View as PDF

View report

Speed Quality Home Inspection (Certificate#9929730)

3564 Elk Horn Trl SW 
Atlanta GA 30349-8794
Inspector: Antonio Speed
Title picture

Summary
Unofficial version!

Client(s): Britt Walker
Property address: 355 Brook Dr
Sandy Springs GA 30328-2109
Inspection date: Saturday, April 8, 2023

This report published on Saturday, April 8, 2023 4:24:39 PM EDT

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

Concerns are shown and sorted according to these types:
Concern typeSafetyPoses a safety hazard
Concern typeMajor DefectCorrection likely involves a significant expense
Concern typeRepair/ReplaceRecommend repairing or replacing
Concern typeRepair/MaintainRecommend repair and/or maintenance
Concern typeMaintainRecommend ongoing maintenance
Concern typeEvaluateRecommend evaluation by a specialist
Concern typeMonitorRecommend monitoring in the future
Concern typeCommentFor your information

General Information
1)  Microbial growths were found at one or more locations in the basement. It is beyond the scope of this inspection to identify what substance or organism this staining is. However such staining is normally caused by excessively moist conditions, which in turn can be caused by plumbing or building envelope leaks and/or substandard ventilation. These conducive conditions should be corrected before making any attempts to remove or correct the staining. Normally affected materials such as drywall are removed, enclosed affected spaces are allowed to dry thoroughly, a mildewcide may be applied, and only then is drywall reinstalled. For evaluation and possible mitigation, consult with a qualified industrial hygienist or mold/moisture mitigation specialist. For more information, visit:
http://www.reporthost.com/?MOLDCDC
http://www.reporthost.com/?MOLDEPA
2)  Microbial growths were found at one or more locations in . It is beyond the scope of this inspection to identify what substance or organism this staining is. However such staining is normally caused by excessively moist conditions, which in turn can be caused by plumbing or building envelope leaks and/or substandard ventilation. These conducive conditions should be corrected before making any attempts to remove or correct the staining. Normally affected materials such as drywall are removed, enclosed affected spaces are allowed to dry thoroughly, a mildewcide may be applied, and only then is drywall reinstalled. For evaluation and possible mitigation, consult with a qualified industrial hygienist or mold/moisture mitigation specialist. For more information, visit:
http://www.reporthost.com/?MOLDCDC
http://www.reporthost.com/?MOLDEPA
Photo
Photo 2-1 Evidence of a prior leak. Mold and rot on boards should be replaced.
Photo
Photo 2-2 
Grounds
5)  Significant amounts of standing water or evidence of past accumulated water were found at one or more locations in the yard or landscaped areas, and no drain was visible. If evidence of past water was found (e.g. silt accumulation or staining), monitor these areas in the future during periods of heavy rain. If standing water exists, recommend that a qualified person repair as necessary. For example, installing one or more drains, or grading soil.
Photo
Photo 5-1 Standing water in yard should be redirected by grading of the yard or with drainage system.
6)  Soil was in contact with one or more wooden deck, porch or balcony support posts. This is a conducive condition for wood destroying organisms. Even if posts are made of treated wood, the cut ends below soil may not have been field treated. Recommend grading soil or repairing as necessary to prevent wood-soil contact.
Photo
Photo 6-1 Deck boards should be on top of concrete pilars.
Basement
7)  
Photo
Photo 7-1 Minor mortar cracking in joints should be repointed.
Photo
Photo 7-2 Water from ceiling hole on basement stairs.
Photo
Photo 7-3 Galvanized pipes are known to rust and leak.
Photo
Photo 7-4 Hole in basement stairway leaked water.
Exterior and Foundation
8)  One or more minor cracks (1/8 inch or less) were found in the foundation. These didn't appear to be a structural concern, but recommend sealing them to prevent water infiltration and monitor them in the future. Numerous products exist to seal such cracks including hydraulic cement, non-shrinking grout, resilient caulks and epoxy sealants.
9)  Vegetation such as trees, shrubs and/or vines was in contact with or close to the building exterior. Vegetation can serve as a pathway for wood-destroying insects and can retain moisture against the exterior after it rains. This is a conducive condition for wood-destroying organisms. Recommend pruning, moving or removing vegetation as necessary to maintain at least 6 inches of space between it and the building exterior. A 1-foot clearance is better.
Photo
Photo 9-1 Trees to close to building could allow pest, rodents, and debris to enter home.
Photo
Photo 9-2 
Electric
11)  Knob and tube wiring and/or related components at one or more locations was damaged or deteriorated. This is a potential fire and shock hazard. Recommend that a qualified electrician repair as necessary.
Photo
Photo 11-1 Outdated electrical panel should be upgraded.
Photo
Photo 11-2 
Photo
Photo 11-3 
Plumbing / Fuel Systems
13)  The main water service pipe material was made of galvanized steel. Based on the age of the building, the apparent age of the pipe and/or the low-flow condition of the water supply system, this service pipe may have significant corrosion or rust on the inside and need replacing. Replacing the service pipe can significantly increase flow to the water supply pipes. Recommend consulting with a qualified plumber about replacing the main service pipe. Note that this can be an expensive repair since excavation is typically required.
Photo
Photo 13-1 Galvanized pipes are known to rust and leak.
Photo
Photo 13-2 Galvanized exhaust pipes should be removed and upgraded.
14)  One or more leaks were found in pipes or fittings. A qualified plumber should evaluate and repair as necessary.
Roof
15)  The roof surface appeared to be near the end of its service life and will likely need replacing in the near future even if repairs are made now. Recommend discussing replacement options with a qualified contractor, and budgeting for a replacement roof surface in the near future. The client may also wish to consider having a qualified contractor attempt to issue a "5 year roof certificate."
16)  One or more gutters and/or downspouts were damaged. Rainwater can come in contact with the building exterior or accumulate around the building foundation as a result. This is a conducive condition for wood-destroying organisms. Recommend that a qualified person repair as necessary.
Photo
Photo 16-1 
Attic and Roof Structure
17)  One or more rafters in the roof structure were damaged or split. This may significantly weaken the roof structure. Recommend that a qualified contractor repair as necessary.
Photo
Photo 17-1 Some attic boards showed signs of moisture and rotting.
Photo
Photo 17-2 Attic access was barely accessible.