Summary

Client(s):  John Doe
Property address:  123 main Street
Newtown, N.C. 13579
Inspection date:  Thursday, March 19, 2020

This report published on Tuesday, March 31, 2020 12:33:38 AM EDT

This summary page is not the entire report. The complete report may include additional information of interest or concern to you. It is strongly recommended that you promptly read the the complete report. For information regarding the negotiability of any item in this report under the real estate purchase contract, contact your North Carolina real estate agent or an attorney.

Concerns are shown and sorted according to these types:
Concern typeSafetyPoses a safety hazard
Concern typeMajor DefectCorrection likely involves a significant expense
Concern typeRepair/ReplaceRecommend repairing or replacing
Concern typeRepair/MaintainRecommend repair and/or maintenance
Concern typeMaintainRecommend ongoing maintenance
Concern typeEvaluateRecommend evaluation by a specialist
Concern typeMonitorRecommend monitoring in the future
Concern typeCommentFor your information


General Information
1) Structures built prior to the mid 1980s may contain lead and/or asbestos. Lead is commonly found in paint and in some plumbing components. The EPA does not recognize newer coats of paint as encapsulating older coats of lead-based paint. Asbestos is commonly found in various building materials such as insulation, siding, and/or floor and ceiling tiles. Laws were passed in 1978 to prohibit usage of lead and asbestos, but stocks of materials containing these substances remained in use for a number of years thereafter. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is beyond the scope of this inspection. Any mention of these materials in this report is made as a courtesy only, and meant to refer the client to a specialist. Consult with specialists as necessary, such as industrial hygienists, professional labs and/or abatement specialists for this type of evaluation. For information on lead, asbestos and other hazardous materials in homes call me and I can put you in contact with the proper organizations.
Paul 201-264-6294
2) Many areas and items at this property were obscured by furniture and/or stored items. This often includes but is not limited to walls, floors, windows, inside and under cabinets, under sinks, on counter tops, in closets, behind window coverings, under rugs or carpets, and under or behind furniture. Areas around the exterior, under the structure, in the garage and in the attic may also be obscured by stored items. The inspector in general does not move personal belongings, furnishings, carpets or appliances. When furnishings, stored items or debris are present, all areas or items that are obscured, concealed or not readily accessible are excluded from the inspection. The client should be aware that when furnishings, stored items or debris are eventually moved, damage or problems that were not noted during the inspection may be found.

Grounds
3) Soil was in contact with one or more wooden deck, porch support posts. This is a conducive condition for wood destroying organisms. Even if posts are made of treated wood, the cut ends below soil may not have been field treated. Recommend consulting a contractor to make necessary repairs or corrections.
4) Wooden deck or porch surfaces were overdue for normal maintenance. Recommend that a qualified person clean and preserve as necessary. Where decks have been coated with a finish such as opaque stains or paint, it may be too difficult to strip the finish and apply anything but paint or opaque stain. Where transparent stain or penetrating oil has been applied in the past, recommend that a professional contractor be consulted to make necessary repairs, corrections For more information, visit:
https://www.reporthost.com/?PENOIL
https://www.reporthost.com/?DKMAIN
Photo
Photo 4-1 This photo and the next show deck in need of maintenance on its surface and stairs. If left in current condition, further erosion and decay could occur. Recommend consulting a licensed contractor to make necessary repairs/corrections as needed. Also, see line item #3 above.
Photo
Photo 4-2 See line item #4 above.

Exterior and Foundation
5) The masonry brick veneer extended below the soil at all exterior walls. Masonry veneers should be installed so the bottom edge is at least a four inches above the soil so that any water accumulated inside the wall structure can drain from weep holes, and so termites don't enter the structure through mortar joints or cracks in the veneer. If soil, decorative bark, etc. has been back-filled against the veneer, it should be graded or removed as necessary to expose weep holes (if they're installed) and to maintain four inches of clearance between the veneer and the soil below. Otherwise, the client should at least be aware of this potential for water and insect intrusion, and monitor these walls inside and out for any signs of accumulated moisture in the future. See photos of exterior areas. If damage occurs, recommend that a qualified contractor repair as necessary. For more information, visit:
https://www.reporthost.com/?MVBG
Photo
Photo 5-1 Arrows show where soil makes contact with the brick veneer. Read statement no.5 above.

Roof
7) Extensions such as splash blocks or drain pipes for one or more downspouts were missing. (See photos) Water can accumulate around the building foundation or inside crawl spaces or basements as a result. Recommend that a qualified person install, replace or repair extensions as necessary so rainwater drains away from the structure.
Photo
Photo 7-1 Arrow indicates where an extension pipe can be installed to prevent water from causing damage to the brick surface, and to prevent water accumulation in the crawlspace. Recommend installation of these extensions for reasons stated above on line item #7
Photo
Photo 7-2 

Garage or Carport
9) Appliances such as the water heater in garage are subject to damage from vehicles because no protective barrier was installed in front of them. This is a potential safety hazard for fire, shock, and water damage. A qualified contractor should install a barrier per standard building practices. For example, a steel post or specially made wood partition anchored in the concrete slab floor.
Photo
Photo 9-1 See statement above photo.
Photo
Photo 9-2 Fire label on garage door to house painted over.

Electric
10) One or more electric receptacles at the bedroom(s), kitchen, family room, dining room, living room, sunroom, recreation room, hallway(s) and/or laundry area had no visible arc fault circuit interrupter (AFCI) protection, or (GFCI) protection. This is a potential safety hazard. Recommend that a qualified electrician evaluate and install AFCI and GFCI protection as per standard building practices.
11) One or more circuit breakers in panel(s were "double tapped," where two or more wires were installed in the breaker's lug. Most breakers are designed for only one wire to be connected. This is a safety hazard since the lug bolt can tighten securely against one wire but leave other(s) loose. Arcing, sparks and fires can result. Recommend that a qualified electrician repair as necessary. For more information, visit:
https://www.reporthost.com/?DBLTAP
Photo
Photo 11-1 See statement above.
12) No permanently installed carbon monoxide alarms were found. This is a potential safety hazard. Some states and/or municipalities require CO alarms to be installed for new construction and/or for homes being sold. Recommend installing approved CO alarms outside of each separate sleeping area in the immediate vicinity of the bedrooms in accordance with the manufacturer's recommendations. For more information, visit:
https://www.reporthost.com/?COALRM
13) The legend for circuit breakers in the electrical panel are incomplete. This is a potential shock or fire hazard in the event of an emergency when power needs to be turned off. Recommend correcting the legend so it's accurate, complete and legible. Evaluation by a qualified electrician is necessary to prevent an electrical shock or injury.
Photo
Photo 13-1 
Photo
Photo 13-2 Incomplete ledgen on rear of electricial panel door.

Plumbing / Fuel Systems
14) One or more hose bibs appeared to be inoperable. No water flowed from the hose bib(s) when turned on. This may be due to a shut-off valve being turned off. Note that the inspector does not operate shut-off valves. Recommend consulting with the property owner about inoperable hose bibs, and if necessary have a qualified plumber make repairs.
Photo
Photo 14-1 Crossed fingers means hose bib (spigot) not operating due to valve being turned off at time of inspection.
15) Based on visible equipment or information provided to the inspector, the water supply to this property appeared to be from a private well used for irrigation, and other purposes, (NOT POTABLE) Private well water supplies are specialty systems and are excluded from this inspection. Comments in this report related to this system are made as a courtesy only and are not meant to be a substitute for a full evaluation by a qualified specialist. The inspector does not test private well water for contamination or pollutants, determine if the supply and/or flow are adequate, or provide an estimate for remaining life of well pumps, pressure tanks or equipment. Only visible and accessible components are evaluated. Recommend the following:
  • That a qualified well contractor fully evaluate the well, including a pump/flow test
  • That the well water be tested per the client's concerns (coliforms, pH, contaminants, etc.)
  • Research the well's history (how/when constructed, how/when maintained or repaired, past performance, past health issues)
  • Document the current well capacity and water quality for future reference
For more information, visit:
https://www.reporthost.com/?WELL
Photo
Photo 15-1 This structure contains the well pump housing and components not used for potable water, and are not inspected as a part of a residential inspection. Recommend having a qualified person test and maintain for proper use.
16) This valve in photo below is a secondary main shutoff valve in crawlspace.
Photo
Photo 16-1 

Water Heater
17) The drain line assembly for the water heater's temperature-pressure relief valve appeared to be made from PVC plastic components. This material is not rated for high temperature and pressure and poses a safety hazard. A qualified plumber should repair per standard building practices.
Photo
Photo 17-1 Arrow points to the TPR valve drain pipe (temperature relief valve) made of pvc not designed for this purpose due to plastic pipe melting if water is released from the tank when under hot and high temperatures pressure. Injury or scalding can occur. Recommend hiring a licensed plumber to make necessary repairs/corrections.
18) The water heater was installed in an unheated space on a concrete floor and was not resting on an insulated pad or catch pan. The bottom of the casing is likely to rust, and energy efficiency may be reduced, and flooding may occur. Recommend consulting a licensed plumber for installing an insulated pad/catch pan under the water heater.
Photo
Photo 18-1 Read statement above.

Heating, Ventilation and Air Condition (HVAC)
19) The estimated useful life for most heat pumps and air conditioning condensing units is 10-15 years. This unit appeared to be at this age and/or its useful lifespan and may need replacing or significant repairs at any time. Recommend budgeting for a replacement in the near future.
20) One or more heating or cooling ducts have come apart, or had significant gaps at junctions. This can result in reduced energy efficiency and increased moisture in surrounding spaces. Recommend that a qualified HVAC contractor make repairs as necessary. For example, by securely supporting ducts and installing approved tape or mastic at seams, also replacing all filters.
Photo
Photo 20-1 See statement above.
21) The last service date of this heating/cooling system (heat pump) appeared to be more than 1 year ago. The inspector was unable to determine the last service date. Ask the property owner when it was last serviced, If unable to determine the last service date, or if this system was serviced more than 1 year ago, recommend that a qualified HVAC contractor service this system and make repairs/corrections to maintain proper function and efficiency. Because this system has a compressor and refrigerant system, this servicing should be performed annually in the future.

Fireplaces, Stoves, Chimneys and Flues
22) A converted wood burning fireplace into a gas log fireplace was located in the living room. When such devices are used, they should be professionally inspected and cleaned annually to prevent creosote build-up and to determine if repairs are needed. The National Fire Protection Association states that a "Level 2" chimney inspection should be performed with every sale or transfer of property with a wood-burning device. Recommend consulting with the property owner about recent and past servicing and repairs to all wood-burning devices and chimneys or flues at this property. Recommend that a qualified specialist evaluate all wood-burning devices and chimneys, and clean and repair as necessary. For more information, search for "chimney inspection" at:
https://www.reporthost.com/?CSIA
Photo
Photo 22-1 This fireplace apparently has not been used due to no burn or scorch marks. However, a thorough examination should be made before use for safety reasons. Arrows point to efflorescence or moisture possibly leaking through the flashing around the exposed chimney section on the roof. See photo above.
Photo
Photo 22-2 No corrosion or sediment build-up on flue damper from lack of use at yellow arrow. Red arrow show signs of rust which could mean moisture/water entering through the chimney also. Read item #21 above photo.
Photo
Photo 22-3 This photo and the next we can see a wood burning fireplace converted into a gas log fireplace. Recommend having this fireplace further evaluated for proper functioning and safety.
Photo
Photo 22-4 Propane gas shut-off valve at arrow with gas flames noted at time of inspection.
23) Recommend that the client review all available documentation for gas-fired fireplaces and stoves. Depending on how they are operated (for routine heating versus ambiance), such appliances may need servicing annually or every few years. Consult with the property owner and/or a qualified specialist to determine if service is needed now. Any needed repairs noted in this report should be brought to the attention of the specialist when it's serviced. For more information visit:
https://www.reporthost.com/?ANGFINSP

Bathrooms, Laundry and Sinks
25) The toilet in the second bathroom was loose where it attached to the floor. Leaks can occur. the Flooring, the sub-floor, and areas below may get damaged, and sewer gases can enter living spaces Recommend that a qualified contractor repair/replace for proper function and safety of occupants.
Photo
Photo 25-1 See statement above.

Interior, Doors and Windows
27) The inspector was unable to verify that the glass used in one or more exterior doors was approved safety glass. Glazing that is not approved safety glass, located in areas subject to human impact, is a safety hazard. Standard building practices generally require that approved safety glass be used in swinging and sliding doors. Recommend a contractor further evaluate for safety concerns.
Photo
Photo 27-1 See statement above concerning safety glass.
28) One or more windows that were designed to open and close were difficult to open and close. Recommend that a qualified person repair windows as necessary so they open and close easily.
Photo
Photo 28-1 Some windows were found to be inoperable and unsafe due to connections where these strings were disconnected from point of origin behind the vinyl covering inside the jamb liner. If left in current condition, someone can be injured especially children. Recommend hiring a contractor to make needed repairs for emergency such as fire exiting, and for normal opening and closing by occupants.
Photo
Photo 28-2