View as PDF

View summary

K.D.Milton's Home Inspections

Inspector: Kenneth Milton
Inspector's email: kdmhi@protonmail.com
Inspector's phone: (951) 966-3520

Home Inspection Report by K.D. Milton's Home Inspections

Client(s):  Tim Buck Too
Property address:  1234 Maple St.
Anywhere USA
Inspection date:  Sunday, December 11, 2022

This report published on Monday, December 12, 2022 8:04:58 AM PST

K.D. Milton's Home Inspection

How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
Concern typeRepair/ReplaceRecommend repairing or replacing
Concern typeRepair/MaintainRecommend repair and/or maintenance
Concern typeEvaluateRecommend evaluation by a specialist
Concern typeCommentFor your information

Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp

Table of Contents

General Information
Electrical
Roof
Heating/Air Conditioning
Plumbing

View summary

General Information
Table of contents
Job #: 1111
Date of inspection: 12-31-2022
Property's address: 1234 Maple St.
Property's city, state, zip code: Anywhere USA
Type of construction: Wood frame
Type of foundation: Slab on grade
Number of stories: 1
Approximate square feet: 2000
Approximate age of home: 25 years
Client/owner's name: Tim Buck Too
Inspector's name: Ken Milton
Inspector's company name: K.D. Milton's Home Inspections
Inspector's email address: kdmhi@protonmail.com
Note: A Four-Point Insurance Inspection is typically performed for a homeowner when requested by their insurance company to obtain a new insurance policy or renewing an existing policy.

A Four-Point Insurance Inspection is far less in scope than a standard home inspection. This Four-Point Insurance Inspection is a limited, visual survey of the heating/air conditioning, roof, electrical and plumbing systems.
4 Point Disclaimer: A four-point Inspection is often required when obtaining a new homeowners insurance policy or renewing an existing policy. Often they are used by homeowners that have bought a new home and are close to their builders year warranty. This 4-point inspection includes a limited, visual scope evaluation of the following four systems:(1) electrical(2) roofing(3) heating-air conditioning(4) plumbing. The focus of the inspection is to determine the approximate age, components, and general condition of these systems. Note: this type of inspection should not be confused with a "standard home inspection" which is more comprehensive in regards to both detail and scope.
Electrical
Table of contents
Service amps: 200
Size of service sufficient: Yes
Fuses or circuit breakers: Circuit breakers
Main panel location: Building exterior
Panel ground observed: Yes
GFCIs present where required: No
AFCIs present in bedrooms: No
Aluminum branch circuits: No
Active knob and tube wiring: No
Condition of panels and wiring: Serviceable
Exposed or unsafe wiring noticed: No
Recent upgrades: No
Overall electrical system condition: Serviceable
Electrical comments:
Limitations: The following items are not included in this inspection: generator systems, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, does not determine if this system has an adequate capacity for the client's specific needs, nor determine if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, install or change light bulbs, nor determine the operability of every wall switch.
1) A/C breaker was too small. Recommend replacing with a breaker that will not be damaged and possibly cause a fire.
Photo
Photo 1-1 A/C
Photo
Photo 1-2 
2) Any electrical repairs attempted by anyone other than a licensed electrician should be approached with caution. The power to the entire house should be turned off prior to beginning any repair efforts, no matter how trivial the repair may seen. Aluminum wiring requires periodic inspection and maintenance by a licensed electrician. Operation of time clock motors is not verified. Inoperative light fixtures often lack bulbs or have dead bulbs installed. Light bulbs are not changed during the inspection, due to time constraints. Smoke Alarms should be installed within 15 feet of all bedroom doors, and tested regularly. National safety standards require electrical panels to be weatherproof, readily accessible, and have a minimum of thirty-six inches of clear space in front of them for service. Also, they should have a main disconnect, and each circuit within the panel should be clearly labeled. Industry standards only require us to test a representative number of accessible switches, receptacles, and light fixtures. However, we attempt to test every one that is unobstructed, but if a residence is furnished we will obviously not be able to test each one.
Photo
Photo 2-1 Service main
Photo
Photo 2-2 Open panel
Roof style: Gable
Type of roof covering: Concrete tile
Estimated age of roof covering: 25 years
Type of sheathing: Plywood
Flashing damage noticed: No
Missing shingles or covering: No
Trusses or rafter damage noticed: No
Evidence of active leaks: Yes
Estimated life expectancy: 50-100 years
Roof comments: The roof is 25 years old and has never had any maintenance. Recommend having a licensed roofing contractor evaluate further.
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation; solar roofing components; any comments made regarding these items are as a courtesy only. Note that the inspector does not determine if rafters, trusses, joists, beams, etc. are of adequate size, spanning or spacing. The inspector does not provide an estimate of remaining roof surface life, does not determine that the roof has absolutely no leaks at the time of the inspection, and does not determine that the roof won't leak in the future. Only active leaks and evidence of past leaks observed during the inspection are reported on as part of this inspection. To absolutely determine than no leaks exist, complete access to all roof structure areas must be available during a wide variety of weather conditions, including prolonged heavy rain, high wind from varying directions, heavy accumulations of snow and/or ice, and melting snow and ice.
3) One or more roofing tiles are chipped and/or cracked. A qualified licensed handyman/roofing contractor should evaluate and replace tiles as necessary. For more information: http://voices.yahoo.com/diy-repairing-crack-concrete-roof-tile-6904868.html
Photo
Photo 3-1 Roof
Photo
Photo 3-2 Roof
Photo
Photo 3-3 Roof
Heating/Air Conditioning
Table of contents
Types of heating systems: Forced air
Estimated age of heating systems: 25 years
Heating systems upgraded: No
Condition of heating systems: Near end of service life
Heating system comments: Recommend servicing the heating system due to its age,
Types of cooling systems: Split system
Estimated age of cooling systems: 25 years
Cooling systems upgraded: No
Condition of cooling systems: Near end of service life
Cooling system comments: Recommend servicing the cooling system due to its age,
Furnace Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating system components, does not determine if heating systems are appropriately sized, or perform any evaluations that require a pilot light to be lit. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks.
A/C Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; thermostat or temperature control accuracy and timed functions; cooling components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on cooling system components, does not determine if cooling systems are appropriately sized, and does not test coolant pressure. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future.
4) The air handler's filter(s) are damaged and/or deteriorated and should be replaced.
Photo
Photo 4-1 Filter
5) The system was working / not working during the inspection.The last service date of this system appears to be more than two years ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than two years ago, a qualified licensed handyman/heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. This servicing should be performed every few years in the future, or as per the contractor's recommendations.
Photo
Photo 5-1 A/C
Photo
Photo 5-2 Furnace
Number of bathrooms: 3
Overall water pressure: 60 psi
Main supply line material: Not determined
Main waste/vent material: Plastic
Fixture supply line material: Copper
Fixture drain line material: Plastic
Shut off valves present: Yes
Water heater location: Garage
Water heater fuel type: Natural gas
Approximate age of water heater: 10 years
Temperature pressure relief valve present: Yes
Fire sprinkler system present: No
Freeze hazards noticed: No
Polybutylene noticed: No
Plumbing leaks noticed: No
Recent plumbing upgrades: No
Overall plumbing condition: Serviceable
Plumbing comments:
Limitations: The following items are not included in this inspection: private wells and sewage disposal systems; main, side and lateral sewer lines; gray water systems; pressure boosting systems; incinerating or composting toilets; fire suppression sprinkler systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determining the existence or condition of underground or above-ground fuel tanks.
6) One or more sink drains have an active leak. For example, at pipe fittings and/or junctions between pipe and sink. A qualified licensed handyman/plumber should evaluate and repair as necessary.
Photo
Photo 6-1 Leaks
Photo
Photo 6-2 Leaks
7) The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be beyond this age and/or its useful lifespan and may need replacing at any time. Recommend budgeting for a replacement in the near future.
Photo
Photo 7-1 Water heater
8) The water pressure is at or less than 80 psi and more than 40 psi. Pressure over 80 psi may void warranties for some appliances. For more information: https://www.youtube.com/watch?v=lNAAzs4C-lQ
Photo
Photo 8-1 Water pressure


REPORT LIMITATIONS

This report is intended only as a general guide to help the client make his own evaluation of the overall condition of the home, and is not intended to reflect the value of the premises, nor make any representation as to the advisability of purchase. The report expresses the personal opinions of the inspector, based upon his visual impressions of the conditions that existed at the time of the inspection only. The inspection and report are not intended to be technically exhaustive, or to imply that every component was inspected, or that every possible defect was discovered. No disassembly of equipment, opening of walls, moving of furniture, appliances or stored items, or excavation was performed. All components and conditions which by the nature of their location are concealed, camouflaged or difficult to inspect are excluded from the report.

Systems and conditions which are not within the scope of the building inspection include, but are not limited to: formaldehyde, lead paint, asbestos, toxic or flammable materials, and other environmental hazards; pest infestation, playground equipment, efficiency measurement of insulation or heating and cooling equipment, internal or underground drainage or plumbing, any systems which are shut down or otherwise secured; water wells (water quality and quantity) zoning ordinances; intercoms; security systems; heat sensors; cosmetics or building code conformity. Any general comments about these systems and conditions are informational only and do not represent an inspection.

The inspection report should not be construed as a compliance inspection of any governmental or non governmental codes or regulations. The report is not intended to be a warranty or guarantee of the present or future adequacy or performance of the structure, its systems, or their component parts. This report does not constitute any express or implied warranty of merchantability or fitness for use regarding the condition of the property and it should not be relied upon as such. Any opinions expressed regarding adequacy, capacity, or expected life of components are general estimates based on information about similar components and occasional wide variations are to be expected between such estimates and actual experience.

We certify that our inspectors have no interest, present or contemplated, in this property or its improvement and no involvement with tradespeople or benefits derived from any sales or improvements. To the best of our knowledge and belief, all statements and information in this report are true and correct.

Should any disagreement or dispute arise as a result of this inspection or report, it shall be decided by arbitration and shall be submitted for binding, non-appealable arbitration to the American Arbitration Association in accordance with its Construction Industry Arbitration Rules then obtaining, unless the parties mutually agree otherwise. In the event of a claim, the Client will allow the Inspection Company to inspect the claim prior to any repairs or waive the right to make the claim. Client agrees not to disturb or repair or have repaired anything which may constitute evidence relating to the complaint, except in the case of an emergency.