, receptacles in wet areas pose a shock hazard. Recommend that a qualified electrician evaluate and install GFCI protection if necessary and per standard building practices. General guidelines for GFCI-protected receptacles include the following locations:
Outdoors (since 1973)
Bathrooms (since 1975)
Garages (since 1978)
Kitchens (since 1987)
Crawl spaces and unfinished basements (since 1990)
34) The house does not meet current standards. Smoke alarms appeared over 10 years old and some were missing.
Current safety standards recommend smoke alarms should be installed in each bedroom, in hallways leading to bedrooms, and on each level. They have a limited lifespan and should be replaced every 10 years. Batteries in smoke alarms should be changed when taking occupancy and annually in the future. Carbon monoxide alarms should be installed near sleeping areas and on each level in homes with a fuel-burning appliance or attached garage. For more information, visit: http://www.reporthost.com/?SMKALRM http://www.reporthost.com/?COALRM
Photo 34-1 Photo 34-2
Photo 34-3
35) Bare wire ends, or wires with a substandard termination, were found at crawlspace. This is a potential shock hazard. Recommend that a qualified electrician repair as necessary. For example, by cutting wires to length and terminating with wire nuts in a permanently mounted, covered junction box.
Photo 35-1 Photo 35-2
36) Light fixtures were inoperable (didn't turn on when nearby switches were operated). Recommend further evaluation by replacing bulbs and/or consulting with the property owner. If replacing bulbs doesn't work and/or no other switch(es) can be found, then recommend that a qualified electrician evaluate and repair or replace light fixtures as necessary.
Globes or covers for light fixtures were missing or damaged. Recommend replacing as necessary to avoid exposed bulbs. With closet lighting or where flammable stored objects are near light fixtures, missing or broken covers can be a fire hazard.
Photo 36-1 Photo 36-2
Photo 36-3 Photo 36-4
37) Electrical panels were labelled.
Neutral wires were doubled or bundled together under the same lug on the neutral bus bar in the main panel. This was once a common installation method but is considered unacceptable currently due to risks during servicing of the panel. A trained electrician will recognize this when servicing but risk can arise when untrained persons work on the panel. The condition can be corrected relatively easily by a qualified electrician if desired.
Limitations: The following items are not included in this inspection: private/shared wells and related equipment; private sewage disposal systems; hot tubs or spas; main, side and lateral sewer lines; gray water systems; pressure boosting systems; trap primers; incinerating or composting toilets; fire suppression systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determine the existence or condition of underground or above-ground fuel tanks.
Vent pipe material: Plastic
Location of main fuel shut-off valve: At gas meter
Location of main fuel shut-off valve: By furnace
Water service: Public
Water pressure (psi): 60
Location of main water meter: Not determined (obscured, inaccessible or none found)
Location of main water shut-off: Basement
Service pipe material: Galvanized steel
Supply pipe material: Copper
Drain pipe material: Plastic
Waste pipe material: Plastic
Location(s) of plumbing clean-outs: Building exterior
Sewage ejector pump installed: Yes
38) Insulation for some water supply pipes in the crawl space was missing. Recommend replacing or installing insulation on pipes per standard building practices to prevent them from freezing during cold weather, and for better energy efficiency with hot water supply pipes.
Photo 38-1 Photo 38-2
39) A sewage ejector pump was installed on the premises. These are specialty systems. Comments in this report related to this system are made as a courtesy only and are not meant to be a substitute for a full evaluation by a qualified specialist. These systems are typically sealed and involve moving parts. They are subject to clogging and/or damage from disposal of items such as disposable diapers and sanitary napkins. Recommend that this pump and related equipment (piping, valves, etc.) be evaluated by a qualified plumber and repaired if necessary. This should be done per the manufacturer's recommendations in the future, or annually if unable to verify the manufacturer's recommendations. Typically, these pumps have a lifespan of 7-10 years. For more information, visit: http://www.reporthost.com/?SEWEJPMP
Photo 39-1 Photo 39-2
40) Based on visible equipment, this property appeared to have a yard irrigation (sprinkler) system. These are specialty systems and are not a part of a typical home inspection. A recent backflow test tag was not visible. Backflow tests are required annually in many municipalities in our area to prevent cross-contamination of potable water. Recommend asking current owners about test and obtaining work orders if available. If no test has been performed, recommend a qualified specialist perform a backflow test.
Photo 40-1
41) Based on the length of the lines, recommend that a qualified plumber inspect the waste lines using a video scope device to determine if they need repair or replacement. Property owners are usually responsible for repairs to the side sewer and publicly owned lateral lines. Such repairs can be expensive.
Companies such at Lateral Concepts (Brad) at 208-818-8241 provide this service.
One sewer clean out was noted at the side of the house and front of garage/ADU.
Photo 41-1 Photo 41-2
42) Main water shutoff valve is located in the basement.
Photo 42-1
43) Water pressure taken at the house measured 60 PSI. Typical residential water pressure is 40 to 80 PSI.
Location of water heater: Mechanical room, Basement
Hot water temperature tested: Yes
44) The temperature-pressure relief valve drain line was too short. Recommend that a qualified plumber repair per standard building practices. For example, by extending the drain line to within 6 inches of the floor, or routing it to drain outside. For more information, visit: http://www.reporthost.com/?TPRVALVE
Photo 44-1 Photo 44-2
45) The estimated useful life for most water heaters is 8-12 years. This water heater appeared to be at this age and/or its useful lifespan and may need replacing at any time. Recommend budgeting for a replacement in the near future.
Maintaining your water heater for maximum life. See link for more information.
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood-fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating or cooling system components, does not determine if heating or cooling systems are appropriately sized, does not test coolant pressure, or perform any evaluations that require a pilot light to be lit, a shut-off valve to be operated, a circuit breaker to be turned "on" or a serviceman's or oil emergency switch to be operated. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future. Where buildings contain furnishings or stored items, the inspector may not be able to verify that a heat source is present in all "liveable" rooms (e.g. bedrooms, kitchens and living/dining rooms).
General heating system type(s): Forced air, Furnace, Heat pump, Electric heaters, Wood-burning fireplace or stove
General heating distribution type(s): Ducts and registers
Last service date of primary heat source: 2012
Source for last service date of primary heat source: Label
Electric heater type (not forced air): Wall mounted, fan-assisted
Manufacturer of electric heaters (not forced air): Cadet
Forced air heating system fuel type: Natural gas
Estimated age of forced air furnace: 2005
Forced air heating system manufacturer: Lennox
Location of forced air furnace: Basement
Location for forced air filter(s): At base of air handler
Type of combustion air supply: Intake duct, Vent(s) to exterior
Type: Ductless heat pump
Estimated age of heat pump or air conditioning unit: Could not be determined
Manufacturer of cooling system and/or heat pump: Fujitsu
47) Recalled Cadet brand wall heaters were found. Cadet models FW, FX, LX, TK, ZA, Z, RA, RK, RLX, RX, RW and ZC wall heaters have been recalled. The client should ask the property owner if repairs have been made related to the recalls. If so, documentation for the repairs should be reviewed. If not, then a qualified electrician should evaluate and replace or repair heaters as necessary. For more info visit: http://www.cadetco.com/ http://www.reporthost.com/?CADET
Photo 47-1 Photo 47-2
Photo 47-3 Photo 47-4
Photo 47-5 Photo 47-6
48) The ADU heat pump or air conditioning condensing unit did not respond to normal controls (thermostat). It appeared to be inoperable. The inspector was only able to perform a limited evaluation. If possible, consult with the property owner and/or review documentation on this system. Recommend that a qualified HVAC contractor evaluate and perform maintenance or make repairs as necessary.
Photo 48-1 Photo 48-2
Photo 48-3 Photo 48-4
49) Furnace functioning at time of inspection.
The inspector was unable to determine the last service date for the HVAC system. Ask the property owner when it was last serviced. If this system was serviced more than 1 year ago, recommend that a qualified HVAC contractor inspect, clean, and service this system, and make repairs if necessary. For safety reasons, and because this system is fueled by gas, this servicing should be performed annually in the future. Any needed repairs noted in this report should be brought to the attention of the HVAC contractor when it's serviced.
The filter should be changed upon move in. How often a filter should be changed depends on environmental factors (ie pets, smoking, dust, etc) but a general rule of thumb is every 3 months. Adjust time according to observation.
The estimated useful life for most forced air furnaces is 15-20 years, A/C condensing units is 10-15 years.
50) The cover for the heating and/or cooling system air filters were missing. Unfiltered air can enter the return air supply and reduce indoor air quality. Recommend that a qualified person repair as necessary.
The serviceman's switch that controls power to the furnace was not clearly labeled. Recommend permanently labeling this switch to avoid confusion and unintentional loss of power if the switch is mistaken for a light switch.
Photo 50-1 Photo 50-2
51) Heating ducts in an unconditioned space (e.g. crawl space, attic or basement) were not insulated, or the insulation was damaged or deteriorated. This can result in reduced energy efficiency, moisture inside heating ducts, and/or "sweating" on cooling ducts. Recommend that a qualified person repair per standard building practices. For example, by wrapping ducts in insulation with an R-value of R-8.
Photo 51-1 Photo 51-2
52) No central A/C system was installed and no duct work was visible at top floor.
Photo 52-1 Photo 52-2
53) The electric heaters were tested and were in working order at time of inspection. Annual review and cleaning are recommended for safety and function.
Limitations: The following items are not included in this inspection: coal stoves, gas logs, chimney flues (except where visible). Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of drafting or sizing in fireplace and stove flues, and also does not determine if prefabricated or zero-clearance fireplaces are installed in accordance with the manufacturer's specifications. The inspector does not perform any evaluations that require a pilot light to be lit, and does not light fires. The inspector provides a basic visual examination of a chimney and any associated wood burning device. The National Fire Protection Association has stated that an in-depth Level 2 chimney inspection should be part of every sale or transfer of property with a wood-burning device. Such an inspection may reveal defects that are not apparent to the home inspector who is a generalist.
Wood-burning fireplace type: Ceramic and masonry
Fan or blower installed in wood-burning fireplace or stove: Not determined (inaccessible or obscured)
Wood-burning chimney type: Masonry
54) Minor cracks and spalling was found in the chimney crown. Client should seal cracks. Numerous products exist to seal such cracks including hydraulic cement, non-shrinking grout, resilient caulks and epoxy sealants.
No spark screen or rain cap was installed at the chimney flue terminations. Spark screens reduce the chance of embers exiting the flue and causing fires. They also prevent wildlife (e.g. birds, rodents, raccoons) from entering flues. Rain caps prevent water from entering flues, mixing with combustion deposits and creating caustic chemicals which can corrode flues. They also prevent damage to masonry from freeze-thaw cycles and prevent metal components (e.g. dampers, metal firebox liners) from rusting. Recommend that a qualified person install rain caps with spark screens per standard building practices where missing.
Photo 54-1 Photo 54-2
Photo 54-3
55) Wood-burning fireplaces or stoves were found at the property. Before such devices are used, they should be professionally cleaned and inspected by a qualified specialist. This should occur annually to prevent creosote build-up and to determine if repairs are needed. For more information, search for "chimney inspection" at: http://www.reporthost.com/?CSIA
Limitations: The following items are not included in this inspection: household appliances such as stoves, ovens, cook tops, ranges, dishwashers, refrigerators, freezers, ice makers, hot water dispensers and water filters; Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances. The inspector does not note appliance manufacturers, models or serial numbers and does not determine if appliances are subject to recalls. Areas and components behind and obscured by appliances are inaccessible and excluded from this inspection.
Condition of sinks and related plumbing: Serviceable.
Condition of under-sink food disposal: Appears serviceable
Condition of dishwasher: Appears serviceable.
Condition of range, cooktop or oven: Appears serviceable.
Range, cooktop or oven type: Natural gas
Condition of refrigerator: Appeared serviceable
Condition of built-in microwave oven: A counter top microwave was noted in the kitchen
56) The estimated useful life for most kitchen appliances is 10-15 years. Appliances appeared to be near, at or beyond their service life. Even if operable, recommend budgeting for replacements in the near future.
Inspector performs a limited function test of appliances and runs dishwasher for short cycle. Deficiencies at time of inspection are noted above if present.
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Location #A: Full bath, second floor
Location #B: Full bath, Master bath, first floor
Location #C: Half bath, first floor
Location #D: Laundry room/area, first floor
Location #E: ADU
Condition of counters: Serviceable.
Condition of cabinets: Appeared serviceable
Condition of flooring: Satisfactory
Condition of sinks and related plumbing: Serviceable.
Condition of toilets: Serviceable.
Condition of bathtubs and related plumbing: Serviceable.
Condition of shower(s) and related plumbing: Serviceable.
Condition of ventilation systems: Satisfactory
Bathroom and laundry ventilation type: Spot exhaust fans, with individual ducts
Gas supply for laundry equipment present: Not determined
240 volt receptacle for laundry equipment present: Not determined
57) The clothes dryer exhaust duct was broken in crawlspace. Clothes dryers produce large amounts of moisture which should not enter structure interiors. Moisture can accumulate and result in mold, bacteria or fungal growth. Recommend that a qualified person make permanent repairs as necessary. For more information, visit: http://www.reporthost.com/?DRYER
The clothes dryer was equipped with a vinyl or mylar, accordion-type, flexible exhaust duct. The U.S. Consumer Product Safety Commission considers these types of ducts to be unsafe, and a fire hazard. They can trap lint and are susceptible to kinks or crushing, which can greatly reduce the air flow and cause overheating. Recommend that such ducts be replaced with a rigid or corrugated semi-rigid metal duct, and by a qualified contractor if necessary.
58) A significant amount of water came out of the bathtub spout when the shower at location(s) #A was turned on. The diverter valve is likely defective, or may be encrusted with mineral deposits. Water will be wasted as a result. Recommend that a qualified plumber repair or replace components as necessary.
Photo 58-1 Photo 58-2
59) No access or only limited access was available to the back of the clothes washer and dryer, and to utility hook-ups located behind the appliances. The inspector normally attempts to determine the presence of a gas vs. electric power supply, the configuration of the stand pipe, whether the dryer exhaust duct is serviceable, etc. Because of the lack of access, the inspector was unable to fully evaluate and/or describe the hook-ups and appliances.
Recommend clearing dryer duct of lint upon move in and periodically in the future to reduce fire hazard. Dryer vent should be as straight and short as possible to minimize lint collection.
Photo 59-1 Photo 59-2
60) Inspector ran water in the sink(s) and bathtub(s). Ran shower water and flushed toilet(s). No leaks were noted at time of inspection.
Photo 60-1 Photo 60-2
Photo 60-3 Photo 60-4
Photo 60-5 Photo 60-6
Photo 60-7 Photo 60-8
Photo 60-9 Photo 60-10
61) The jetted tub was in working order at time of inspection. The tub was on a GFCI circuit.
The equipment for the jetted bathtub was inaccessible (e.g. no access hatch, permanently installed hatch, unusual fasteners for hatch). As a result, the inspector was unable to evaluate the jetted bathtub's electrical and mechanical equipment.
Debris came out of the jets when the jetted bathtub was turned on. Some jetted tub designs allow water to stagnate in pipes, resulting in mold or bacteria growth that is expelled from jets. It's unlikely that repairs or modifications can be made to prevent this if it is occurring. It may be possible to prevent such biological growth by running hot water and bleach or dishwasher soap (low sudsing) through the jetted bathtub periodically. For more information, visit: http://www.reporthost.com/?MOLDJETS
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; cosmetic deficiencies such as nail-pops, scuff marks, dents, dings, blemishes or issues due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window, drawer, cabinet door or closet door operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Determining the cause and/or source of odors is not within the scope of this inspection.
Type(s) of windows: Wood, Multi-pane, Casement
Exterior door material: Wood, Metal, Glass panel, Sliding glass
Condition of interior doors: Satisfactory
Type(s) of windows: Wood
Wall type or covering: Drywall
Ceiling type or covering: Drywall, Wood & beam
Condition of flooring: Satisfactory
Flooring type or covering: Carpet, Vinyl, linoleum or marmoleum, Wood or wood products
Condition of stairs, handrails and guardrails: Satisfactory
62) Condensation or staining was visible between multi-pane glass in most windows, skylight, and sliding door windows. This usually indicates that the seal between the panes of glass has failed or that the desiccant material that absorbs moisture is saturated. As a result, the view through the window may be obscured, the window's R-value will be reduced, and accumulated condensation may leak into the wall structure below. Recommend that a qualified contractor evaluate and repair windows as necessary. Usually, this means replacing the glass in window frames.
Be aware that evidence of failed seals or desiccant may be more or less visible depending on the temperature, humidity, sunlight, etc. Windows or glass-paneled doors other than those that the inspector identified may also have failed seals and need glass replaced. It is beyond the scope of this inspection to identify every window with failed seals or desiccant.
Photo 62-1 Photo 62-2
Photo 62-3 Photo 62-4
Photo 62-5 Photo 62-6
Photo 62-7 Photo 62-8
Photo 62-9 Photo 62-10
63) The open-close mechanisms for many casement windows were difficult to operate, inoperable or damaged. Recommend that a qualified person repair as necessary.
Photo 63-1 Photo 63-2
Photo 63-3 Photo 63-4
Photo 63-5 Photo 63-6
Photo 63-7 Photo 63-8
64) Glass in master bathroom window was cracked, broken and/or missing. Recommend that a qualified contractor replace glass where necessary.
Photo 64-1 Photo 64-2
Photo X-1 Photo X-2
Photo X-3 Photo X-4
Photo X-5 Photo X-6
Photo X-7 Photo X-8
Photo X-9 Photo X-10
Photo X-11 Photo X-12
Photo X-13 Photo X-14
Photo X-15 Photo X-16
Photo X-17 Photo X-18
Photo X-19 Photo X-20
Photo X-21 Photo X-22
Photo X-23 Photo X-24
Photo X-25 Photo X-26
Photo X-27 Photo X-28
Photo X-29 Photo X-30
Photo X-31 Photo X-32
Photo X-33 Photo X-34
Photo X-35 Photo X-36
Photo X-37 Photo X-38
Photo X-39 Photo X-40
Photo X-41 Photo X-42
Photo X-43 Photo X-44
Photo X-45 Photo X-46
Photo X-47 Photo X-48
Photo X-49 Photo X-50
Photo X-51 Photo X-52
Photo X-53 Photo X-54
Photo X-55 Photo X-56
Photo X-57 Photo X-58
Photo X-59 Photo X-60
Photo X-61 Photo X-62
Photo X-63 Photo X-64
Photo X-65 Photo X-66
Photo X-67 Photo X-68
Photo X-69 Photo X-70
Photo X-71 Photo X-72
Photo X-73 Photo X-74
Photo X-75 Photo X-76
Photo X-77 Photo X-78
Photo X-79 Photo X-80
Photo X-81 Photo X-82
Photo X-83 Photo X-84
Photo X-85 Photo X-86
Photo X-87 Photo X-88
Photo X-89 Photo X-90
Photo X-91 Photo X-92
Photo X-93 Photo X-94
Photo X-95 Photo X-96
Photo X-97 Photo X-98
Photo X-99 Photo X-100
Photo X-101 Photo X-102
Photo X-103 Photo X-104
Photo X-105 Photo X-106
Photo X-107 Photo X-108
Photo X-109 Photo X-110
Photo X-111 Photo X-112
Photo X-113 Photo X-114
Photo X-115 Photo X-116
Photo X-117 Photo X-118
Photo X-119 Photo X-120
Photo X-121 Photo X-122
Photo X-123 Photo X-124
Photo X-125 Photo X-126
Photo X-127 Photo X-128
Photo X-129 Photo X-130
Photo X-131 Photo X-132
Photo X-133 Photo X-134
Photo X-135 Photo X-136
Photo X-137 Photo X-138
Photo X-139 Photo X-140
Photo X-141 Photo X-142
Photo X-143 Photo X-144
Photo X-145 Photo X-146
Photo X-147 Photo X-148
Photo X-149 Photo X-150
Photo X-151 Photo X-152
Photo X-153 Photo X-154
Photo X-155
This report is not a guaranty or warranty. Anything can fail at any time. This inspection report is only reporting on the conditions as observed at the time of the inspection, and is not intended to be considered as a guaranty or warranty, expressed or implied, of the adequacy of, or performance of, systems or structures, or their component parts, or of their remaining life expectancy or usefulness. Systems, equipment and components can, and do, fail—randomly and without prior warning.
Please review your pre-inspection agreement We appreciate the opportunity to be of service. Should you have any questions about the general condition of the house in the future, we would be happy to answer these. There is no fee for this telephone consulting. Our fees are based on a single visit to the property. If additional visits are required for any reason, additional fees may be assessed.