View as PDF

View summary

Logo

Faithful Home Inspections LLC

6160 Firestone Blvd Unit 104-107 
Firestone, CO 80504
Inspector: Kyle Allen
Inspector's email: faithfulhomeinspections@gmail.com
Inspector's phone: (303) 919-1782
U.S. Home Inspector Training Completion Certificate #629577

1yr Warranty Inspection example

Client(s):  New home owners
Property address:  33333 Main St.
Inspection date:  Friday, September 27, 2024

This report published on Sunday, September 29, 2024 11:07:21 AM MDT

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

A general home inspection is a non-invasive, visual examination of the accessible areas of a residential property, performed for a fee, which is designed to identify defects within specific systems and components that are both observed and deemed material by the inspector. It is based on the observations made on the date of the inspection, and not a prediction of future conditions. It is a snapshot in time. A general home inspection will not reveal every issue that exists or ever could exist, but only those material defects observed on the date of the inspection.

How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
Concern typeSafetyPoses a safety hazard
Concern typeRepair/ReplaceRecommend repairing or replacing
Concern typeRepair/MaintainRecommend repair and/or maintenance
Concern typeMaintainRecommend ongoing maintenance
Concern typeEvaluateRecommend evaluation by a specialist
Concern typeMonitorRecommend monitoring in the future
Concern typeCommentFor your information

Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp

Table of Contents

General Information
Grounds
Exterior and Foundation
Roof
Attic and Roof Structure
Garage or Carport
Electric
Plumbing / Fuel Systems
Water Heater
Heating, Ventilation and Air Condition (HVAC)
Kitchen
Bathrooms, Laundry and Sinks
Interior, Doors and Windows

View summary

General Information
Table of contents
Report number: 092720241
Time started: 9:00am
Time finished: 1:00pm
Present during inspection: Client, Property owner
Client present for discussion at end of inspection: Yes
Weather conditions during inspection: Dry (no rain), Sunny
Temperature during inspection: Warm
Ground condition: Dry
Recent weather: Dry (no rain), Rain, Sunny
Overnight temperature: Cool
Inspection fee: 375
Payment method: Credit card
Type of building: Townhouse
Buildings inspected: One condominium unit
Number of residential units inspected: 1
Age of main building: 1
Source for main building age: Client, Property owner
Front of building faces: West
Main entrance faces: West
Occupied: Yes, Furniture or stored items were present
1) One or more hornet, bee or wasp nests were found at the building exterior. These can pose a safety hazard. A qualified person should remove nests or exterminate as necessary.
Photo
Photo 1-1 Insect nests above garage.
Photo
Photo 1-2 Nests at East side above garage.
2) The client should be aware that a break-in period occurs during the first year or two after a building is constructed. Some amount of settlement and shrinkage is inevitable as temperature and humidity varies during the seasons. Systems may need adjustment or repair after experiencing constant, prolonged and/or heavy usage. Overall performance of the building exterior has not yet been tested by a wide variety of weather conditions.

Also, it is beyond the scope of this inspection to determine if all permits have been approved or signed off. Consult with the builder and/or municipality to determine if all necessary permits have been approved.
Limitations: Unless specifically included in the inspection, the following items and any related equipment, controls, electric systems and/or plumbing systems are excluded from this inspection: detached buildings or structures; fences and gates; retaining walls; underground drainage systems, catch basins or concealed sump pumps; swimming pools and related safety equipment, spas, hot tubs or saunas; whether deck, balcony and/or stair membranes are watertight; trees, landscaping, properties of soil, soil stability, erosion and erosion control; ponds, water features, irrigation or yard sprinkler systems; sport courts, playground, recreation or leisure equipment; areas below the exterior structures with less than 3 feet of vertical clearance; invisible fencing; sea walls, docks and boathouses; retractable awnings. Any comments made regarding these items are as a courtesy only.
Site profile: Level
Condition of driveway: Appeared serviceable
Driveway material: Poured in place concrete
Condition of sidewalks and/or patios: Required repairs, replacement and/or evaluation (see comments below)
Sidewalk material: Poured in place concrete
Deck, patio, porch cover material and type: Covered (Refer to Roof section)
Condition of stairs, handrails and guardrails: Appeared serviceable, Required repairs, replacement and/or evaluation (see comments below)
Exterior stair material: Wood
3) Cracks, holes, protrusions, settlement, heaving and/or deterioration resulting in trip hazards were found in the driveway. For safety reasons, recommend that a qualified contractor repair as necessary.
Photo
Photo 3-1 Metal studs protruding in driveway.
4) One or more drains in the yard or landscaped areas appeared to be damaged. Water may accumulate and become a nuisance, or may flow towards the building. Recommend that a qualified person clear drains as necessary.
Photo
Photo 4-1 Underground gutter drain pipe punctured, SW corner.
5) Cracks, holes, settlement, heaving and/or deterioration were found in sidewalks and/or patios. Recommend that qualified contractor repair as necessary.
Photo
Photo 5-1 Front porch hairline crack, #1.
Photo
Photo 5-2 Front porch hairline crack, #2.
Photo
Photo 5-3 Front porch hairline crack, #3.
6) This property was accessed by a driveway or private road shared with nearby properties. Shared driveways or private roads are excluded from this inspection. Comments in this report related to them are made as a courtesy only and are not meant to be a substitute for a evaluation by a specialist if repairs are needed. Recommend that the client review the recorded agreements regarding the driveway, the deeds of the property owners involved, and easements permitting access to, use of, and maintenance of the driveway.
Exterior and Foundation
Table of contents
Limitations: The inspector performs a visual inspection of accessible components or systems at the exterior. Items excluded from this inspection include below-grade foundation walls and footings; foundations, exterior surfaces or components obscured by vegetation, stored items or debris; wall structures obscured by coverings such as siding or trim. Some items such as siding, trim, soffits, vents and windows are often high off the ground, and may be viewed using binoculars from the ground or from a ladder. This may limit a full evaluation. Regarding foundations, some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determine the adequacy of seismic reinforcement.
Wall inspection method: Viewed from ground, from a ladder
Condition of wall exterior covering: Appeared serviceable
Apparent wall structure: Wood frame
Wall covering: Wood fiber, Solid brick (not veneer)
Condition of foundation and footings: Not determined
Apparent foundation type: Concrete slab on grade, Concrete garage slab
Foundation/stem wall material: Poured in place concrete
7) The masonry (brick or stone) veneer was deteriorated or damaged in some areas. Where cracks or openings are exposed, water may enter the wall structure causing mold, fungal growth and structural damage. This is a conducive condition for wood-destroying organisms. Recommend that a qualified contractor repair as necessary. For example, by repointing mortar or replacing broken or missing masonry.
Photo
Photo 7-1 Hairline crack above front elevation main floor window.
Photo
Photo 7-2 Hairline crack below front elevation main floor window.
8) One or more sections of horizontal trim boards had no "Z" flashing installed above them where they met siding. "Z" flashing should be installed above these boards to reduce the chance of leaks and/or water entrapment between the trim and siding. Without this flashing, caulk and paint must be diligently maintained, or water can cause rot and possible structural damage. Recommend that a qualified contractor install flashing above horizontal trim boards where missing and per standard building practices. Note that when trim or siding is removed to install flashing, damaged wood may be found and additional repairs may be needed.
Photo
Photo 8-1 Front elevation, 2nd story top window trim.
9) This property was clad with composition wood-fiber siding. Various manufacturers (e.g. Louisiana Pacific, Weyerhaeuser and Masonite) have produced this type of siding, which is made from oriented strand board (OSB) or "hardboard." It is prone to deteriorate and/or fail prematurely due to moisture penetration, especially when the paint coating is substandard or has not been maintained. Failure is typically visible in the form of swelling, cracking, buckling, wafer pops, delamination and fungal growth.

Some areas of siding on this structure showed symptoms described above and need replacement and/or maintenance. Some manufacturers (e.g. Louisiana Pacific) recommend a repair process for this siding where affected areas are sealed with Permanizer Plus, a flexible primer made by Pittsburgh Paint, followed by two coats of 100% acrylic latex paint. This sealant must be applied to the bottom edges using a brush. The face of the siding can be sprayed. The Permanizer Plus sealer isn't required for edges that aren't swollen, cracked or deteriorated, but the acrylic latex should still be brushed on these edges.

Recommend that a qualified contractor evaluate and replace siding as necessary, and/or seal and repaint as necessary. Repairs should be made per the siding and/or sealant manufacturer's installation instructions, and per standard building practices.

For more information, visit:
https://www.reporthost.com/?PERMPLUS
https://www.reporthost.com/?COMPSDNG
Photo
Photo 9-1 Cracked siding, below window on South side.
Photo
Photo 9-2 Cracked siding, East side of property by service line entrance.
10) Untreated wood siding and/or trim was in contact with concrete or masonry at the exterior. Moisture collected between the two materials or wicking up into the wood is a conducive condition for wood-destroying organisms. Wood siding or trim should be installed with a minimum clearance of 1-2 inches between it and concrete or masonry below it at building exteriors. Monitor these areas for rot or infestation in the future and repair if needed. Recommend that a qualified person repair per standard building practices. For example, by trimming siding or trim as needed.
Photo
Photo 10-1 2X4 left in ground, NE corner of property.
11) The paint or stain finish in some areas was failing (e.g. peeling, faded, worn, thinning). Siding and trim with a failing finish can be damaged by moisture. Recommend that a qualified contractor prep (e.g. clean, scrape, sand, prime, caulk) and repaint or restain the building exterior where necessary and per standard building practices. Any repairs needed to the siding or trim should be made prior to this.
Photo
Photo 11-1 Paint defects on siding, South side.
12) Caulk and/or paint was missing, deteriorated and/or substandard in some areas. For example, around windows, around doors and/or at wall penetrations. Recommend that a qualified person renew or install caulk as necessary. Where gaps are wider than 1/4 inch, an appropriate material other than caulk should be used. For more information, visit:
https://www.reporthost.com/?CAULK
Photo
Photo 12-1 Front elevation, bottom of window trim.
Photo
Photo 12-2 Trim gap above garage door.
Photo
Photo 12-3 Gas line entrance, SE corner.
Photo
Photo 12-4 Front door, right side.
Photo
Photo 12-5 Front elevation window trim caulk gap.
13) Efflorescence was observed in some areas on brick walls. This is signs of excessive water in the area. Recommend monitoring the area.
Photo
Photo 13-1 Efflorescence below front elevation main floor window.
14) Some above-grade foundation walls were obscured by stored items. The inspector was unable to evaluate these areas. They are excluded from this inspection.
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; solar roofing components. Any comments made regarding these items are made as a courtesy only. Note that the inspector does not provide an estimate of remaining life on the roof surface material, nor guarantee that leaks have not occurred in the roof surface, skylights or roof penetrations in the past. Regarding roof leaks, only active leaks, visible evidence of possible sources of leaks, and evidence of past leaks observed during the inspection are reported on as part of this inspection. The inspector does not guarantee or warrant that leaks will not occur in the future. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high wind and rain, melting snow) would be needed to do so. Occupants should monitor the condition of roofing materials in the future. For older roofs, recommend that a professional inspect the roof surface, flashings, appurtenances, etc. annually and maintain/repair as might be required. If needed, the roofer should enter attic space(s). Regarding the roof drainage system, unless the inspection was conducted during and after prolonged periods of heavy rain, the inspector was unable to determine if gutters, downspouts and extensions perform adequately or are leak-free.
Age of roof surface(s): 1
Roof inspection method: Traversed
Condition of roof surface material: Appeared serviceable
Roof surface material: Asphalt or fiberglass composition shingles
Roof type: Gable
Apparent number of layers of roof surface material: One
Condition of exposed flashings: Appeared serviceable, Required repair, replacement and/or evaluation (see comments below)
Condition of gutters, downspouts and extensions: Appeared serviceable
Gutter and downspout material: Metal, Plastic
15) Extensions such as splash blocks or drain pipes for one or more downspouts were damaged. Water can accumulate around the building foundation or inside crawl spaces or basements as a result. Recommend that a qualified person install, replace or repair extensions as necessary so rainwater drains away from the structure.
16) Substandard caulking was observed in one or more areas of flat metal roofing. Recommend that a qualified roofing contractor evaluate and repair in necessary.
Photo
Photo 16-1 Flat roof section caulking seam.
17) Gaps were found in or around roof soffits and can allow birds or vermin to enter the attic. Recommend that a qualified person repair as necessary to eliminate gaps.
Photo
Photo 17-1 SW corner, flat roof section, gap to siding.
18) One or more roof flashings and/or caulking gaps were substandard. Leaks can occur as a result. This is a conducive condition for wood-destroying organisms and water damage. Recommend that a qualified person repair as necessary.
Photo
Photo 18-1 SW corner, fascia gap.
19) Shingles were observed on flashing. This can inhibit the flashings function to effectively shed water from the building's siding. Recommend that a qualified contractor evaluate.
Photo
Photo 19-1 Front porch cover.
20) One or more downspouts terminated above a roof surface, and rainwater from the downspouts washes over the roof surface below. This is a common configuration, but in some cases large quantities of rainwater can damage shingles by removing granules and reduce the life of the roof surface. Consider installing extensions to route the rainwater directly to the closest gutter below to prevent such damage.
Photo
Photo 20-1 Front elevation gutter above porch, NW corner.
Attic and Roof Structure
Table of contents
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation. Any comments made regarding these items are made as a courtesy only. The inspector does not determine the adequacy of the attic ventilation system. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high/low temperatures, high/low humidity, high wind and rain, melting snow) would be needed to do so. The inspector is not a licensed engineer and does not determine the adequacy of roof structure components such as trusses, rafters or ceiling beams, or their spacing or sizing.
Attic inspection method: Traversed
Location of attic access point #A: Hallway, second floor, east
Attic access points that were opened and viewed, traversed or partially traversed: A
Roof structure type: Trusses
Ceiling structure: Trusses
Ceiling insulation material: Fiberglass roll or batt, Spray polyurethane foam
Approximate attic insulation R value (may vary in areas): Not determined (inaccessible or obscured)
Vapor retarder: None
Roof ventilation type: Mechanical vents with powered fan
21) In one or more areas a gap was observed in the wall top plate. All gaps should be sealed by a qualified contractor to prevent drafts and fire pathways.
Photo
Photo 21-1 Gap in top plate on North wall in attic.
22) One or more attic access hatches or doors were not insulated, or had substandard insulation. Weather-stripping was also missing or substandard. Recommend installing weather-stripping and insulation per current standards at hatches or doors for better energy efficiency. For more information, visit:
https://www.reporthost.com/?ATTACC
Photo
Photo 22-1 Attic hatch lip.
23) The ceiling insulation in one or more areas of the attic was missing. Heating and cooling costs may be higher due to reduced energy efficiency. Recommend that a qualified person repair, replace or install insulation as necessary and per standard building practices (typically R-38).
Photo
Photo 23-1 Missing insulation on West end of attic.
Garage or Carport
Table of contents
Limitations: The inspector cannot reasonably determine the integrity of all elements of limited fire resistance at residential construction or verify firewall ratings at multi unit construction. Requirements for ventilation in garages vary between municipalities.
Type: Attached
Condition of door between garage and house: Appeared serviceable
Type of door between garage and house: Solid core
Type of garage vehicle door: Sectional
Number of vehicle doors: 1
Mechanical auto-reverse operable (reverses when meeting reasonable resistance during closing): Yes
Garage ventilation: None visible
24) The self-closing device on the door between the garage and the house didn't close and latch the door. These devices are installed to keep the door closed to prevent possible fire and fumes from the garage from spreading to the house. Recommend that a qualified person repair as necessary.
Photo
Photo 24-1 Garage door not self closing.
25) The photoelectric sensors that trigger the auto-reverse feature on one or more garage vehicle doors' automatic openers were located higher than 4-6 inches from the floor. This is a potential safety hazard. A qualified person should relocate sensors so they are 4-6 inches from the floor per standard building practices. For more information on garage door safety issues, visit:
https://www.reporthost.com/?GDPES
Photo
Photo 25-1 Garage door sensors too high.
26) The lock mechanism on one or more garage vehicle doors was inoperable or difficult to operate or is not actually able to lock the vehicle door. Recommend that a qualified person repair as necessary so the door(s) can be easily secured.
27) Significant gaps were found below or around one or more garage vehicle doors. Vermin and insects can enter the garage as a result. Recommend that a qualified person repair as necessary to eliminate or minimize gaps.
Photo
Photo 27-1 Garage door trim defect, North end.
Limitations: The following items are not included in this inspection: generator systems, transfer switches, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low-voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, if this system has an adequate capacity for the client's specific or anticipated needs, or if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, and does not install or change light bulbs. The inspector does not evaluate every wall switch or receptacle, but instead tests a representative number of them per various standards of practice. When furnishings, stored items or child-protective caps are present some receptacles are usually inaccessible and are not tested; these are excluded from this inspection. Receptacles that are not of standard 110 volt configuration, including 240-volt dryer receptacles, are not tested and are excluded. The functionality of, power source for and placement of smoke and carbon monoxide alarms is not determined as part of this inspection. Upon taking occupancy, proper operating and placement of smoke and carbon monoxide alarms should be verified and batteries should be changed. These devices have a limited lifespan and should be replaced every 10 years. The inspector attempts to locate and evaluate all main and sub-panels. However, panels are often concealed. If panels are found after the inspection, a qualified electrician should evaluate and repair if necessary. The inspector attempts to determine the overall electrical service size, but such estimates are not guaranteed because the overall capacity may be diminished by lesser-rated components in the system. Any repairs recommended should be made by a licensed electrician.
Number of service conductors: 3
Service voltage (volts): 120-240
Primary service overload protection type: Circuit breakers
Service entrance conductor material: Stranded aluminum
Main disconnect rating (amps): 150
System ground: Not determined, not readily apparent
Condition of main service panel: Appeared serviceable
Location of main service panel #A: Garage
Location of main disconnect: Breaker at bottom of main service panel
Branch circuit wiring type: non-metallic sheathed
Ground fault circuit interrupter (GFCI) protection present: Yes
Smoke alarms installed: Installed and appear to be functioning properly at this time
Carbon monoxide alarms installed: Yes and appeared to be working property at this time
28) Neutral and ground wires did not appear to be bonded together at the main service panel. In the main service panel, neutrals and grounds should be connected (bonded) to each other and to the metal panel housing. This is a safety hazard for shock. Recommend that a qualified electrician evaluate and repair per standard building practices.
29) Components for the grounding system were substandard. This is a potential safety hazard due to the risk of shock. Recommend that a qualified electrician evaluate and repair as necessary.
Photo
Photo 29-1 Service panel grounding cable.
30) One or more electric receptacles at the bathroom(s) had no visible ground fault circuit interrupter (GFCI) protection, or the inspector was unable to determine if GFCI protection was present. If not GFCI-protected, receptacles in wet areas pose a shock hazard. Recommend that a qualified electrician evaluate and install GFCI protection if necessary and per standard building practices. General guidelines for GFCI-protected receptacles include the following locations:
  • Outdoors (since 1973)
  • Bathrooms (since 1975)
  • Garages (since 1978)
  • Kitchens (since 1987)
  • Crawl spaces and unfinished basements (since 1990)
  • Wet bar sinks (since 1993)
  • Laundry and utility sinks (since 2005)
For more information, visit:
https://www.reporthost.com/?GFCI
Photo
Photo 30-1 Bathroom outlet near sink without GFCI visible.
31) Non-metallic sheathed wiring in the attic was routed on surfaces within 6 feet of one or more access hatches or doors, and was subject to damage. Wiring can be damaged when hatches are lifted and set aside, when stored items are moved into or out of the attic, etc. This is a potential shock and/or fire hazard. Recommend that a qualified electrician repair per standard building practices.
Photo
Photo 31-1 Wire near attic hatch.
32) One or more light fixtures installed outside were loose. This is a potential shock and/or fire hazard. Recommend that a qualified electrician repair as necessary.
Photo
Photo 32-1 Loosely attached sconce light, two by garage door and one by front door.
33) One or more wires were protruding out of a grounding bar shield. Recommend that a qualified electrician trim back the wire to within the shield.
Photo
Photo 33-1 Exposed ground wire, East side by service line entrance.
34) In one or more bathroom, a light was located directly above the shower. These lights need to be rated for wet conditions. Recommend that a qualified electrician evaluate the light for safety concerns.
Photo
Photo 34-1 Light above master shower.
35) The functionality of, power source for and placement of smoke alarms is not determined as part of this inspection. Smoke alarms should be installed in each bedroom, in hallways leading to bedrooms, on each level and in attached garages. They have a limited lifespan and should be replaced every 10 years. For home buyers, batteries in smoke alarms should be changed when taking occupancy. Batteries should be replaced annually in the future. Carbon monoxide alarms should be installed in the vicinity of sleeping areas and on each level. For more information, visit:
https://www.reporthost.com/?SMKALRM
https://www.reporthost.com/?COALRM
36) The electric service to this property appeared to be rated at substantially less than 200 amps and may be inadequate. Depending on the client's needs, recommend consulting with a qualified electrician about upgrading to a 200 amp service. Note that the electric service's rating is based on the lowest rating for the meter base, the service conductors, the main service panel and the main disconnect switch. One or more of these components may need replacing to upgrade.
Photo
Photo 36-1 Service panel without deadfront.
Plumbing / Fuel Systems
Table of contents
Limitations: The following items are not included in this inspection: private/shared wells and related equipment; private sewage disposal systems; hot tubs or spas; main, side and lateral sewer lines; gray water systems; pressure boosting systems; trap primers; incinerating or composting toilets; fire suppression systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determine the existence or condition of underground or above-ground fuel tanks.
Location of main water meter: Not determined (obscured, inaccessible or none found)
Location of main water shut-off: Not determined (obscured, inaccessible or none found)
Service pipe material: Not determined (inaccessible or obscured)
Supply pipe material: PEX plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
Location(s) of plumbing clean-outs: Bathroom by kitchen, wall panel
Vent pipe material: Plastic
Sump pump installed: None visible
37) Steel piping for the gas service located outside was significantly corroded. Gas leaks can result. Recommend evaluation by a qualified contractor to determine if piping needs replacing. If not, then a qualified person should prep and paint lines as necessary with a rust-preventative paint. Very corroded pipes should be replaced by a qualified contractor.
Photo
Photo 37-1 Gas pipe paint deteriorated, SE corner.
38) The inspector did not determine the location of the water meter. Recommend consulting with the property owner to determine the meter location, that you locate it yourself, or consult with the local water municipality if necessary. It is especially important to find the meter if no main shut-off valve is found because the meter may be the only way to turn off the water supply in the event of an emergency, such as when a supply pipe bursts.
39) The inspector did not determine the location of the main water shut-off valve, or verify that a readily accessible shut-off valve in the building exists. Recommend consulting with the property owner to determine if a main shut-off valve exists, locating it yourself, or that a qualified plumber find it if necessary. If no readily accessible main shut-off valve is found in the building, then recommend that a qualified plumber install one so the water supply can be quickly turned off in the event of an emergency, such as when a supply pipe bursts.
Water Heater
Table of contents
Limitations: Evaluation of and determining the adequacy or completeness of the following items are not included in this inspection: water recirculation pumps; solar water heating systems; Energy Smart or energy saver controls; catch pan drains. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit or a shut-off valve to be operated.
Type: Tankless
Energy source: Natural gas
Temperature-pressure relief valve installed: Yes
Manufacturer: Rinnai
Location of water heater: Laundry room
Hot water temperature tested: Yes
Water temperature (degrees Fahrenheit): 100
40) One or more tankless water heaters were observed at this property. It is beyond the scope of this inspection to determine the adequacy of this system since demand varies significantly with water usage. For example, with simultaneous showers while washing clothes or dishes, etc. During such usage, tankless water heaters may not keep up with demand. This inspection includes a limited evaluation of the water heater to determine the following:
  • Does it supply hot water?
  • Is the water pressure adequate for the unit (typically minimum 30-50 psi)?
  • If fuel-fired, is combustion air and the venting system serviceable?
  • Is the wiring for the electric supply safe?
  • If required, is a temperature-pressure relief valve and drain line installed?
Any concerns observed related to the above items are noted in this report.
Photo
Photo 40-1 Hot water heater.
Photo
Photo 40-2 Kitchen sink hot water temperature.
Heating, Ventilation and Air Condition (HVAC)
Table of contents
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood-fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating or cooling system components, does not determine if heating or cooling systems are appropriately sized, does not test coolant pressure, or perform any evaluations that require a pilot light to be lit, a shut-off valve to be operated, a circuit breaker to be turned "on" or a serviceman's or oil emergency switch to be operated. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future. Where buildings contain furnishings or stored items, the inspector may not be able to verify that a heat source is present in all "liveable" rooms (e.g. bedrooms, kitchens and living/dining rooms).
General heating system type(s): Forced air
General heating distribution type(s): Ducts and registers
Forced air heating system fuel type: Natural gas
Forced air heating system manufacturer: Carrier
Location of forced air furnace: Mechanical room
Condition of furnace filters: Required replacement
Location for forced air filter(s): At base of air handler
Condition of forced air ducts and registers: Required repair, replacement and/or evaluation (see comments below)
41) One or more possible leaks were found at the furnace's heat exchanger. This is a safety hazard due to possibility of combustion gases entering the heating system's air supply ducts. Recommend that a qualified HVAC contractor evaluate and repair as necessary.
Photo
Photo 41-1 Furnace, under blower fan.
42) One or more heating or cooling ducts have come apart, or had significant gaps at junctions. This can result in reduced energy efficiency and increased moisture in surrounding spaces. Recommend that a qualified HVAC contractor make permanent repairs as necessary. For example, by securely supporting ducts and installing approved tape or mastic at seams.
Photo
Photo 42-1 Large hole in duct work in attic.
43) One or more heating or cooling ducts were kinked. This can result in reduced energy efficiency. Recommend that qualified HVAC contractor repair or replace ducts or components as necessary.
Photo
Photo 43-1 Kinked duct tube on SW corner of attic.
44) It was observed that one or more exterior vent flaps were stuck open. Recommend that a qualified person evaluated and repair to prevent any intrusion of insects or birds, etc.
Photo
Photo 44-1 Vent flap stuck open, East side above service line entrance.
45) The pad for the heat pump or air conditioning condensing unit was not level. This unit requires adequate support. The compressor may be damaged if this unit is tilted 10 degrees or more. Also, the pad should elevate the unit above the soil to prevent corrosion. Recommend that a qualified person repair as necessary.
Photo
Photo 45-1 A/C condenser unit not level.
46) Ductwork in one or more locations had a damper without a motor. This can cause sections/zones to be blocked or exposed to conditioned air that aren't meant to be. Recommend that a qualified contractor repair any dampers without motors.
Photo
Photo 46-1 Damper without motor on South side of attic duct tube.
Limitations: The following items are not included in this inspection: household appliances such as stoves, ovens, cook tops, ranges, warming ovens, griddles, broilers, dishwashers, trash compactors, refrigerators, freezers, ice makers, hot water dispensers and water filters; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances. The inspector does not note appliance manufacturers, models or serial numbers and does not determine if appliances are subject to recalls. Areas and components behind and obscured by appliances are inaccessible and excluded from this inspection.
Permanently installed kitchen appliances present during inspection: Range, Oven, Dishwasher, Refrigerator, Under-sink food disposal, Microwave oven
Condition of counters: Appeared serviceable
Range, cooktop, oven type: Natural gas
Type of ventilation: Hood or built into microwave over range or cooktop
47) Gaps, no caulk, or substandard caulking were found between countertops and backsplashes. Water may penetrate these areas and cause damage. Recommend that a qualified person repair as necessary. For example, by installing caulk.
Photo
Photo 47-1 Kitchen countertop to backsplash grout cracking, #1.
Photo
Photo 47-2 Kitchen countertop to backsplash grout cracking, #2.
48) Recommend cleaning and sealing the grout at countertops now and in the future as necessary to prevent staining and to improve waterproofing.
49) In the kitchen it was observed in one or more locations that there were chips in the tile of the backsplash. This is a mostly cosmetic issue and would be up to the owner to decide if any action is necessary.
Photo
Photo 49-1 Kitchen backsplash near refrigerator.
Bathrooms, Laundry and Sinks
Table of contents
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Location #A: Master bath, west
Location #B: Full bath, second floor, east
240 volt receptacle for laundry equipment present: Yes
50) The clothes dryer exhaust duct was very long an/or had multiple bends. This can reduce the air flow through the duct, resulting in overheating, reduced efficiency and/or difficulty in cleaning the duct. Maximum lengths for such ducts vary widely by manufacturer and model of clothes dryer (15-90 feet with no bends). If unable to determine the maximum length/bends configuration for this clothes dryer, then general guidelines limit exhaust ducts to 25 feet, or less when bends are present (2.5 feet for each 45-degree bend and 5 feet for each 90-degree bend). Recommend that a qualified contractor evaluate to determine if the duct complies with the clothes dryer manufacturer's specifications for an exhaust duct, and repair if necessary. For more information, visit:
https://www.reporthost.com/?DRYERLNG
51) The clothes dryer exhaust duct was kinked, crushed or damaged. Air flow will be restricted as a result and the clothes dryer may overheat. This is a safety hazard due to the risk of fire. Recommend that a qualified person replace or repair the duct as necessary. For more information, visit:
https://www.reporthost.com/?DRYER
Photo
Photo 51-1 Dryer duct.
52) Tile and/or grout in the bathtub surround at location(s) #B was deteriorated (e.g. loose or cracked tiles, missing grout) or substandard. Water can damage the wall structure as a result. Recommend that a qualified contractor repair as necessary.
Photo
Photo 52-1 Tub to tile grout line cracked.
Photo
Photo 52-2 Tub tile grout cracked.
53) Tile, caulk and/or grout in the shower enclosure at location(s) #A were deteriorated (e.g. loose or cracked tiles, missing grout) or substandard. Water may leak through gaps and damage the wall or floor structure as a result. Recommend that a qualified contractor repair as necessary. Note that the condition of the structure behind and below the shower enclosure is unknown due to it being concealed.
Photo
Photo 53-1 Master shower floor to shower base grout cracked.
54) Rubber water supply hoses were installed at the clothes washer. These hoses are prone to bursting when deteriorated, which can result in flooding and significant water damage. Recommend upgrading to braided, stainless steel hoses.
Photo
Photo 54-1 Washing machine hoses.
Interior, Doors and Windows
Table of contents
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; cosmetic deficiencies such as nail-pops, scuff marks, dents, dings, blemishes or issues due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window, drawer, cabinet door or closet door operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Carpeting and flooring, when installed over concrete slabs, may conceal moisture. If dampness wicks through a slab and is hidden by floor coverings that moisture can result in unhygienic conditions, odors or problems that will only be discovered when/if the flooring is removed. Determining the cause and/or source of odors is not within the scope of this inspection.
Exterior door material: Wood
Type(s) of windows: Vinyl
Wall type or covering: Drywall
Ceiling type or covering: Drywall
55) Guardrails at one or more locations with horizontal balusters pose a childing climbing hazard. Recommend that a qualified person repair guardrails as necessary.
Photo
Photo 55-1 Front patio railing.
56) Trim or jambs around one or more exterior doors was substandard. Recommend that a qualified person repair, replace or install as necessary.
Photo
Photo 56-1 Front door, bottom left corner.

This inspection report adheres to the Home Inspection Standards of Practice (January 2018) from InterNACHI.

If you’re reading this report but did not hire me, Faithful Home Inspections LLC, to perform the original inspection, please note that it is likely that conditions related to the home have probably changed, even if the report is fairly recent. You should not rely on an outdated inspection report. Minor problems noted may have become worse, recent events may have created new issues, and items may even have been corrected and improved. Don’t rely on old information about one of the biggest purchases you’ll ever make. Remember that the cost of a home inspection is insignificant compared to the value of the home. Protect your family and your investment, and please call me directly at 303.919.1782 to discuss the report you’re reading for this property so that we can arrange for a re-inspection. Thank you!