Summary

Client(s):  Home Buyer
Property address:  123 Avenue Rd
Hometown, MO 12345
Inspection date:  Monday, May 1, 2023

This report published on Monday, May 1, 2023 12:18:04 PM CDT

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

Concerns are shown and sorted according to these types:
Concern typeSafetyPoses a safety hazard
Concern typeRepair/ReplaceRecommend repairing or replacing
Concern typeRepair/MaintainRecommend repair and/or maintenance
Concern typeMaintainRecommend ongoing maintenance
Concern typeEvaluateRecommend evaluation by a specialist
Concern typeMonitorRecommend monitoring in the future
Concern typeCommentFor your information


Exterior and Foundation
1) Fungal rot was found at one or more sections of siding or trim and/or window sills. Conducive conditions for rot should be corrected (e.g. wood-soil contact, reverse perimeter slope). Recommend that a qualified person repair as necessary. All rotten wood should be replaced.
Photo
Photo 1-1 Wood siding/concrete contact. Rot. Back patio.
Photo
Photo 1-2 Rot around several window frames
Photo
Photo 1-3 
2) Vegetation such as trees, shrubs and/or vines was in contact with or close to the building exterior. Vegetation can serve as a pathway for wood-destroying insects and can retain moisture against the exterior after it rains. This is a conducive condition for wood-destroying organisms. Recommend pruning, moving or removing vegetation as necessary to maintain at least 6 inches of space between it and the building exterior. A 1-foot clearance is better.
Photo
Photo 2-1 Vines on soffit, bricks, window frame
3) The paint or stain finish in some areas was failing (e.g. peeling, faded, worn, thinning). Siding and trim with a failing finish can be damaged by moisture. Recommend that a qualified contractor prep (e.g. clean, scrape, sand, prime, caulk) and repaint or restain the building exterior where necessary and per standard building practices. Any repairs needed to the siding or trim should be made prior to this.
Photo
Photo 3-1 Failing paint on many areas of soffit
4) Caulk was deteriorated in some areas. For example, around doors. Recommend that a qualified person renew or install caulk as necessary. Where gaps are wider than 1/4 inch, an appropriate material other than caulk should be used. For more information, visit:
http://www.reporthost.com/?CAULK
Photo
Photo 4-1 Caulking deteriorated where wood siding meets brick. Back patio.

Basement
5) One or more exterior doors were significantly damaged or deteriorated. Recommend that a qualified person replace door(s) as necessary.
6) Fungal rot was found at one or more exterior door jambs. Recommend that a qualified person repair as necessary. All rotten wood should be replaced.
Photo
Photo 6-1 Failing paint and rot around basement door jamb.
7) One or more exterior doors were difficult to open or close. Recommend that a qualified person repair as necessary.
8) One or more windows were at or below grade with vegetation/soil in the wells. Wells should be cleaned out when windows are at or near grade to prevent soil from contacting the structure and causing fungal rot or moisture problems. This is a conducive condition for wood-destroying organisms. Recommend that a clearing out the vegetation and soil.
Photo
Photo 8-1 Vegetation growing in basement window wells

Roof
9) Extensions such as splash blocks or drain pipes for one or more downspouts were missing and/or damaged. Water can accumulate around the building foundation or inside crawl spaces or basements as a result. Recommend that a qualified person install, replace or repair extensions as necessary so rainwater drains away from the structure.
Photo
Photo 9-1 Disconnected and damaged downspout extension
Photo
Photo 9-2 Damaged downspout extension
10) One or more downspouts or elbows were loose or detached. Rainwater can come in contact with the building exterior or accumulate around the foundation as a result. This is a conducive condition for wood-destroying organisms and water entry. Recommend that a qualified person repair as necessary.
Photo
Photo 10-1 Downspout disconnected. Water stains and moss growing on exterior
11) Significant amounts of debris have accumulated in one or more gutters or downspouts. Gutters can overflow and cause water to come in contact with the building exterior, or water can accumulate around the foundation. This is a conducive condition for wood-destroying organisms. Recommend cleaning gutters and downspouts now and as necessary in the future.
Photo
Photo 11-1 Clogged gutters
Photo
Photo 11-2 Clogged gutters

Garage or Carport
12) One or more areas with missing or substandard surface materials were found in the attached garage walls or ceilings. Current standard building practices call for wooden-framed ceilings and walls that divide the house and garage to provide limited fire-resistance rating to prevent the spread of fire from the garage to the house. Recommend that a qualified person repair per standard building practices. For example, by patching openings or holes, firestopping holes or gaps with fire-resistant caulking, and/or installing fire-resistant wall covering (e.g. Type X drywall). For more information, visit:
http://www.reporthost.com/?AGFR
13) The automatic opener for one or more garage vehicle doors didn't reverse when the photoelectric sensors were blocked. These sensors should reverse the door when closing to prevent injury when a person or pet passes through the sensors' beam. This is a safety hazard. A qualified person should repair as necessary. For more information on garage door safety issues, visit:
http://www.reporthost.com/?GDPES
Photo
Photo 13-1 Photoelectric garage sensors inoperable

Electric
14) One or more ground fault circuit interrupter (GFCI) receptacles (outlets) wouldn't trip with a test instrument at the bathroom(s). This is a potential shock hazard. Recommend that a qualified electrician evaluate and repair as necessary.
Photo
Photo 14-1 GFCI outlets in hall bathroom showing open ground and would not trip with tester
Photo
Photo 14-2 GFCI would not trip with tester
15) One or more ground fault circuit interrupter (GFCI) type receptacles (outlets) had an open ground. Open ground GFCI receptacles will trip, but they won't provide a grounded electric supply for appliances that need them. This is a potential shock hazard. Recommend that a qualified electrician repair per standard building practices. For example, by upgrading to grounded, 3-conductor wiring. In older dwellings constructed when GFCI protection was not required, and in areas where GFCI protection is not required, replacing 3-slot GFCI receptacles with 2-slot receptacles may be an acceptable repair.
Photo
Photo 15-1 GFCI outlets in hall bathroom showing open ground and would not trip with tester
16) One or more electric receptacles exterior had no visible ground fault circuit interrupter (GFCI) protection, or the inspector was unable to determine if GFCI protection was present. If not GFCI-protected, receptacles in wet areas pose a shock hazard. Recommend that a qualified electrician evaluate and install GFCI protection if necessary and per standard building practices. General guidelines for GFCI-protected receptacles include the following locations:
Outdoors (since 1973)
Bathrooms (since 1975)
Garages (since 1978)
Kitchens (since 1987)
Crawl spaces and unfinished basements (since 1990)
Wet bar sinks (since 1993)
Laundry and utility sinks (since 2005)
For more information, visit:
http://www.reporthost.com/?GFCI
Photo
Photo 16-1 Exterior outlet by front door not GFCI protected and gang box is loose
17) One or more cover plates for switches, receptacles (outlets) or junction boxes were missing or broken. These plates are intended to contain fire and prevent electric shock from occurring due to exposed wires. Recommend that a qualified person install cover plates where necessary.
Photo
Photo 17-1 Junction boxes in attic were missing covers
Photo
Photo 17-2 Junction boxes in garage are missing covers
18) Batteries in all the smoke alarms should be replaced after taking occupancy, and annually in the future. "Chirping" noises emitted from smoke alarms typically indicate that batteries need replacing. For more information, visit:
http://www.reporthost.com/?SMKALRM
Photo
Photo 18-1 CO detector in basement is missing battery
19) One or more ground fault circuit interrupter (GFCI) receptacles or circuit breakers were defective. Because of this, the inspector was unable to determine if all electric receptacles that should be protected by GFCI devices, were protected. After defective GFCI devices have been replaced or repaired, recommend that a qualified electrician verify that receptacles throughout the house have GFCI protection per standard building practices, and make repairs if necessary.

Plumbing / Fuel Systems
21) The gas meter was obscured by vegetation. A minimum clear area of 3 feet should exist in front of and on both sides of the meter. Recommend that vegetation be cleared as necessary to maintain clearances per standard building practices.
Photo
Photo 21-1 
Photo
Photo 21-2 Gas meter is covered with vines/vegetation
22) One or more propane or natural gas supply terminations were unused (no appliance connected) and no cap was installed on the gas shut-off valve(s). Gas can flow directly out of the termination with the shut-off valve is opened. This is a potential fire hazard. Recommend that a qualified person install caps where missing per standard building practices.
Photo
Photo 22-1 Unused gas line not properly capped in basement

Heating, Ventilation and Air Condition (HVAC)
23) One or more electric baseboard heaters were inoperable. Recommend that a qualified electrician repair or replace as necessary.

The electric baseboard heater in the basement did not respond to it's controls.
24) Air filters for the heating and/or cooling system were missing or incorrect size at one or more locations. Indoor air quality will be reduced as a result. Recommend installing good quality filters at intended locations (e.g. in or at the air handler, behind return air grills). Filters should be sized correctly to minimize air gaps. Many types of filters are available. Recommend installing pleated filters or better rather than the cheapest disposable kind. For more information, visit:
http://www.reporthost.com/?FLTRTPS
Photo
Photo 24-1 Wrong size filters in HVAC plenum/air handler

Fireplaces, Stoves, Chimneys and Flues
26) One or more wood-burning fireplaces or stoves were found at the property. When such devices are used, they should be professionally inspected and cleaned annually to prevent creosote build-up and to determine if repairs are needed. The National Fire Protection Association states that a "Level 2" chimney inspection should be performed with every sale or transfer of property with a wood-burning device. Recommend consulting with the property owner about recent and past servicing and repairs to all wood-burning devices and chimneys or flues at this property. Recommend that a qualified specialist evaluate all wood-burning devices and chimneys, and clean and repair as necessary. Note that if a wood stove insert is installed, it may need to be removed for such an evaluation. For more information, search for "chimney inspection" at:
http://www.reporthost.com/?CSIA

Bathrooms, Laundry and Sinks
27) The sink at the wet bar was inoperable. Recommend that a qualified contractor repair or replace the sink.
Photo
Photo 27-1 Wet bar sink in basement is inoperable
28) One or more sink drains were leaking at location(s) # A. A qualified person should repair as necessary.
Photo
Photo 28-1 Minor leak/drip in master bath p-trap under right sink
29) The hot and cold water supply flow for the shower at location(s) #C was inoperable. Recommend that a qualified plumber evaluate and repair as necessary.
Photo
Photo 29-1 Plumbing to shower in basement bathroom is disconnected
30) The sink at location(s) #A and B drained slowly. Recommend clearing drain and/or having a qualified plumber repair if necessary.
Photo
Photo 30-1 Hall bathroom sinks are slow draining
Photo
Photo 30-2 Right sink in master bath is slow draining

Interior, Doors and Windows
31) One or more sections of ceilings were sagging. Recommend that a qualified contractor evaluate and repair as necessary.
Photo
Photo 31-1 Acoustic tile ceiling sagging in several places in basement
Photo
Photo 31-2 Acoustic tile ceiling sagging in several places in basement
32) One or more windows that were designed to open and close were stuck shut. Recommend that a qualified person repair windows as necessary so they open and close easily.
Photo
Photo 32-1 One window in master bedroom is stuck shut and both are missing their lock mechanisms
33) Glass in one or more windows was broken. Recommend that a qualified contractor replace glass where necessary.
Photo
Photo 33-1 Fixed window in master bedroom is cracked/chipped
34) Minor water damage/stains were found in one or more wall areas. The inspector was unable to determine if an active leak exists. Recommend asking the property owner about this, monitoring the stains/damage area in the future, and/or having a qualified contractor evaluate and repair if necessary.
Photo
Photo 34-1 Minor water damage on walls next to basement door
35) One or more "pocket" doors were stuck or difficult to operate. Recommend that a qualified person repair as necessary.
36) Lock mechanisms on one or more windows were missing. This can pose a security risk. Recommend that a qualified person repair as necessary.
Photo
Photo 36-1 One window in master bedroom is stuck shut and both are missing their lock mechanisms