Property Inspection Report
Client(s):
Ryan Matson, Anna Karp
Property address:
7490 Cedar Ct Goodrich MI 48438-8754
Inspection date:
Thursday, March 12, 2020
This report published on Tuesday, March 17, 2020 2:52:25 AM EDT
This report is the exclusive property of Home Inspector John, LLC and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited. This inspection is a limited visual report of the general condition of the home and its major components at the time of the inspection. Please review the pre-inspection agreement that you have been provided for an explanation of the scope and restrictions of this report.
How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
Safety
Poses a risk of injury or death
Repair/Replace
Recommend repairing or replacing
Repair/Maintain
Recommend repair and/or maintenance
Minor Defect
Correction likely involves only a minor expense
Maintain
Recommend ongoing maintenance
Evaluate
Recommend evaluation by a specialist
Monitor
Recommend monitoring in the future
Serviceable
Item or component is in serviceable condition
Comment
For your information
Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp
Client present for discussion at end of inspection: Yes
Inspector: John Rice, CPI
Weather conditions during inspection: Dry (no rain)
Temperature during inspection: Cold
Ground condition: Dry
Recent weather: Dry (no rain)
Overnight temperature: Cold
Inspection fee: $250
Payment method: Cash
Type of building: Single family
Buildings inspected: One house
Number of residential units inspected: 1
Age of main building: 2004
Source for main building age: Municipal records or property listing
Front of building faces: East
Main entrance faces: East
Occupied: Yes, Furniture or stored items were present
Source for additions and modifications: Municipal records
1) Some areas and items at this property were obscured by furniture, stored items and/or debris. This often includes but is not limited to walls, floors, windows, inside and under cabinets, under sinks, on counter tops, in closets, behind window coverings, under rugs or carpets, and under or behind furniture. Areas around the exterior, under the structure, in the garage and in the attic may also be obscured by stored items. The inspector in general does not move personal belongings, furnishings, carpets or appliances. When furnishings, stored items or debris are present, all areas or items that are obscured, concealed or not readily accessible are excluded from the inspection. The client should be aware that when furnishings, stored items or debris are eventually moved, damage or problems that were not noted during the inspection may be found.
Photo 1-1 Personal items located inside the garage. Photo 1-2 Food items in cooking products stored inside pantry cabinet.
Photo 1-3 Items stored inside kitchen cabinets. Photo 1-4 All closets had personal items present.
Photo 1-5 Photo 1-6
Photo 1-7 Photo 1-8
Photo 1-9 Personal items stored in basement underneath stairwell. Photo 1-10 Personal items stored in mechanical area of basement.
Limitations: Unless specifically included in the inspection, the following items and any related equipment, controls, electric systems and/or plumbing systems are excluded from this inspection: detached buildings or structures; fences and gates; retaining walls; underground drainage systems, catch basins or concealed sump pumps; swimming pools and related safety equipment, spas, hot tubs or saunas; whether deck, balcony and/or stair membranes are watertight; trees, landscaping, properties of soil, soil stability, erosion and erosion control; ponds, water features, irrigation or yard sprinkler systems; sport courts, playground, recreation or leisure equipment; areas below the exterior structures with less than 3 feet of vertical clearance; invisible fencing; sea walls, docks and boathouses; retractable awnings. Any comments made regarding these items are as a courtesy only.
Site profile: Moderate slope
Condition of driveway: Appeared serviceable
Driveway material: Poured in place concrete
Condition of sidewalks and/or patios: Required repairs, replacement and/or evaluation (see comments below)
Sidewalk material: Poured in place concrete
Condition of deck, patio and/or porch covers: Appeared serviceable
Deck, patio, porch cover material and type: Open
Condition of decks, porches and/or balconies: Appeared serviceable, Required repairs, replacement and/or evaluation (see comments below)
Deck, porch and/or balcony material: Wood
Condition of stairs, handrails and guardrails: Required repairs, replacement and/or evaluation (see comments below)
Exterior stair material: Wood
2) The risers for stairs at one or more locations varied in height and pose a fall or trip hazard. Risers within the same flight of stairs should vary by no more than 3/8 inch. At a minimum, be aware of this hazard, especially when guests who are not familiar with the stairs are present. Recommend that a qualified contractor repair per standard building practices.
Photo 2-1 Deck steps rises are inconsistent. This can cause a possible trip hazard. Photo 2-2
Photo 2-3
3) Handrails at one or more flights of stairs were missing. This is a potential fall hazard. Handrails should be installed at stairs with four or more risers or where stairs are greater than 30 inches high. Recommend that a qualified contractor install handrails where missing and per standard building practices.
Photo 3-1 A handrail is required by building code for safety at a deck of this height. Recommend having a qualified contractor install one as needed per local building code.
4) Cracks, holes, settlement, heaving and/or deterioration resulting in trip hazards were found in the sidewalks or patios. For safety reasons, recommend that a qualified contractor repair as necessary to eliminate trip hazards.
Photo 4-1 Photo 4-2
Photo 4-3 Photo 4-4
Photo 4-5 Photo 4-6 Two trip hazards are present in front porch walk. Recommend having a qualified professional repair or replace as necessary.
Photo 4-7
5) Guardrails at one or more locations with drop-offs higher than 30 inches were loose and/or wobbly, and pose a fall hazard. Recommend that a qualified person repair guardrails as necessary.
Photo 5-1 Photo 5-2
6) Minor deterioration (e.g. cracks, holes, settlement, heaving) was found in the driveway, but no trip hazards were found. The client may wish to have repairs made for cosmetic reasons.
Photo 6-1
7) Some deck covers were obscured by carpet and couldn't be fully evaluated.
Limitations: The inspector performs a visual inspection of accessible components or systems at the exterior. Items excluded from this inspection include below-grade foundation walls and footings; foundations, exterior surfaces or components obscured by vegetation, stored items or debris; wall structures obscured by coverings such as siding or trim. Some items such as siding, trim, soffits, vents and windows are often high off the ground, and may be viewed using binoculars from the ground or from a ladder. This may limit a full evaluation. Regarding foundations, some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determine the adequacy of seismic reinforcement.
Condition of wall exterior covering: Appeared serviceable
Apparent wall structure: Wood frame
Wall covering: Vinyl, Brick veneer
Condition of foundation and footings: Appeared serviceable
Apparent foundation type: Finished basement
Foundation/stem wall material: Poured in place concrete
Footing material (under foundation stem wall): Not determined (inaccessible or obscured)
8) The electric meter was observed to be lower than originally installed. This can be due to the fact of the underground service feed or socket cabinet was installed incorrectly. Recommend having a qualified electrical contractor repair or replace and the weather seal as necessary.
Photo 8-1 The electric meter cabinet is lower than originally installed and now there is a chance for water to enter the home and/or the meter cabinet itself. Recommend hiring qualified electrical contractor to repair or replace and weather seal the exterior as needed. Photo 8-2
9) Several wasp nests were observed on the main dwelling in the peaks of soffitts and inside vents. Recommend having a qualified professional remove nests as necessary.
Photo 9-1 Wasp nest A in gable Photo 9-2 Wasp nest A
Photo 9-3 Wasp nest B in vent Photo 9-4 Wasp nest B
Photo 9-5 Wasp nest C in vent Photo 9-6 Wasp nest C
Photo 9-7 Wasp nest D in vent Photo 9-8 Wasp nest D
10) Some sections of siding and/or trim were substandard. Recommend that a qualified person repair, replace or install siding or trim as necessary.
Photo 10-1 Photo 10-2
11) A vent and duct if unknown use was observed at rear of house. Recommend having qualified professional seal off vent and duct from the interior and weather seal the exterior
Photo 11-1 Vent of unknown use present in rear of home. Photo 11-2 Duct leading to vent is not connected to anything in the interior. Recommend sealing duct.
Photo 11-3 Unknown vent is not properly weather sealed. Recommend sealing and eliminating.
12) One or more minor cracks (1/8 inch or less) were found in the foundation. These didn't appear to be a structural concern, but recommend sealing them to prevent water infiltration and monitor them in the future. Numerous products exist to seal such cracks including hydraulic cement, non-shrinking grout, resilient caulks and epoxy sealants.
13) Vegetation such as trees, shrubs and/or vines was in contact with or close to the building exterior. Vegetation can serve as a pathway for wood-destroying insects and can retain moisture against the exterior after it rains. This is a conducive condition for wood-destroying organisms. Recommend pruning, moving or removing vegetation as necessary to maintain at least 6 inches of space between it and the building exterior. A 1-foot clearance is better.
Photo 13-1 Photo 13-2
Photo 13-3 Photo 13-4
14) Deck structure and undercarriage were observed to be in serviceable condition. Some paint was observed on deck boards to be peeling. Would recommend permanently removing the rug from the deck surface to prevent future problems and repairing/painting deck surface as needed.
A rodent or other vermin's nest was observed under the deck. Recommend further evaluation by a qualified exterminator.
Photo 14-1 Deck undercarriage was observed to be in serviceable condition. A possible rodents nest is visible under deck, recommend having a qualified professional exterminator further evaluate and proceed as necessary. Photo 14-2
Photo 14-3 Photo 14-4 Peeling paint was observed at this location on deck surface.
15) A rodent trap was found on the property. Recommend speaking with owner about the necessity of further traps and monitoring.
Photo 15-1 Location of rodent trap
16) Various elevations of main dwelling and perimeter
Photo 16-1 East elevation of home. Photo 16-2 North elevation of home.
Photo 16-3 Northwest elevation of home. Photo 16-4 Deck and Patio.
Photo 16-5 West elevation of home. Photo 16-6 Southwest elevation of home.
Photo 16-7 South elevation of home. Photo 16-8 Pond area.
Photo 16-9 View of rear yard 1. Photo 16-10 View of rear yard 2.
Photo 16-11 View of rear yard 3. Photo 16-12 View of rear yard 4.
17) All exterior GFCI outlets were tested and functioning.
Photo 17-1 Photo 17-2
Photo 17-3
18) The mailbox is in a state of disrepair and could interfere with mail delivery. Recommend having qualified person repair or replace as necessary.
Photo 18-1 The mailbox is not level and plumb and is falling towards the street.
Limitations: Structural components such as joists and beams, and other components such as piping, wiring and/or ducting that are obscured by under-floor insulation are also excluded from this inspection. Note that the inspector does not determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.
The inspector does not guarantee or warrant that water will not accumulate in the basement in the future. Access to the basement during all seasons and during prolonged periods of all types of weather conditions (e.g. heavy rain, melting snow) would be needed to do so. The inspector does not determine the adequacy of basement floor or stairwell drains, or determine if such drains are clear or clogged.
Note that all basement areas should be checked periodically for water intrusion, plumbing leaks and pest activity.
Pier or support post material: Concrete
Beam material: Steel
Floor structure: Solid wood joists
Condition of insulation underneath floor above: Not determined (inaccessible or obscured)
Insulation material underneath floor above: Not determined (inaccessible or obscured)
Bond insulation present:: Yes
19) Many areas were not evaluated due to lack of access from stored items and/or /finished living space. These areas are excluded from the inspection.
Photo 19-1 The basement was in a finished condition. Due to the lack of access from this condition, this can hide many deficiencies including cracked foundation walls, mold growth, termites, etc. Although the inspector performed a complete and thorough inspection of this area to the best ability based on the current finished condition, the inspector believes there to be no deficiencies present other than the items listed within this section of the report. However, hidden items may be present behind finished walls and ceilings and without the presence of underlying identifiers to suggest problems, the inspector must exclude finished areas and areas where stored items are present from this report and recommend continued monitoring of this and other such areas. Photo 19-2 The craftsmanship in the basement was observed to be of excellent quality.
20) The continued use of a dehumidifier is recommended. Keep the unit running constantly with a minimum setting of at least 50% relative humidity. This will help prevent "musty" smells and the formation of mold.
Photo 20-1 A self draining, continuous use type unit is recommended.
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; solar roofing components. Any comments made regarding these items are made as a courtesy only. Note that the inspector does not provide an estimate of remaining life on the roof surface material, nor guarantee that leaks have not occurred in the roof surface, skylights or roof penetrations in the past. Regarding roof leaks, only active leaks, visible evidence of possible sources of leaks, and evidence of past leaks observed during the inspection are reported on as part of this inspection. The inspector does not guarantee or warrant that leaks will not occur in the future. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high wind and rain, melting snow) would be needed to do so. Regarding the roof drainage system, unless the inspection was conducted during and after prolonged periods of heavy rain, the inspector was unable to determine if gutters, downspouts and extensions performed adequately or were leak-free.
Age of roof surface(s): 2004
Roof inspection method: Traversed
Condition of roof surface material: Appeared serviceable
Roof surface material: Asphalt or fiberglass composition shingles
Roof type: Gable
Apparent number of layers of roof surface material: One
Condition of exposed flashings: Appeared serviceable
Condition of gutters, downspouts and extensions: Appeared serviceable, Required repair, replacement and/or evaluation (see comments below)
Gutter and downspout material: Metal
Gutter and downspout installation: Full
21) Extensions such as splash blocks or drain pipes for one or more downspouts were missing. Water can accumulate around the building foundation or inside crawl spaces or basements as a result. Recommend that a qualified person install, replace or repair extensions as necessary so rainwater drains away from the structure.
Two downspouts were missing extensions at the rear of the home.
Photo 21-1 Inspector recommends at least 36 inches of extension to keep water from collecting at the foundation. Photo 21-2
22) The roof was observed to be in serviceable condition and appears to be the original roof surface from the date the home was manufactured in 2004. As such, the roof has a life span estimated from the shingle manufacturer of 25 years estimating 9-10 more years of serviceable use.
(This is not a guarantee, but merely a guide for budgeting your next replacement roof.)
The gutter system was observed to be in serviceable condition. The gutters are clean and in good overall condition.
Photo 22-1 No deficiencies were observed in the roof. The roof condition is consistent with a surface of this age. Photo 22-2
Photo 22-3 The gutter system is in good repair and does not require cleaning at this time. Photo 22-4
Limitations: The inspector does not determine the adequacy of firewall ratings. Requirements for ventilation in garages vary between municipalities.
Type: Attached
Condition of garage: Appeared serviceable
Type of door between garage and house: Metal
Type of garage vehicle door: Sectional
Number of vehicle doors: 1
Condition of automatic opener(s): Appeared serviceable
Mechanical auto-reverse operable (reverses when meeting reasonable resistance during closing): Yes
Condition of garage floor: Appeared serviceable
Condition of garage interior: Appeared serviceable
Garage ventilation: None
23) The step(s) installed below the door between the garage and the house were substandard. This is a fall or trip hazard. A qualified person should repair as necessary.
The steps installed are not to proper rise heights. Recommend replacement as needed.
Photo 23-1
24) Garage outlets were GFCI protected as required by code.
Photo 24-1
25) Two keyless light fixtures in the garage ceiling were not functioning at the time of inspection. This could be something as simple as a bad bulb. Recommend further evaluation.
Photo 25-1
26) Garage door opener functioned as required and appears in serviceable conditon.
Photo 26-1
27) Some items were present in the garage at the time of inspection.
Limitations: The following items are not included in this inspection: generator systems, transfer switches, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low-voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, if this system has an adequate capacity for the client's specific or anticipated needs, or if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, and does not install or change light bulbs. The inspector does not evaluate every wall switch or receptacle, but instead tests a representative number of them per various standards of practice. When furnishings, stored items or child-protective caps are present some receptacles are usually inaccessible and are not tested; these are excluded from this inspection. Receptacles that are not of standard 110 volt configuration, including 240-volt dryer receptacles, are not tested and are excluded. The functionality of, power source for and placement of smoke and carbon monoxide detectors is not determined as part of this inspection. Upon taking occupancy, proper operating and placement of smoke and carbon monoxide detectors should be verified and batteries should be changed. These devices have a limited lifespan and should be replaced every 10 years. The inspector attempts to locate and evaluate all main and sub-panels. However, panels are often concealed. If panels are found after the inspection, a qualified electrician should evaluate and repair if necessary. The inspector attempts to determine the overall electrical service size, but such estimates are not guaranteed because the overall capacity may be diminished by lesser-rated components in the system. Any repairs recommended should be made by a licensed electrician.
Electric service condition: Appeared serviceable
Primary service type: Underground
Number of service conductors: 2
Service voltage (volts): 120-240
Estimated service amperage: 200
Primary service overload protection type: Circuit breakers
Service entrance conductor material: Stranded aluminum
Main disconnect rating (amps): 100
System ground: Not determined, not readily apparent
Condition of main service panel: Appeared serviceable
Location of main service panel #A: Basement
Location of main disconnect: Top bank of breakers in main service panel (split bus)
Circuit breakers that were in the "off" position: none
Carbon monoxide alarms installed: No, recommend install
Smoke alarm power source(s): Hard wired
28) One or more smoke alarms were missing, damaged, or missing components. Smoke alarms should be replaced as necessary. For more information, visit: http://www.cpsc.gov/cpscpub/pubs/559.pdf
Smoke alarm in main floor bedroom did not function properly when tested.
Smoke alarm in upstairs master bedroom was missing.
Photo 28-1 Smoke alarm in first floor bedroom is not functioning properly. Photo 28-2 Smoke alarm missing from master bedroom.
Photo 28-3 Smoke alarm missing from master bedroom
29) The legend for circuit breakers or fuses in panel(s) #A was missing, incomplete, illegible or confusing. This is a potential shock or fire hazard in the event of an emergency when power needs to be turned off. Recommend correcting the legend so it's accurate, complete and legible. Evaluation by a qualified electrician may be necessary.
30) Based on the age of this structure and the appearance of existing smoke alarms, the alarms may have been installed more than 10 years ago. According to National Fire Protection Association, aging smoke alarms don't operate as efficiently and often are the source for nuisance alarms. Older smoke alarms are estimated to have a 30% probability of failure within the first 10 years. Newer smoke alarms do better, but should be replaced after 10 years. Unless you know that the smoke alarms are new, replacing them when moving into a new residence is also recommended by NFPA. For more information, visit: http://www.google.com/search?q=old+smoke+alarms
Photo 30-1 Photo 30-2
31) No carbon monoxide alarms were visible. This is a potential safety hazard. Some states and/or municipalities require CO alarms to be installed for new construction and/or for homes being sold. Recommend installing approved CO alarms outside of each separate sleeping area in the immediate vicinity of the bedrooms on each level and in accordance with the manufacturer's recommendations. For more information, visit: http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
32) The electric service to this property appeared to be rated at substantially less than 200 amps and may be inadequate. Depending on the client's needs, recommend consulting with a qualified electrician about upgrading to a 200 amp service. Note that the electric service's rating is based on the lowest rating for the meter base, the service conductors, the main service panel and the main disconnect switch. One or more of these components may need replacing to upgrade.
As discussed at the time of the inspection, the current panel is full and cannot accept any more circuits. Should a new circuit or panel be needed, recommend upgrading to a 200 amp service panel. Please note that current panel should provide adequate service for electrical needs as currently in use.
Photo 32-1 Photo 32-2
Photo 32-3 Photo 32-4 Main electric shutoff
Photo 32-5 Panel is properly wired and appears to be in serviceable condition. Photo 32-6
33) All outlets and GFCIs were inspected in the home and observed to be in serviceable condition.
Limitations: The following items are not included in this inspection: private/shared wells and related equipment; private sewage disposal systems; hot tubs or spas; main, side and lateral sewer lines; gray water systems; pressure boosting systems; trap primers; incinerating or composting toilets; fire suppression systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determine the existence or condition of underground or above-ground fuel tanks.
Condition of service and main line: Appeared serviceable
Location of main water meter: Not applicable (private or shared well)
Location of main water shut-off: Basement, In utility room
Water service: Private well
Service pipe material: Copper
Condition of supply lines: Appeared serviceable
Supply pipe material: Copper
Condition of drain pipes: Appeared serviceable
Drain pipe material: Plastic
Condition of waste lines: Appeared serviceable
Waste pipe material: Galvanized steel
Location(s) of plumbing clean-outs: Basement
Vent pipe condition: Appeared serviceable
Vent pipe material: Plastic
Sump pump installed: Yes
Condition of sump pump: Appeared serviceable
Sewage ejector pump installed: No
Condition of fuel system: Appeared serviceable
Visible fuel storage systems: None visible
Location of main fuel shut-off valve: At gas meter
34) A 40 gallon gas power vent hot water heater is present. A power vent water heater uses a blower or fan to exhaust gases by pushing them through vent pipes that are horizontal. The primary advantage of a power vent is that the water heater can be located in any area and does not require a vertical vent or chimney.
The power supply outlet plate cover for the hot water heater is loose and should be repaired or replaced as necessary to prevent chance of fire or electric shock.
The hot water heater was observed to be in serviceable condition.
Photo 34-1 Electrical outlet with loose cover plate. Photo 34-2 Electrical outlet needs new cover plate.
Photo 34-3 Photo 34-4
Photo 34-5 Photo 34-6
35) Location of main gas shutoff is at exterior meter.
Photo 35-1 Location of main gas shut off
36) Low flow was found at one or more sinks when multiple fixtures were operated at the same time. Water supply pipes may be clogged or corroded, filters may be clogged or need new cartridges, or fixtures may be clogged. Recommend that a qualified plumber evaluate and repair as necessary.
The kitchen faucet had low flow without the multiple fixture test. Recommend changing faucet, and if necessary, faucet supply lines and shut off valves to restore full water flow.
Photo 36-1
37) Based on visible equipment or information provided to the inspector, the water supply to this property appeared to be from a private well. Private well water supplies are specialty systems and are excluded from this inspection. Comments in this report related to this system are made as a courtesy only and are not meant to be a substitute for a full evaluation by a qualified specialist. The inspector does not test private well water for contamination or pollutants, determine if the supply and/or flow are adequate, or provide an estimate for remaining life of well pumps, pressure tanks or equipment. Only visible and accessible components are evaluated. Recommend the following:
That a qualified well contractor fully evaluate the well, including a pump/flow test
That the well water be tested per the client's concerns (coliforms, pH, contaminants, etc.)
Research the well's history (how/when constructed, how/when maintained or repaired, past performance, past health issues)
Document the current well capacity and water quality for future reference
38) A water softener system was installed on the premises. These are specialty systems and are excluded from this inspection. Comments in this report related to this system are made as a courtesy only and are not meant to be a substitute for a full evaluation by a qualified specialist. Water softeners typically work by removing unwanted minerals (e.g. calcium, magnesium) from the water supply. They prevent build-up of scale inside water supply pipes, improve lathering while washing, and prevent spots on dishes. Recommend consulting with the property owner about this system to determine its condition, required maintenance, age, expected remaining life, etc. For more information, visit: http://www.google.com/search?q=water+softeners http://www.google.com/search?q=hard+water
Photo 38-1 Photo 38-2
39) A sump pump was installed in the basement. These are specialty systems and only a limited evaluation was performed as part of this inspection. The inspector does not determine the adequacy of sump pumps and their associated drainage systems. The presence of a sump pump may indicate that water routinely accumulates below or inside the structure. Recommend asking the property owner how often the sump pump operates and for how long at different times of the year. The client should be aware that the service life of most sump pumps is 5-7 years, and that the pump may need replacing soon depending on its age and how often it operates.
Photo 39-1 Photo 39-2
40) No battery backup system was found for the sump pump. If the power goes out during heavy rains, the sump pump won't be able to eliminate accumulated water. Consider installing a battery backup system for the sump pump.
41) All bath toilets, faucets and showers were observed to be in serviceable condition. The bar sink was observed to be in serviceable condition.
Limitations: Evaluation of and determining the adequacy or completeness of the following items are not included in this inspection: water recirculation pumps; solar water heating systems; Energy Smart or energy saver controls; catch pan drains. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit or a shut-off valve to be operated.
Condition of water heater: Appeared serviceable
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 40
Temperature-pressure relief valve installed: Yes
Manufacturer: American
Model number: PVG62-40T50-NV3
Serial number: 0450120532
Location of water heater: Basement
Hot water temperature tested: No
Condition of burners: Appeared serviceable
Condition of venting system: Appeared serviceable
Condition of combustion air supply: Appeared serviceable
42) The estimated useful life for most water heaters is 8-12 years. This water heater appeared to be beyond this age and/or its useful lifespan and may need replacing at any time. Recommend budgeting for a replacement in the near future, or considering replacement now before any leaks occur. The client should be aware that significant flooding can occur if the water heater fails. If not replaced now, consider having a qualified person install a catch pan and drain or a water alarm to help prevent damage if water does leak.
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood-fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating or cooling system components, does not determine if heating or cooling systems are appropriately sized, does not test coolant pressure, or perform any evaluations that require a pilot light to be lit, a shut-off valve to be operated, a circuit breaker to be turned "on" or a serviceman's or oil emergency switch to be operated. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future. Where buildings contain furnishings or stored items, the inspector may not be able to verify that a heat source is present in all "liveable" rooms (e.g. bedrooms, kitchens and living/dining rooms).
General heating system type(s): Forced air
General heating distribution type(s): Ducts and registers
Last service date of primary heat source: 4/11/2013
Source for last service date of primary heat source: Label
Condition of forced air heating/(cooling) system: Appeared serviceable
Forced air heating system fuel type: Electric
Estimated age of forced air furnace: 5/2005
Forced air heating system manufacturer: Trane
Forced air furnace model #: TUX080C942D3
Forced air furnace serial number: 5204RUW7G
Location of forced air furnace: Mechanical room, Basement
Forced air system capacity in BTUs or kilowatts: 80,000 BTUs
Condition of furnace filters: Required repair and/or evaluation (see comments below)
Location for forced air filter(s): At base of air handler
Condition of forced air ducts and registers: Appeared serviceable
Condition of venting system: Appeared serviceable
Condition of combustion air supply: Appeared serviceable
Condition of cooling system and/or heat pump: Not determined
Cooling system and/or heat pump fuel type: Electric
Location: exterior northwest
Type: Packaged unit
Estimated age: 2012
Approximate tonnage: 2
Manufacturer: Rheem
Condition of controls: Not determined (system inoperable)
43) Significant amounts of debris, dirt and/or dust were visible in one or more sections of supply and/or return air ducts for the heating or cooling system. This can be a health hazard, especially for those with allergies or respiratory problems. The Environmental Protection Agency (EPA) recommends considering having ducts professionally cleaned when "ducts are clogged with excessive amounts of dust and debris and/or particles are actually released into the home from your supply registers." At a minimum, the visible debris should be thoroughly cleaned. Recommend that a qualified contractor clean the ducts. For more information on duct cleaning in relation to indoor air quality, visit: http://www.epa.gov/iaq/pubs/airduct.html
Photo 43-1 Dust and debris is visible inside vent
44) The last service date of the gas or oil-fired forced air furnace appeared to be more than 1 year ago, or the inspector was unable to determine the last service date. Ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than 1 year ago, recommend that a qualified HVAC contractor inspect, clean, and service this system, and make repairs if necessary. For safety reasons, and because this system is fueled by gas or oil, this servicing should be performed annually in the future. Any needed repairs noted in this report should be brought to the attention of the HVAC contractor when it's serviced. For more information visit: http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
45) An improperly sized furnace filter was installed in the furnace. It was visibly too large to fit. The proper size is 16x20x1.
Photo 45-1 This filter is the wrong size. Correct size is 16x20x1.
46) The last service date of the forced air heating/cooling system appeared to be more than 1 year ago, or the inspector was unable to determine the last service date. Ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than 1 year ago, recommend that a qualified HVAC contractor service this system and make repairs if necessary. Because this system has a compressor and refrigerant system, this servicing should be performed annually in the future. Any needed repairs noted in this report should be brought to the attention of the contractor when it's serviced.
47) The gas or oil-fired forced air furnace appeared to have been serviced within the last year based on information provided to the inspector or labeling on the equipment. If this is true, then routine servicing is not needed at this point. However a qualified HVAC contractor should inspect, clean, and service this system, and make repairs if necessary annually in the future. For more information visit: http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
Photo 47-1
48) Thermostat was observed to be in serviceable condition.
Photo 48-1 This is a good quality programmable thermostat.
49) The estimated useful life for most forced air furnaces is 15-20 years. This furnace appeared to be at this age and/or its useful lifespan and may need replacing or significant repairs at any time. Recommend budgeting for a replacement in the near future.
Although near the end of service life expectancy, furnace appears to be in good serviceable condition.
Photo 49-1 Photo 49-2
Photo 49-3 Photo 49-4 This is the a-coil information sticker for the a/c unit.
Photo 49-5 Photo 49-6
Photo 49-7 Furnace was manufactured 5/2005. Photo 49-8
Photo 49-9 Furnace has a nice blue flame with little to no orange meaning the heat exchanger doesn't appear to be cracked or leaking.
50) The outdoor air temperature was below 65 degrees Fahrenheit during the inspection. Air conditioning systems can be damaged if operated during such low temperatures. Because of this, the inspector was unable to operate and fully evaluate the cooling system.
Photo 50-1 A/C unit was unable to be operated at temps below 65 F. This is excluded from the inspection. Photo 50-2 A/C unit was installed in 2013
Photo 50-3 A/C service disconnect. Turn fuse to off during months when the temp is below 65 F to help prevent accidental damage to the unit or system. Photo 50-4
Limitations: The following items are not included in this inspection: household appliances such as stoves, ovens, cook tops, ranges, warming ovens, griddles, broilers, dishwashers, trash compactors, refrigerators, freezers, ice makers, hot water dispensers and water filters; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances. The inspector does not note appliance manufacturers, models or serial numbers and does not determine if appliances are subject to recalls. Areas and components behind and obscured by appliances are inaccessible and excluded from this inspection.
Condition of sinks and related plumbing: Appeared serviceable
Condition of under-sink food disposal: Appeared serviceable
Condition of dishwasher: Not determined
Condition of range, cooktop: Not determined
Condition of refrigerator: Not determined
51) The kitchen appeared to be in good overall condition.
Photo 51-1 general photos of kitchen Photo 51-2
Photo 51-3
52) The testing of the appliances is beyond the scope of this inspection. The inspector does offer RecallChek to verify any recalls as a courtesy to the client(s). Any errors or omissions in results is not the responsibility of the inspector.
Photo 52-1 Photo 52-2
Photo 52-3 Photo 52-4
Photo 52-5 Photo 52-6
Photo 52-7 Photo 52-8
53) The presence of stored items under the sink limits the inspection in this area as the inspector is not permitted to move personal items.
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Location #A: Powder room, first floor
Location #B: Full bath, first floor
Location #C: Master bath, second floor
Location #D: Bar sink
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of flooring: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of toilets: Appeared serviceable
Condition of bathtubs and related plumbing: Appeared serviceable
Condition of ventilation systems: Appeared serviceable
Bathroom ventilation type: Spot fans
Gas supply for laundry equipment present: Not determined
240 volt receptacle for laundry equipment present: Not determined
54) No access or only limited access was available to the back of the clothes washer and dryer, and to utility hook-ups located behind the appliances. The inspector normally attempts to determine the presence of a gas vs. electric power supply, the configuration of the stand pipe, whether the dryer exhaust duct is serviceable, etc. Because of the lack of access, the inspector was unable to fully evaluate and/or describe the hook-ups and appliances.
Photo 54-1 The presence of personal items and tight spacing limited the inspection of the laundry hookups. Photo 54-2
Photo 54-3
55) The areas below sink(s) at location(s) #A, B, C and D were obscured by stored items and couldn't be fully evaluated.
Photo 55-1 Powder Room A Photo 55-2 First Floor Bath B
Photo 55-3 Master Bath C Photo 55-4 Bar sink D
56) All baths, laundry room, and bar area was observed to be in serviceable condition.
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; cosmetic deficiencies such as nail-pops, scuff marks, dents, dings, blemishes or issues due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window, drawer, cabinet door or closet door operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Determining the cause and/or source of odors is not within the scope of this inspection.
Condition of exterior entry doors: Appeared serviceable
Exterior door material: Metal
Condition of interior doors: Appeared serviceable
Condition of windows and skylights: Appeared serviceable
Type(s) of windows: Vinyl
Condition of walls and ceilings: Appeared serviceable
Wall type or covering: Drywall
Ceiling type or covering: Drywall
Condition of flooring: Appeared serviceable
Flooring type or covering: Carpet, Vinyl, linoleum or marmoleum, Laminate
Condition of stairs, handrails and guardrails: Required repairs, replacement and/or evaluation (see comments below)
57) Handrails at one or more flights of stairs were missing. This is a potential fall hazard. Handrails should be installed at stairs with four or more risers or where stairs are greater than 30 inches high. Recommend that a qualified contractor install handrails where missing and per standard building practices.
Photo 57-1 A graspable handrail is required at this location. It can be installed on either wall. Photo 57-2
Photo 57-3 Length of missing handrail 11'4"
58) Lock mechanisms on one or more windows were inoperable. This can pose a security risk. Recommend that a qualified person repair as necessary.
59) One or more window screens were damaged or deteriorated. These window(s) may not provide ventilation during months when insects are active. Recommend replacing window screens as necessary.
Master bedroom window and door wall screens need replacement.
Photo 59-1 Master bedroom window screen is damaged. Photo 59-2
Photo 59-3 Doorwall screen damaged Photo 59-4
60) One or more bifold doors were off their track(s) or difficult to operate. Recommend that a qualified person repair as necessary.
Master bedroom bifold closet door is difficult to open.
Photo 60-1
61) Minor peeling of paint was observed in upstairs bedroom window opening.
Photo 61-1
62) Some exterior doors didn't have a screen door.
Front entry door does not have a storm/screen door. Recommend installing a door to aid in heating/cooling of the home.
Photo 62-1 There is no storm door present at the front entry door.
63) General photos of the interior of the home.
Photo 63-1 Photo 63-2
Photo 63-3 Photo 63-4
Photo 63-5 Photo 63-6
Photo 63-7 Photo 63-8
Photo 63-9 Photo 63-10
Photo 63-11 Photo 63-12
64) Window information is located inside the jambs when sashes are moved.
Limitations: Private well water supplies are specialty systems and are beyond the scope of the standards of practice for home inspections. Comments in this report related to a private well are made as a courtesy only and are not meant to be a substitute for a full evaluation by a qualified well specialist. The inspector does not test private well water for contamination or pollutants, determine if the supply and/or flow are adequate, or provide an estimate for remaining life of well pumps, pressure tanks or equipment. Only visible components are evaluated.
Condition of private water supply: Appeared serviceable
Type of well: Not determined
Location of well: not determined
Source for information about the well: Municipal records
Condition of pump: Not determined
Type of pump: Not determined
Condition of well equipment: Not determined
Location of well equipment: Basement, Mechanical room
Condition of pressure tank: Not determined
65) Because this is a specialty system, recommend the following:
That a qualified well contractor fully evaluate the well, including a pump/flow test
That the well water be tested per the client's concerns (e.g. coliforms, pH, contaminants) by a qualified lab
That the client research the well's history (e.g. how/when constructed, how/when maintained or repaired, past performance, past health issues)
That that the client document the current well capacity and water quality for future reference
66) A well inspection must be performed by a specialty state licensed inspector. This type of inspection is beyond the scope of this general home inspection. If a well inspection is required, recommend contacting the State of Michigan for a list of qualified licensed inspectors.
Limitations: This report only includes findings from accessible and visible areas on the day of the inspection. In addition to the inaccessible areas documented in this report, examples of other inaccessible areas include: sub areas less than 18 inches in height; attic areas less than 5 feet in height, areas blocked by ducts, pipes or insulation; areas where locks or permanently attached covers prevent access; areas where insulation would be damaged if traversed; areas obscured by vegetation. All inaccessible areas are subject to infestation or damage from wood-destroying organisms. The inspector does not move furnishings, stored items, debris, floor or wall coverings, insulation, or other materials as part of the inspection, nor perform destructive testing. Wood-destroying organisms may infest, re-infest or become active at any time. No warranty is provided as part of this inspection.
Visible evidence of active wood-destroying insects: No
Visible evidence of active wood decay fungi: No
Visible evidence of past wood-destroying insects: No
Visible evidence of past wood decay fungi: No
Visible evidence of damage by wood-destroying insects: No
Visible evidence of damage by wood decay fungi: No
Visible evidence of conditions conducive to wood-destroying organisms: No
67) At the time of this inspection, no evidence of WDOs (wood destroying organisms) was observed.
Photo X-1 The width of home as taken from inside. 29'3" Photo X-2 The length of the home as taken from inside. 38' 9"
Photo X-3 Copy of signed inspection agreement
Thank you for choosing me, Home Inspector John, to perform you inspection. Now that you have your report in hand, I want you to know that I am still fully committed and here for you. I believe that even a well written report like this one, if not fully understood, is a useless document which is why I encourage all of my clients to contact me at any time to answer any questions that they may have about their report. Your complete understanding of what this report states is the entire reasoning behind having the property inspected in the first place, and it is my mission to educate and inform all of my clients as best as I can.
Thanks once again for choosing Home Inspector John for your inspection needs. I highly value your opinion and always welcome any suggestions that you may have as I constantly strive to exceed my client's expectations and improve their overall experience. Please feel free to tell me about your inspection experience; things that you liked or didn't like, things that you would've liked to occur or have seen, suggestions, comments, etc. I will gladly use this information to improve my future clients' experience- hopefully some of whom will be referred by you.
Best wishes on the purchase/sale of your home.