Exterior and Foundation
6) 
The masonry (brick or stone) veneer was deteriorated or damaged in some areas. Where cracks or openings are exposed, water can enter the wall structure causing mold, fungal growth and structural damage. This is a conducive condition for wood-destroying organisms. Recommend that a qualified contractor repair as necessary. For example, by repointing mortar or replacing broken or missing masonry.
7) 
Vegetation such as trees, shrubs and/or vines was in contact with or close to the building exterior. Vegetation can serve as a pathway for wood-destroying insects and can retain moisture against the exterior after it rains. This is a conducive condition for wood-destroying organisms. Recommend pruning, moving or removing vegetation as necessary to maintain at least 6 inches of space between it and the building exterior. A 1-foot clearance is better.
8) 
The paint or stain finish in some areas was failing (e.g. peeling, faded, worn, thinning). Siding and trim with a failing finish can be damaged by moisture.Recommend that a qualified contractor prep (e.g. clean, scrape, sand, prime, caulk) and repaint or restain the building exterior where necessary and per standard building practices. Any repairs needed to the siding or trim should be made prior to this.
Peeling paint was observed on the east side of garage exterior.
Cost estimate: $400
9) 
[Some!Many] exterior wall sections were obscured by vegetation and couldn't be fully evaluated. They are excluded from this inspection.
Garage or Carport
15) 


floor areas were obscured by vehicles and couldn't be fully evaluated.
Garage floor was observed to have large cracking that needs to be further evaluated and repaired or replaced as necessary. Estimated cost of replacement 1600-2000 dollars.
16) 
One or more window screens were damaged or deteriorated. These window(s) may not provide ventilation during months when insects are active. Recommend replacing window screens as necessary.
17) 
The paint or stain finish in some areas was failing (e.g. peeling, faded, worn, thinning). Siding and trim with a failing finish can be damaged by moisture.Recommend that a qualified contractor prep (e.g. clean, scrape, sand, prime, caulk) and repaint or restain the building exterior where necessary and per standard building practices. Any repairs needed to the siding or trim should be made prior to this.
18) 
One or more exterior entry doors locked. The inspector was unable to operate or fully evaluate the door(s) as a result.
Rear garage entry door had double cylinder lock with no key available.
19) 
The garage were obscured by stored items and/or vehicle(s). In general, the inspector does not move personal belongings or debris. All areas or items that are obscured, concealed or not readily accessible are excluded from this inspection. The client should be aware that when stored items, vehicle(s) and/or debris are eventually moved, damage or problems that were not noted during the inspection may be found.
Electric
22) 

No arc fault circuit interrupter (AFCI) breakers were installed for bedroom circuits. These are relatively new devices, and reduce the risk of fire by protecting against overheated or arcing receptacles (outlets) or light fixtures. Consult with a qualified electrician about upgrading circuits to AFCI protection per standard building practices. For more information, visit:
http://www.google.com/search?q=arc+fault+circuit+interrupter
23) 

Extension cords were being used as permanent wiring at one or more locations. They should only be used for portable equipment on a temporary basis. Using extension cords as permanent wiring is a potential fire and shock hazard, and indicates that wiring is inadequate and needs updating. Extension cords may be undersized. Connections may not be secure resulting in power fluctuations, damage to equipment, overheating and sparks that could start a fire. Recommend that a qualified electrician repair per standard building practices and eliminate extension cords for permanently.
The rear sunroom was observed to have no permanent outlets wired for service. An extension cord was hard wired into the rear light fixture which is a major fire hazard. Recommend removing the extension cord and installing a permanent outlet(s) for this area.
25) 

No carbon monoxide alarms were visible. This is a potential safety hazard. Some states and/or municipalities require CO alarms to be installed for new construction and/or for homes being sold. Recommend installing approved CO alarms outside of each separate sleeping area in the immediate vicinity of the bedrooms on each level and in accordance with the manufacturer's recommendations. For more information, visit:
http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
27) 

2-slot receptacles (outlets) rather than 3-slot, grounded receptacles were installed in one or more areas. These do not have an equipment ground and are considered unsafe by today's standards. Appliances that require a ground should not be used with 2-slot receptacles. Examples of such appliances include computers and related hardware, refrigerators, freezers, portable air conditioners, clothes washers, aquarium pumps, and electrically operated gardening tools. The client should be aware of this limitation when planning use for various rooms, such as an office. Upgrading to grounded receptacles typically requires installing new wiring from the main service panel or sub-panel to the receptacle(s), in addition to replacing the receptacle(s). Consult with a qualified electrician about upgrading to 3-wire, grounded circuits.
28) 
The electric service to this property appeared to be rated at substantially less than 200 amps and may be inadequate. Depending on the client's needs, recommend consulting with a qualified electrician about upgrading to a 200 amp service. Note that the electric service's rating is based on the lowest rating for the meter base, the service conductors, the main service panel and the main disconnect switch. One or more of these components may need replacing to upgrade.
29) 
Exterior outlets were tested and found to be in serviceable condition.
30) 
Location of main electric service.
Plumbing / Fuel Systems
32) 

One or more leaks were found in water supply pipes or fittings. A qualified plumber should evaluate and repair as necessary.
The fittings that lead to the laundry tub faucet were observe to be leaking. Recommend hiring a qualified professional to repair or replace faucet and fittings as necessary.
33) 

One or more leaks were found in drain pipes or fittings. A qualified plumber should evaluate and repair as necessary.
The p trap in the laundry tub was observed to be leaking. Recommend hiring qualified professional to repair or replace as needed.
Cost estimate: $75
34) 
One or more hose bibs (outside faucets) were not the "frost-free" design, and are more likely to freeze during cold weather than frost-free hose bibs. Recommend that a qualified plumber upgrade these with frost-free hose bibs to prevent freezing, pipes bursting, flooding and possible water damage.
Cost estimate: $50
35) 
Both toilets in the home where observed to have damaged till valves.Recommend hiring a qualified contractor to repair or replace as needed.
36) 

The kitchen sink and both bathroom vanities had personal items stored limiting the visibility of the inspection. Although no leaks or other problem areas were observed, it is recommended that further evaluation be completed after items are removed.
37) 
The gas meter is located in the basement.Recommending contacting gas company to discuss moving to an exterior location.
38) 
Drywall repair was observed in the powder room. According to the owner, plumbing repairs were performed on the upstairs bathroom toilet.
Heating, Ventilation and Air Condition (HVAC)
41) 

Because of the age and/or condition of the forced air furnace, recommend that a qualified HVAC contractor inspect the heat exchanger and perform a carbon monoxide test when it's serviced. Note that these tests are beyond the scope of a standard home inspection.
42) 

The last service date of the forced air electric furnace appeared to be more than 2 years ago, or the inspector was unable to determine the last service date. Ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than 2 years ago, a qualified HVAC contractor should inspect, clean, and service this system, and make repairs if necessary. This servicing should be performed every few years in the future. Any needed repairs noted in this report should be brought to the attention of the contractor when it's serviced.
43) 

The estimated useful life for most heat pumps and air conditioning condensing units is 10-15 years. The inspector was unable to determine the age of this unit. Be aware that it may be near, at, or beyond its useful life and may need replacing or significant repairs at any time. Recommend attempting to determine the age (ask property owner or service technician), and budgeting for a replacement if necessary.
44) 
The estimated useful life for most forced air furnaces is 15-20 years. This furnace appeared to be beyond this age and/or its useful lifespan and may need replacing or significant repairs at any time. Recommend budgeting for a replacement in the near future.
Although 50 years old, this Unit appears to be in serviceable condition.Recommend budgeting for immediate replacement.
45) 
The thermostat was observe to be in serviceable condition.