How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
Safety
Poses a safety hazard
Repair/Replace
Recommend repairing or replacing
Repair/Maintain
Recommend repair and/or maintenance
Evaluate
Recommend evaluation by a specialist
Comment
For your information
Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp
Client present for discussion at end of inspection: No
Weather conditions during inspection: Dry (no rain), Sunny
Temperature during inspection: Warm
Type of building inspected: Single family
Year Built: 1955
Source for main building age: Public records/assessor data
Front of building faces: West
Main entrance faces: West
Occupied: Yes
1) Structures built prior to the mid 1980s may contain lead and/or asbestos. Lead is commonly found in paint and in some plumbing components. The EPA does not recognize newer coats of paint as encapsulating older coats of lead-based paint. Asbestos is commonly found in various building materials such as insulation, siding, and/or floor and ceiling tiles. Laws were passed in 1978 to prohibit usage of lead and asbestos, but stocks of materials containing these substances remained in use for a number of years thereafter. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is beyond the scope of this inspection. Any mention of these materials in this report is made as a courtesy only, and meant to refer the client to a specialist. Consult with specialists as necessary, such as industrial hygienists, professional labs and/or abatement specialists for this type of evaluation.
2) Many areas and items at this property were obscured by furniture and/or stored items. This often includes but is not limited to walls, floors, windows, inside and under cabinets, under sinks, on counter tops, in closets, behind window coverings, under rugs or carpets, and under or behind furniture. Areas around the exterior, under the structure, in the garage and in the attic may also be obscured by stored items. The inspector does not move personal belongings, furnishings, carpets or appliances. When furnishings, stored items or debris are present, all areas that are obscured, concealed or not readily accessible are excluded from the inspection. The client should be aware that when furnishings, stored items or debris are eventually moved, damage or problems that were not noted during the inspection may be found.
Limitations: Unless specifically included in the inspection, the following items and any related equipment, controls, electric systems and/or plumbing systems are excluded from this inspection: detached buildings or structures; fences and gates; retaining walls; underground drainage systems, catch basins or concealed sump pumps; swimming pools and related safety equipment, spas, hot tubs or saunas; whether deck, balcony and/or stair membranes are watertight; trees, landscaping, properties of soil, soil stability, erosion and erosion control; ponds, water features, irrigation or yard sprinkler systems; sport courts, playground, recreation or leisure equipment; areas below the exterior structures with less than 3 feet of vertical clearance; invisible fencing; sea walls, docks and boathouses; retractable awnings. Any comments made regarding these items are as a courtesy only.
Site profile: Level, Minor slope, moderately sloped back yard
Driveway material: Gravel
Sidewalk material: Wood
3) A lean-to structure attached to or in contact with the building exterior without proper connections and flashings. Such attachments can serve as a pathway for wood destroying insects and can retain moisture against the exterior after it rains. This is a condition conducive to attracting wood destroying organisms. I recommend a qualified licensed general contractor or other qualified party to repair as necessary to properly shed rain/water.
4) The shed at the Southeast corner of the property was noted with excessive moisture readings and evidence of wood-destroying insects. This can be harmful to the integrity of the structural members. I recommend further evaluation and mitigation to be completed by licensed pest control contractor and any necessary repairs to be completed by a qualified licensed general contractor.
Limitations: The inspector performs a visual inspection of accessible components or systems at the exterior. Items excluded from this inspection include below-grade foundation walls and footings; foundations, exterior surfaces or components obscured by vegetation, stored items or debris; wall structures obscured by coverings such as siding or trim. Some items such as siding, trim, soffits, vents and windows are often high off the ground, and may be viewed using binoculars from the ground or from a ladder. This may limit a full evaluation. Regarding foundations, some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determine the adequacy of seismic reinforcement.
Deck, patio, porch cover material and type: Open, Covered (Refer to Roof section), Open rear patio, covered South and West patios
Deck, porch and/or balcony material: Wood
Exterior stair material: Wood
5) Elevated moisture levels were noted along with visible signs of moisture intrusion throughout the South-facing porch roof structure. This is a condition conducive to rot and/or other wood-destroying organisms. I recommend further evaluation and necessary repairs to be completed by a qualified licensed general contractor.
6) The East-facing balcony stairs were noted as incomplete and damaged by rot and other wood-destroying organisms. This can be a safety hazard. I recommend evaluation and necessary repairs to be completed by a qualified and licensed general contractor.
7) Evidence of wood-destroying insects was noted at several locations including the exterior siding near the East-facing entrance, in the incomplete stairway attached to the East-facing balcony, throughout the shed structure, as well as floor joists near both crawl space entrances. This can spread throughout the home and threaten the integrity of structural members. I recommend further evaluation and proper remediation to be completed by qualified and licensed pest control contractor. Any necessary repair or replacement to be completed by qualified and licensed general contractor.
8) Soil was in contact with or less than 6 inches from siding, trim or structural wood. This condition is conducive to attracting wood destroying organisms. I recommend grading or removing soil as necessary to maintain a 6-inch clearance. If that's not possible, have a qualified general contractor replace untreated wood with rot resistant pressure-treated lumber. Since even pressure-treated materials can eventually decay, plan to periodically check the condition of any wood that is in contact with earth. Note that damage from fungal rot and/or insects may be discovered when soil is removed, and further repairs and wood replacement may be necessary.
9) Fungal rot was found in support posts and/or lattice boards at some of the structures covering decks, patios and/or porches. Rot will spread and it weakens lumber. I recommend that a qualified general contractor remove/replace/repair materials as necessary.
10) The dryer exhaust vent was noted with damaged or missing louvers. This can become an entry point for pests and vermin. I recommend repair/replacement by qualified party.
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; solar roofing components. Any comments made regarding these items are made as a courtesy only. Note that the inspector does not provide an estimate of remaining life on the roof surface material, nor guarantee that leaks have not occurred in the roof surface, skylights or roof penetrations in the past. Regarding roof leaks, only active leaks, visible evidence of possible sources of leaks, and evidence of past leaks observed during the inspection are reported on as part of this inspection. The inspector does not guarantee or warrant that leaks will not occur in the future. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high wind and rain, melting snow) would be needed to do so. Occupants should monitor the condition of roofing materials in the future. For older roofs, I recommend that a professional review the roof surface, flashings, appurtenances, etc. annually and maintain/repair as might be required. If needed, the roofer should enter attic space(s). Regarding the roof drainage system, unless the inspection was conducted during and after prolonged periods of heavy rain, the inspector was unable to determine if gutters, downspouts and extensions perform adequately or are leak-free.
Roof inspection method: Traversed
Roof surface material: Rolled composition
Roof type: Flat or low slope
Gutter material: Aluminum
Downspout material: Aluminum
11) Downspout extensions such as splash blocks or drain pipes were missing. Water can accumulate around the building foundation or inside crawl spaces or basements. I recommend that a qualified person install, replace or repair extensions as necessary so rainwater drains away from the structure.
Limitations: The following items are not included in this inspection: generator systems, transfer switches, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low-voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, if this system has an adequate capacity for the client's specific or anticipated needs, or if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, and does not install or change light bulbs. The inspector does not evaluate every wall switch or receptacle, but instead tests a representative number of them per various standards of practice. When furnishings, stored items or child-protective caps are present some receptacles are usually inaccessible and are not tested; these are excluded from this inspection. Receptacles that are not of standard 110 volt configuration, including 240-volt dryer receptacles, are not tested and are excluded. The functionality of, power source for and placement of smoke and carbon monoxide alarms is not determined as part of this inspection. Upon taking occupancy, proper operating and placement of smoke and carbon monoxide alarms should be verified and batteries should be changed. These devices have a limited lifespan and should be replaced every 10 years. The inspector attempts to locate and evaluate all main and sub-panels. However, panels are often concealed. If panels are found after the inspection, a qualified electrician should evaluate and repair if necessary. The inspector attempts to determine the overall electrical service size, but such estimates are not guaranteed because the overall capacity may be diminished by lesser-rated components in the system. Any repairs recommended should be made by a licensed electrician.
Primary service type: Overhead
Number of service conductors: 3
Service voltage (volts): 120-240
Estimated service amperage: 200
Primary service overload protection type: Circuit breakers
Service entrance conductor material: Stranded aluminum
System grounding method: Ground electrode(s) in soil
Make of main panel(s): Sylvania
Main disconnect rating (amps): 200
Location of main disconnect: Breaker at top of main service panel
Location of main service panel #1: Bedroom, First floor bedroom
Make of sub/remote distribution panel(s): Sylvania
Location of sub/remote distribution-panel #1: Bedroom, Upstairs Northern bedroom
Ground fault circuit interrupter (GFCI) protection present: No
Arc fault circuit interrupter (AFCI) protection present: No
12) At least one electric receptacle(s) at the bedroom(s), kitchen, living room, hallway(s) and/or laundry area had no visible arc fault circuit interrupter (AFCI) protection, or the inspector was unable to determine if AFCI protection was present. AFCI protection reduces the risk of fire by guarding against circuits that are overheating or arching. I recommend that a qualified electrical contractor evaluate and, as necessary, install AFCI protection per standard safety guidelines. At the present time, AFCI protection guidelines require the devices at most 120 volt household branch circuits. Rule changes over the years are typically not retroactive but, depending on the scope of the project, if wiring is modified in the future, the permitting process could trigger compulsory upgrades. A diagram, illustrative of the recommended placement for AFCI and GFCI (ground fault) protection, is available at this link: https://goo.gl/f62RMB
13) Handle ties were substandard at a 2-pole or ganged 1-pole circuit breaker at a panel. This is a safety concern, approved handle ties should be installed to prevent one side of the breaker from being turned on or off while the other half remains static. Nails, screws, wires or other nonconforming material are not permitted for use as handle ties. I recommend that a qualified electrical contractor evaluate and repair/replace as necessary.
The main disconnect handle tie was noted as loose and ill-fitting.
14) Neutral and equipment ground wires were bonded (connected) at an electric sub-panel. This should only occur in the main service panel, not sub-panels, and it is a safety hazard. Neutral wires should be attached to a "floating" neutral bar not bonded to the panel, and grounding wires should be attached to a separate grounding bar bonded to the sub-panel. I recommend that a qualified electrical contractor evaluate and repair/replace as necessary.
15) At least one modern 3-slot electric receptacles, with an open or missing ground, was identified on the premises. Any such receptacles do not have equipment ground(s), when present equipment grounds enhance occupant safety, and are considered antiquated wiring by today's standards. Any tools, appliances and equipment that is designed to be grounded should not be plugged into receptacles that are lacking equipment grounds. I recommend that a qualified electrical contractor evaluate and upgrade/repair/replace wiring and system as necessary. Upgrading to grounded receptacles typically requires installing new wiring from the main service panel or sub-panel to the receptacle(s), in addition to replacing the receptacle(s). If rewiring is not an option, due to financial considerations, often 3-slot ungrounded receptacles will be replaced with 2-slot receptacles.
16) Branch circuit wiring installed in buildings built prior to the mid 1980s is typically rated for a maximum temperature of only 60 degrees Celsius. This includes non-metallic sheathed (Romex) wiring, and both BX and AC metal-clad flexible wiring. Knob and tube wiring, typically installed in homes built prior to 1950, may be rated for even lower maximum temperatures. Newer electric fixtures including lighting and fans typically require wiring rated for 90 degrees Celsius. Connecting newer fixtures to older, 60-degree-rated wiring is a potential fire hazard. Repairs for such conditions may involve replacing the last few feet of wiring to newer fixtures with new 90-degree-rated wire, and installing a junction box to join the old and new wiring.
It is beyond the scope of this inspection to determine if such incompatible components are installed, or to determine the extent to which they're installed. Based on the age of this building, the client should be aware of this safety hazard, both for existing fixtures and when planning to upgrade with newer fixtures. I recommend that a qualified electrical contractor evaluate and repair/replace as necessary.
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood-fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating or cooling system components, does not determine if heating or cooling systems are appropriately sized, does not test coolant pressure, or perform any evaluations that require a pilot light to be lit, a shut-off valve to be operated, a circuit breaker to be turned "on" or a serviceman's or oil emergency switch to be operated. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future. Where buildings contain furnishings or stored items, the inspector may not be able to verify that a heat source is present in all "liveable" rooms (e.g. bedrooms, kitchens and living/dining rooms).
Heating system type(s): Heat pump, Several ductless systems
Location of main heating appliance: Not applicable, dedicated heat sources are present in individual rooms
Gas meter location: South side of house
Cooling or heat pump system type(s): Ductless heat pump
Limitations: The following items are not included in this inspection: coal stoves, gas logs, chimney flues (except where visible). Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of drafting or sizing in fireplace and stove flues, and also does not determine if prefabricated or zero-clearance fireplaces are installed in accordance with the manufacturer's specifications. The inspector does not perform any evaluations that require a pilot light to be lit, and does not light fires. The inspector provides a basic visual examination of a chimney and any associated wood burning device. The National Fire Protection Association has stated that an in-depth Level 2 chimney inspection should be part of every sale or transfer of property with a wood-burning device. Such an inspection may reveal defects that are not apparent to the home inspector who is a generalist.
Limitations: Evaluation of and determining the adequacy or completeness of the following items are not included in this inspection: water recirculation pumps; solar water heating systems; Energy Smart or energy saver controls; catch pan drains. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit or a shut-off valve to be operated.
Make of water heater(s): A.O. Smith
Estimated age: 2019
Capacity (in gallons): 50
Type: Tank
Energy source: Electricity
Device operational at time of inspection: Yes
Location of water heater: Laundry room
Water temperature (degrees Fahrenheit): 125f
Seismic straps installed at tank water heater: Yes
Temperature-pressure relief valve and drain line installed: Valve present, but missing or defective drain line
Catch pan/drain line present under tank at finished interior space: Catch pan apparent, but missing a drain line
17) The temperature-pressure relief valve is missing a drain line. This is a potential safety hazard that increases the risk of a scalding burn. I recommend that a qualified plumber install a drain line in accordance with standard guidelines.
Limitations: The following items are not included in this inspection: private/shared wells and related equipment; private sewage disposal systems; hot tubs or spas; main, side and lateral sewer lines; gray water systems; pressure boosting systems; trap primers; incinerating or composting toilets; fire suppression systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determine the existence or condition of underground or above-ground fuel tanks.
Water service type: Public
Main system water pressure (psi): 80psi
Location of municipal/community connections/shutoffs and/or water meter (customarily located below grade): Not verified. Typically located at/below grade near the street or an alley
Location of "occupant accessible" main water shutoff valve: Crawl space
Waste system type: Municipal sewer (underground pipes are excluded)
Location waste/drain system main cleanout(s): East yard near crawl space entrance
Plumbing vent stack or vent stacks present: Yes, more than one vent was noted. The inspector verifies that vents are present, but does not perform detailed analysis of the adequacy of stacks
Service pipe material: Polyethylene plastic
Supply pipe material: Copper, PEX plastic
Drain/waste pipe material: ABS plastic
Vent pipe material: ABS plastic
18) A leak was detected at the connection for the hose faucet near the West-facing porch. A qualified plumbing contractor should evaluate and repair as necessary.
19) Some electric bonding or grounding clamps were installed on copper water supply pipes and the clamps were made with a metal other than copper (e.g. steel). There was also a galvanized steel fitting attached to copper pipe. Contact between such dissimilar metals causes corrosion and can damage the water supply pipes. I recommend that a qualified licensed plumber replace clamp(s) as necessary.
Limitations: Structural components such as joists and beams, and other components such as piping, wiring and/or ducting that are obscured by under-floor insulation are excluded from this inspection. The inspector does not determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.
The inspector does not guarantee or warrant that water will not accumulate in the crawl spaces in the future. Complete access to all crawl space areas during all seasons and during prolonged periods of all types of weather conditions (e.g. heavy rain, melting snow) would be needed to do so.
The inspector attempts to locate all crawl space access points and areas. Access points may be obscured or otherwise hidden by furnishings or stored items. In such cases, the client should ask the property owner where all access points are that are not described in this inspection, and have those areas inspected. Note that crawl space areas should be checked at least annually for water intrusion, plumbing leaks and pest activity.
Crawl space inspection method: Traversed
Apparent foundation type: Crawl space
Foundation wall/stem wall material: Poured in place concrete
Footing material (under foundation stem wall): Poured in place concrete
Foundation sill plate bolts: No, older home typical. When present, bolts better attach a home to a foundation in the event of seismic activity
Pier or support post material: Wood
Beam material: Wood
Floor structure above: Solid wood joists
Insulation material underneath floor: Fiberglass roll or batt
Vapor barrier present: Yes
Ventilation type: Unconditioned space, with vents
20) Under-floor insulation was falling down in some areas. This will result in reduced energy efficiency. I recommend that a qualified person repair or replace insulation as necessary.
Limitations: The following items are not included in this inspection: household appliances such as stoves, ovens, cook tops, ranges, warming ovens, griddles, broilers, dishwashers, trash compactors, refrigerators, freezers, ice makers, hot water dispensers and water filters; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances. The inspector does not note appliance manufacturers, models or serial numbers and does not determine if appliances are subject to recalls. Areas and components behind and obscured by appliances are inaccessible and are excluded from this inspection.
Range, cooktop, oven energy source: Not verified, range, etc. excluded
Ventilation kitchen/range: Hood or built into microwave over range or cooktop
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Locations/bathroom types: Full bath main floor, Master bath upper floor
Bathroom and laundry ventilation type: Windows, Spot exhaust fans, with individual ducts
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; cosmetic deficiencies such as nail-pops, scuff marks, dents, dings, blemishes or issues due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window, drawer, cabinet door or closet door operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, I recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Carpeting and flooring, when installed over concrete slabs, may conceal moisture. If dampness wicks through a slab and is hidden by floor coverings that moisture can result in unhygienic conditions, odors or problems that will only be discovered when/if the flooring is removed. Determining the cause and/or source of odors is not within the scope of this inspection.
Exterior door(s) types/materials: See "exterior" report section
Exterior window(s) types/materials: See "exterior" report section
Interior wall type or covering: Drywall
Flooring type or covering(s): Carpet, Vinyl, linoleum or marmoleum, Wood or wood products, Laminate
Ceiling type or covering: Drywall or plaster
21) Condensation or staining was visible between multi-pane glass in a few windows. This usually indicates that the seal between the panes of glass has failed or that the desiccant material that absorbs moisture is saturated. As a result, the view through the window may be obscured, the window's R-value will be reduced, and accumulated condensation may leak into the wall structure below. I recommend that a qualified contractor evaluate and repair windows as necessary. Usually, this means replacing the glass in window frames.
Be aware that evidence of failed seals or desiccant material may be more or less visible depending on the temperature, humidity, sunlight, etc. Windows or glass-paneled doors other than those that the inspector identified may have failed and require glass replacement. It is beyond the scope of this inspection to identify every window with failed seals or desiccant.