This report published on Friday, May 8, 2020 7:30:54 PM EDT
INTRODUCTION to the Home Inspection Report. It is IMPORTANT to read this Introduction, as well as all other items in this report.
This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited. Except as otherwise required by law, the home inspector shall not deliver a home inspection report to any person other than the client(s) of the home inspector without the client's consent.
The Home Inspection is conducted within the Scope of the Maryland Home Inspector Minimum Standards of Practice. Refer to the Standards of Practice for the full scope and exclusions.
The following Disclosures are to be noted per Maryland regulation
(i) "An inspection is intended to assist in the evaluation of the overall condition of a building. The inspection is based on observation of the visible and apparent condition of the building and its components on the date of the inspection";
(ii) "The results of this home inspection are not intended to make any representation regarding latent or concealed defects that may exist, and no warranty or guaranty is expressed or implied";
(iii) "Your home inspector is not a licensed structural engineer or other professional whose license authorizes the rendering of an opinion as to structural integrity of a building or the condition of its components or systems. You may wish to seek the professional opinion of a licensed structural engineer or other professional regarding any possible defects or other observations set forth in this report"; and
(iv) "Only home inspections performed by Maryland licensed home inspectors will be recognized as a valid home inspection under a real estate contract".
How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
Safety
Poses a risk of injury or death
Repair/Replace
Recommend repairing or replacing
Repair/Maintain
Recommend repair and/or maintenance
Maintain
Recommend ongoing maintenance
Evaluate
Recommend evaluation by a specialist
Monitor
Recommend monitoring in the future
Serviceable
Item or component is in serviceable condition
Comment
For your information
Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp
2) There is some damaged siding on the rear of the home. Siding should be repaired/replaced as necessary.
Photo 2-1
3) There is a gap at the edge of the garage roof where it meets the wall structure. This may allow bird/vermin intrusion. This area should be repaired as necessary to close gap.
Photo 3-1
4) The screen on the kitchen exhaust vent is loose. Screen should be secured as necessary.
Photo 4-1
5) With the exception of the noted concerns, overall the Exterior appeared to be in satisfactory condition. GFCI receptacles operated as intended.
Roof inspection method: Viewed from ground with binoculars
Roof type: Cross gable
Roof covering: Asphalt or fiberglass composition shingles
Estimated age of roof: <1
Gutter & downspout material: Aluminum
Roof ventilation: Adequate
6) There were a few raised shingles on the rear of the roof. This is usually caused by nails that were not driven in far enough during the initial installation or sometimes by nails that have loosened and then raised. This may cause premature wear/damage to shingles and leaks may occur as a result. The roofing contractor should evaluate and make repairs as necessary, such as re-seating nails.
Photo 6-1
7) With the exception of the noted concern, no other problems were observed with the shingles or roof in general.
Photo 7-1 Photo 7-2
Photo 7-3 Photo 7-4
8) This inspection is not a guarantee that a roof leak will not occur in the future. Even a roof that appears to be in good, functional condition may leak under certain circumstances. This is not a warranty or guarantee of the roof system. Also, we do not inspect under upper roof coverings. Doing so may damage the roof covering or create a condition for wind damage. For a guarantee, a roof contracting company would have to perform a water-test and issue a roof certification.
9) The garage-house door doesn't close and latch via the force of the automatic closing device(s) (spring loaded hinges). This door is intended to prevent vehicle fumes from entering living spaces and to slow the spread of fire from the garage to living spaces. Recommend that adjustments be made as necessary to the spring loaded hinges, so that this door self closes and self latches.
Photo 9-1
10) There is no way to lock the manually operated vehicle door from the exterior. The clients may want to install a locking mechanism that can be operated from the exterior.
Photo 10-1 Photo 10-2
Photo 10-3
11) Appropriate fire rated surfaces and garage-house door are in place. Except for the noted concerns, overall the garage appeared to be in satisfactory condition.
Primary heating system energy source: Natural gas, Electric
Primary heat system type: Forced air, Heat pump, High efficiency
Primary A/C energy source: Electric
Primary Air conditioning type: Split system, Heat pump
Distribution system: Sheet metal ducts, Flexible ducts
Manufacturer: Goodman
Filter location: In return air duct below furnace, Behind return air grill
14) Condensation is dripping off of the condensate drain line in the attic. This does not appear to be a leak, but is condensation that is formed when the cold condensate going out through the drain meets the warm drain pipe.
Most of the moisture is being caught by the back up drain pan, but some water is dripping down the vertical drain above the particle board platform.
Recommend that the contractor make repairs to ensure that condensate does not drip onto the wood or ceiling.
Photo 14-1 Condensation dripping off of bottom of loop mostly falls into catch pan Photo 14-2
Photo 14-3 Condensation is also forming on vertical pipe that is above wood platform
15) Recommend that the filters for the heating/cooling systems be checked monthly, or per manufacturer's recommendations, and replaced or washed as necessary.
Photo 15-1 Photo 15-2
Photo 15-3
16) There was moisture in several areas around the furnace/air handler located in the basement. The carpet just outside of the door to the utility room was also wet.
There didn't appear to be any on-going leaks and whatever caused the moisture may be remedied. Recommend asking the contractor about this and ensure that carpet is dried.
Photo 16-1 Photo 16-2
17) The heating and cooling systems appeared to operate as intended at time of inspection.
Insulation material underneath floor above: Fiberglass roll or batt
Pier or support post material: Steel
Beam material: Steel
Floor structure above: Engineered wood joists
22) Trim is missing around the egress window. Trim should be installed where missing.
Photo 22-1
23) There are blemishes on walls in a number of areas and the escutcheon is missing around a sprinkler head. Blemishes should be repaired where necessary and the escutcheon installed.
Photo 23-1 Photo 23-2
Photo 23-3 Photo 23-4
Photo 23-5 Photo 23-6
Photo 23-7 Photo 23-8
Photo 23-9 Photo 23-10
24) Carpet is wet in front of the utility room. See comments in Heating/Cooling Section.
Photo 24-1
25) With the exception of the noted concerns, overall the basement appeared to be in satisfactory condition.
26) Tile is missing above the stove top. Tile should be installed where missing.
Photo 26-1
27) Trim is missing at the dishwasher. Trim should be installed as necessary.
Photo 27-1 Photo 27-2
28) It appears that water is not available at the dispenser on the refrigerator. Recommend installing water connection as necessary.
Photo 28-1
29) The sink, appliances and GFCI receptacles appeared to operate as intended at time of inspection. Overall, the kitchen appeared to be in satisfactory condition.
30) Some wall tile is missing in the master bathroom. Tile should be installed where missing.
Photo 30-1 Photo 30-2
31) Caulk is missing around the base of the bathtub spout in the basement bathroom. There are also gaps in the caulk along the tub, as well as gaps in the master shower.
Caulk should be applied where necessary to prevent water intrusion and damage to wall structures.
Photo 31-1 Photo 31-2
Photo 31-3
32) Toilets, sinks, tubs/showers and GFCI receptacles operated as intended at time of inspection. Functional water flow appeared to be satisfactory.
33) Several heating/cooling registers do not fit into their openings in the floor. Openings should be enlarged as necessary so that registers fit as intended.
Photo 33-1 Photo 33-2
Photo 33-3
34) The window to the right of the fireplace makes an excessively loud noise when it is opened and is difficult to open. Recommend that repairs be made as necessary so that window opens and closes as intended.
Photo 34-1
35) Screens should be installed where necessary.
Photo 35-1
36) Escutcheons are missing at several sprinkler heads. Escutcheon should be installed where necessary.
Photo 36-1 Photo 36-2
Photo 36-3 Gap along escutcheon should be closed Photo 36-4
37) There are blemishes on walls in a number of locations. Blemishes should be repaired and repainted where necessary.
Photo 37-1 Photo 37-2
Photo 37-3 Photo 37-4
Photo 37-5
38) With the exception of the noted concerns, overall the interior of the home appeared to be in satisfactory condition.
Photo 38-1 Photo 38-2
Photo 38-3 Photo 38-4
Photo 38-5 Photo 38-6
Photo 38-7 Photo 38-8
Photo 38-9 Photo 38-10
39) Shoe molding is missing on either side of the fireplace, and trim is missing in front of the fireplace hearth. Trim should be installed where necessary.
40) Ceiling insulation is less than its required depth in an area near the hatch, and along the air handler platform.
Insulation should be installed where necessary to bring it up to the required R rating.
Photo 40-1 Photo 40-2
Photo 40-3
41) With the exception of the noted concerns, no other problems were observed with the roof structure or the attic in general.
Photo 41-1 Photo 41-2
Photo 41-3 Photo 41-4
Photo 41-5 Photo 41-6